Plan Review Details - Permit 17090367
Plan Review Stops For Permit 17090367
Review Stop G GAS REVIEW
Rev No 2 Status F Date 2017-09-27 Cont ID  
Sent By thunt Date 2017-09-27 Time 15:06 Rev Time 0.00
Received By thunt Date 2017-09-27 Time 15:06 Sent To  
Notes
2017-09-27 15:07:499/27/17 2ND REVIEW DENIED
  
 1) REQUEST OF SIZING TABLE FOR EXISTING 55' OF P.E
 PIPING

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2017-09-20 Cont ID  
Sent By thunt Date 2017-09-20 Time 13:00 Rev Time 0.00
Received By thunt Date 2017-09-20 Time 13:00 Sent To  
Notes
2017-09-20 13:08:179/20/17 1ST REVIEW (GAS) DENIED
  
 1) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2014
 FBC-FUEL GAS CODE SEC.304.1, 614.5 (CLOTHES DRYERS) OR
 2014 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES
 DRYERS).
  
 2) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR DRYER TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND FBC-2014 FUEL GAS CODE
 SEC. 402.2, AND 301.3 OR 2014 FBC-RES. SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT
 SHALL BE ONSITE AT THE TIME OF INSPECTION. FGC
 SEC.305.1, FBC-RES. SEC.G2408.1.
  
 3) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE
 LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION
 AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN
 RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER
 HEATER SHALL COMPLY WITH THE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND
 DRAWN. WPB AMEND. TO FBC SEC. 107.2.1.
  
 4) ) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES
 USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE
 PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM
 THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE
 DESIGN OF THIS GAS SYSTEM. REFER TO THE 2014 FBC-FUEL
 GAS SECS. 401.4, 401.8 THRU 402.6.1 AND TABLES 402.4
 (1) THRU 402.4 (37) OR 2014 FBC-RES. SEC. G2412.4,
 G2412.8, G2413.1, G2413.2, & G2413.3.
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-09-27 Cont ID  
Sent By thunt Date 2017-09-27 Time 15:07 Rev Time 0.00
Received By thunt Date 2017-09-22 Time 14:00 Sent To  
Notes
2017-09-25 14:00:52RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-09-20 Cont ID  
Sent By thunt Date 2017-09-20 Time 13:09 Rev Time 0.00
Received By thunt Date 2017-09-19 Time 18:39 Sent To  
Notes
2017-09-19 18:40:18PLUMB -$5000