Plan Review Details - Permit 17090352
Plan Review Stops For Permit 17090352
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-11-09 Cont ID  
Sent By cthroop Date 2017-11-09 Time 13:42 Rev Time 0.00
Received By cthroop Date 2017-11-09 Time 13:37 Sent To E
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-06 Cont ID  
Sent By cthroop Date 2017-10-06 Time 14:54 Rev Time 0.00
Received By cthroop Date 2017-10-06 Time 14:49 Sent To  
Notes
2017-10-06 14:59:22BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND
 THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON
 RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE.
  
 1. CANNOT READ PLANS.
 FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE,
 SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO
 RECORDS MANAGEMENT.
  
 2. PROVIDE DESIGN WIND LOADS.
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 3. PROVIDE DETAIL OF EXISTING EXTERIOR WALL.
 4. PROVIDE ATTACHMENT DETAIL FOR PROPOSED SIGN. INCLUDE
 FASTENER SCHEDULE.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-11-13 Cont ID  
Sent By jleahy Date 2017-11-13 Time 15:06 Rev Time 0.00
Received By jleahy Date 2017-11-13 Time 15:06 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-10-03 Cont ID  
Sent By jleahy Date 2017-10-03 Time 07:25 Rev Time 0.00
Received By jleahy Date 2017-10-03 Time 07:25 Sent To B
Notes
2017-10-03 07:26:16ADDRESS ZONING COMMENTS FOR ELECTRICAL PASS JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-13 Cont ID  
Sent By jleahy Date 2017-11-13 Time 15:06 Rev Time 0.00
Received By jleahy Date 2017-10-31 Time 11:08 Sent To  
Notes
2017-11-01 11:08:15RESUB ROUTED TO AJONES VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-06 Cont ID  
Sent By cthroop Date 2017-10-06 Time 14:53 Rev Time 0.00
Received By cthroop Date 2017-09-18 Time 16:07 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-11-07 Cont ID  
Sent By ajones Date 2017-11-07 Time 16:46 Rev Time 0.00
Received By ajones Date 2017-11-01 Time 15:10 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-09-29 Cont ID  
Sent By cthroop Date 2017-10-06 Time 14:53 Rev Time 0.00
Received By ajones Date 2017-09-29 Time 14:01 Sent To E
Notes
2017-09-29 14:03:189/29/17- DENIED- NEED LANDLORD APPROVAL LETTER OR
 STAMPED PLANS.
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]
2017-09-20 15:45:21ROUTED TO ANGELLA JONES VANN