Plan Review Details - Permit 17090196
Plan Review Stops For Permit 17090196 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2017-11-17 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2017-11-17 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-09-22 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-09-22 |
Time |
16:06 |
Sent To |
|
|
Notes |
2017-09-22 16:33:03 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | FS481. | | | | 2. TWO COMPLETE SETS OF PERMIT DOCUMENTS REQUIRED, FBC | | 107. | | | | 3. TITLE BLOCK STATES THIS IS A "CUSTOM RESIDENCE"; | | THIS DOES NOT APPEAR TO BE CONSISTENT WITH THE WORK | | PROPOSED, REVISE. | | | | 4. MOST OF THE DETAILS ON SHEET A5 LACK NUMBERS, | | REVISE. REVISE THE PLAN TO SHOW WHERE THE SECTIONS OR | | DETAILS ARE APPLICABLE, FBC 107. | | | | 5. IS THE FACILITY AVAILABLE FOR RENT OR IS IT | | EXCLUSIVELY FOR USE BY MEMBERS OF THE TEMPLE? IT IS NOT | | CLEAR WHETHER OR NOT FBC ACCESSIBILITY IS APPLICABLE. | | REVISE PLAN TO CLARIFY; THIS MAY BE A STATEMENT ON THE | | PLAN. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-17 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-17 |
Time |
10:12 |
Sent To |
|
|
Notes |
2017-11-17 10:12:04 | FOLLOWING COMMENTS (2) ADDED TO PLAN AS PROVISO: | | | | 1. RISER DIAGRAM AND PANEL SCHEDULES PROVIDED SHOW THE | | HIGH LEG ON PHASE C. HIGH LEG IS REQUIRED TO BE ON | | PHASE B PER THE NEC. PROVIDE CORRECTION FOR RISER AND | | PANEL SCHEDULES. NEC 408.3(E) | | 2. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-22 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-22 |
Time |
15:21 |
Sent To |
|
|
Notes |
2017-09-22 15:21:18 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR | | PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM | | BONDING TERMINATION POINT. NEC 215.5, 230, 250.50, | | 250.94, 408.30; FBC 107.2.1 | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30 | | 4. PROVIDE GRAPH/CALCULATION OF INTERIOR LIGHTING POWER | | ALLOWANCES PER THE FBC ENERGY CODE IN RELATION TO THE | | CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH | | CODE. FBC CE 405.5 | | 5. PROVIDE THE ADDITIONAL LIGHTING CONTROLS STIPULATED | | IN THE FBC ENERGY CODE. PLAN DOES NOT SHOW ANY TYPE OF | | AUTOMATIC LIGHTING CONTROL REQUIRED BY THE ENERGY CODE. | | FBC CE 405.2.2, 405.2.2.2 | | 6. NOTE 12 OF GENERAL ELECTRICAL NOTES STATES THAT | | ROMEX MAY BE USED IN THIS INSTALLATION. PROVIDE DETAILS | | OF BUILDING TYPE TO COMPLY WITH PERMITTED INSTALLATIONS | | FOR ROMEX, OR REVISE NOTE. NEC 334.10, 12 | | 7. PROVIDE FIXTURE SCHEDULE AND LEGEND. FBC 107.2.1; | | NEC 110.3 | | 8. PROVIDE 2 COPIES OF PLAN FOR REVIEW, PROVIDE CORRECT | | ADDRESS ON PLANS FOR PROJECT, PROVIDE PROPER SIGNATURE | | AND SEAL PER FS 471. FS 471.003(2)(H); 471.025; FBC | | 107.2.1 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-11-07 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-11-07 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-11-07 |
Time |
12:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-09-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-09-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-09-14 |
Time |
11:52 |
Sent To |
|
|
Notes |
2017-09-14 14:13:24 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS NO ADDRESS ON THE TILTE BLOCK AND THERE IS | | WORDING INDICATING TEMPLE BETH EL, MARTIN COUNTY, | | FLORIDA. | | | | PLEASE PROVIDE THE CORRECT ADDRESS WITHIN THE TITLE | | BLOCK | | | | | | | | 2) THERE IS ONLY ONE SET OF PLANS SUBMITTED. | | | | PLEASE PROVIDE AT LEAST ONE ADDITIONAL SET. | | | | | | | | 3) THERE IS NO INDICATION OF COMPLIANCE WITH ANY FIRE | | CODE. | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | APPLICABLE CODES OR STANDARDS. | | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 13, 2010 EDITION. | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 72, 2010 EDITION. | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 241, 2009 EDITION. | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 10, 2010 EDITION. | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | PLEASE ENSURE COMPLIANCE AND PROVIDE THE APPLICABLE | | NOTES. | | | | | | | | 4) THERE ARE NO INDICATIONS OF ANY FIRE SPRINKLER OR | | FIRE ALARM SYSTEMS. | | | | PLEASE PROVIDE INDICATING NOTES. | | | | ALL FIRE SPRINKLER AND FIRE ALARM WORK SHALL BE DONE | | UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | CONTRACTORS. | | | | | | | | 5) NEW DOORS ARE INDICATED; HOWEVER, THERE IS NOT DOOR | | SCHEDULE. | | | | PLEASE PROVIDE A DOOR SCHEDULE INCLUDING HARDWARE. | | | | | | | | 6) NEW WALLS ARE INDICATED; HOWEVER, THERE IS NO | | INDICATOR OF WHAT WALL TYPE IS BEING USED. | | | | PLEASE CORRECT. | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-11-17 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2017-11-17 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2017-11-03 |
Time |
13:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-09-22 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-09-07 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-11-13 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-11-13 |
Time |
15:34 |
Sent To |
|
|
Notes |
2017-11-13 16:13:04 | THE ARCHITECT OF RECORD IS STATING IN HIS RESPONSE | | NARRATIVE TO THE 1ST REVIEW COMMENTS THAT NO MECHANICAL | | ALTERATIONS WILL BE DONE ON THE PROJECT. | | BASED ON THAT RESPONSE, A SEPARATE PERMIT AND PLANS | | SHALL BE SUBMITTED FOR ANY MECHANICAL WORK THAT OCCURS | | ON THE PROJECT. | | CCOLE- 11/13/17 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-09-22 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-09-22 |
Time |
09:58 |
Sent To |
|
|
Notes |
2017-09-22 10:08:28 | 1ST REVIEW FBC-2014 MECHANICAL , EXISTING BUILDING | | CODES | | PERMIT #17090196 | | 9/122/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE MECHANICAL PLANS SHOWING ALL REQUIRED | | ALTERATIONS TO THE SYSTEMS TO ACCOMODATE THE FLOOR PLAN | | CHANGES. | | | | 2) THE ARCHITECT SHALL PROVIDE ORIGINAL SEALS AND | | SIGNATURES TO THE PLANS- SECTION 61G15- 16.003 FLORIDA | | AMINISTRATIVE CODE. | | | | 3) A MINIMUM OF TWO SETS OF PLANS ARE REQUIRED PER | | SECTION 107.2.1 WPB AMENDMENTS TO THE FBC. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
|