Plan Review Details - Permit 17090058
Plan Review Stops For Permit 17090058
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-07-10 Cont ID  
Sent By rgathrig Date 2018-07-10 Time 11:34 Rev Time 0.00
Received By rgathrig Date   Time   Sent To  
Notes
2018-07-10 11:34:20PROVISO FOR SOUND TRANSMISSION TEST VERIFICATION WAS
 SUBMITTED/APPROVED UNDER 17110020 (REG)

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-10-24 Cont ID  
Sent By shill Date 2017-10-24 Time 15:16 Rev Time 0.00
Received By shill Date 2017-10-24 Time 15:11 Sent To  
Notes
2017-10-24 15:17:05PROVISO: STC,IIC, FLAME SPREAD TESTS FOR FLOORING
 UNDERLAYMENT REQUIRED TO BE SUBMITTED AND REVIEWED
 PRIOR TO INSTALLATION
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-09-29 Cont ID  
Sent By jwitmer Date 2017-09-29 Time 16:48 Rev Time 0.00
Received By shill Date 2017-09-29 Time 16:48 Sent To  
Notes
2017-09-29 16:52:21****CORRECTIONS****
  
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 FBC A FAIR HOUSING CHAPTER, THIS PROJECT IS SUBJECT TO
 FAIR HOUSING REQUIREMENTS.
  
 1. SHEET A2-90-15B. REVISE PLAN TO CLARIFY CLEAR
 OPENING WIDTH FOR THE NEW DOORS. FAIR HOUSING REQUIRES
 A CLEAR WIDTH OF 32 INCHES. 2014 FBC- ACCESSIBILITY/
 FAIR HOUSING SECTION 100.205.(C)(2)(2).
  
 FOR POCKET DOORS - IF THE CLEAR OPENING WIDTH IS 32" OR
 LESS WITH THE DOOR IN THE FULLY RECESSED POSITION, IT
 APPEARS THAT THIS DOES NOT PROVIDE SOMEONE WHO NEEDS
 ACCESSIBLE HARDWARE THE ABILITY TO USE THE DOOR AND
 MAINTAIN THE 32" CLEARANCE (SEE USABLE DOORS, FIGURE
 1). IF SUCH HARDWARE IS AVAILABLE AND USABLE WITH THE
 DOOR IN THE FULLY OPEN POSITION, PLEASE SEND
 INFORMATION VIA EMAIL FOR PRELIMINARY REVIEW.
  
 PER BUILDING OFFICIAL: IF A POCKET DOOR CAN BE
 RETROFITTED WITH A SWING DOOR WHICH COMPLIES WITH THE
 32" CLEARANCE, AND A SWING DOOR CAN BE INSTALLED IN THE
 FUTURE IN THAT LOCATION (ENOUGH SPACE), THAT OPTION
 WOULD BE ACCEPTED. THE INTENT IS THAT AN OCCUPANT HAS
 AN ACCESSIBLE ROUTE THROUGHOUT THE UNIT WITHOUT MAJOR
 CONSTRUCTION (MOVING WALLS, REFRAMING DOOR OPENINGS).
 IF A POCKET DOOR CAN BE ADAPTED WITH A DOOR CHANGE,
 THAT IS ACCEPTABLE. IF YOU WISH TO DISCUSS, PLEASE FEEL
 FREE TO CONTACT ME.
  
 IT APPEARS THAT THE DOORS AT THE SHOE CLOSET AND CLOSET
 MEET THE 32" CLEARANCE REQUIREMENT, BUT DOOR U05V
 APPEARS TO BE 32".
  
 2. PROVIDE THE FOLLOWING TEST REPORTS FOR THE FLOORING
 UNDERLAYMENT:
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-11-06 Cont ID  
Sent By jleahy Date 2017-11-06 Time 08:54 Rev Time 0.00
Received By jleahy Date 2017-11-06 Time 08:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-09-25 Cont ID  
Sent By jleahy Date 2017-09-25 Time 08:58 Rev Time 0.00
Received By jleahy Date 2017-09-25 Time 08:58 Sent To  
Notes
2017-09-25 08:59:52FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 PLAN DOES NOT SHOW CLOUDS FOR REVISIONS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-09-15 Cont ID  
Sent By pleduc Date 2017-09-15 Time   Rev Time 0.00
Received By pleduc Date 2017-09-14 Time 16:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-06 Cont ID  
Sent By jleahy Date 2017-11-06 Time 08:54 Rev Time 0.00
Received By jleahy Date 2017-10-17 Time 12:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-03 Cont ID  
Sent By lmarchan Date 2017-10-03 Time 11:26 Rev Time 0.00
Received By lmarchan Date 2017-09-06 Time 10:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-11-01 Cont ID  
Sent By ccole Date 2017-11-01 Time 16:14 Rev Time 0.00
Received By ccole Date 2017-11-01 Time 16:13 Sent To  
Notes
2017-11-01 16:15:36MECHANICAL PROVISO:
 PRIOR TO ISSUANCE OF CO, THE DESIGN PROFESSIONAL OF
 RECORD SHALL CERTIFY THE APPLICATION OF THE INTUMESCENT
 PAINT ON THE AC CLOSET DOORS.
 11/1/17
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-09-22 Cont ID  
Sent By ccole Date 2017-09-22 Time 17:34 Rev Time 0.00
Received By ccole Date 2017-09-22 Time 17:32 Sent To  
Notes
2017-09-22 17:37:481ST REVIEW FBC-2014 MECHANICAL, WPB AMENDMENTS TO THE
 FBC.
 REVISION #17090058
 MASTER PERMIT #15111020
 THE BRISTOL
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE AC CLOSET DOORS UO5G, UO5H, & UO5K MUST BE
 NON-COMBUSTIBLE- SECTION 602.2.1. THE DOOR SCHEDULE ON
 THE MASTER SHEET A8.12 INDICATES WOOD DOORS.
  
 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR THE
 COOKING APPLIANCE IN THE KITCHEN AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS WITH APPROVAL STAMP AND
 SIGNATURE BY THE EOR- SECTION 623.1- 623.5 FBC-14 FUEL
 GAS.
  
 3) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR THE
 EXHAUST VENTILATION HOOD AND EXHAUST DUCT, AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS WITH APPROVAL STAMP AND
 SIGNATURE BY THE EOR- SECTIONS 505.1 AND 505.2.
  
 4) SHEET M2.90-15B: PLEASE LABEL THE ROOMS ON THE
 REVISED PLAN.
  
 5) SHOW THE LOCATIONS OF THE RETURN OPENINGS AT THE
 PERIMETER COVES AND PROVIDE A DETAIL. PLEASE NOTE THAT
 ALL AIR SUPPLIED TO A MASTER SUITE MUST BE RETURNED-
 SECTION 601.5 (3).
  
 6) PROVIDE SUBDUCT INSTALLATION DETAILS.
  
 7) THE UPLOADED NARRATIVE STATES "REMOVED EXHAUST
 FANS". PLEASE CLARIFY WHICH EXHAUST FANS HAVE BEEN
 REMOVED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-10-03 Cont ID  
Sent By gjohnson Date 2017-10-03 Time 10:18 Rev Time 0.00
Received By gjohnson Date 2017-10-03 Time 10:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-09-26 Cont ID  
Sent By jroach Date 2017-09-26 Time 09:09 Rev Time 0.00
Received By jroach Date 2017-09-26 Time 09:09 Sent To  
Notes
***NONE***