Plan Review Details - Permit 17081437
Plan Review Stops For Permit 17081437 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-10-02 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2017-10-02 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2017-10-02 |
Time |
09:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-09-18 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2017-09-18 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2017-09-18 |
Time |
10:37 |
Sent To |
|
|
Notes |
2017-09-18 11:00:33 | ****PLAN REVIEW COMMENTS**** | | | | ART LANGE - BUILDING INSPECTOR | | 561-805-6667 [email protected] | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | RESIDENTIAL CODE 2015 5TH EDITION | | | | 1. PROVIDE TWO COPIES OF PRODUCT APPROVALS FOR THE | | CASEMENT WINDOWS AT OPENINGS 18, 19, 21 AND 22. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | SUBMITTALS. | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-22 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-22 |
Time |
13:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-10-02 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2017-10-02 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2017-09-25 |
Time |
14:02 |
Sent To |
|
|
Notes |
2017-09-26 14:02:44 | RESUB ROUTED TO ACLANGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-22 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-30 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-09-22 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-09-20 |
Time |
15:58 |
Sent To |
|
|
Notes |
2017-09-22 12:25:50 | PROVISO APPROVAL | | | | MIN 21" REQUIRED IN FRONT OF THE TOILET AND SINK FBC-P | | 405.3.1 |
|
|
|