Plan Review Details - Permit 17081402
Plan Review Stops For Permit 17081402
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-11-06 Cont ID  
Sent By cthroop Date 2017-11-06 Time 09:33 Rev Time 0.00
Received By cthroop Date 2017-11-06 Time 09:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-09-29 Cont ID  
Sent By cthroop Date 2017-09-29 Time 14:04 Rev Time 0.00
Received By cthroop Date 2017-09-29 Time 11:04 Sent To  
Notes
2017-09-29 14:21:21BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGN PROFESSIONAL TO SUBMIT PLANS WITH ORIGINAL
 SIGNATURE AND SEAL PER CHPT. 481.321 F.S. & 61G1 FAC.
 2ND REQUEST.
 2. CANNOT VERIFY IF THE WATER FEATURE IS A POOL OR
 FOUNTAIN. PROVIDE POOL/FOUNTAIN ENGINEER DRAWINGS PER
 NOTE #1, PLAN PAGE L1 TO VERIFY WATER DEPTH.
 3. IF DEPTH OF WATER IN WATER FEATURE EXCEEDS 24
 INCHES, FENCE SHALL COMPLY WITH THE REQUIREMENTS OF A
 POOL BARRIER. PLEASE ADVISE.
  
 FBC107.1 GENERAL. THE CONSTRUCTION DOCUMENTS SHALL BE
 PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE
 REQUIRED BY CHAPTER 471, FLORIDA STATUTES& 61G15
 FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA
 STATUTES& 61G1 FLORIDA ADMINISTRATIVE CODE.
  
 (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE
 LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE
 SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR
 COPIED IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE
 USED.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-09-07 Cont ID  
Sent By cthroop Date 2017-09-07 Time 11:10 Rev Time 0.00
Received By cthroop Date 2017-09-07 Time 10:51 Sent To  
Notes
2017-09-07 11:19:26BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGN PROFESSIONALS SIGNATURE AND SEAL MUST BE
 ORIGINAL.
 2. WALL WILL BE USED AS A POOL BARRIER. BARRIER MUST
 COMPLY WITH R4501.17.
 3. GATES MUST COMPLY WITH R4501.17.1.8.
 4. WALL FOOTING CANNOT ENCROACH ONTO ADJACENT PROPERTY.
  
 (1) ONLY THE FOLLOWING SEALS ARE AUTHORIZED TO BE USED
 PURSUANT TO FLORIDA STATUTES ? 471.025;
 (A) WET SEALS: A WET SEAL IS ANY SEAL PHYSICALLY
 APPLIED TO A PRINTED DOCUMENT CAPABLE OF LEAVING A
 PERMANENT INK REPRESENTATION OR OTHER FORM OF OPAQUE
 PERMANENT IMPRESSION ON THE PRINTED DOCUMENT THAT
 COMPLIES WITH SUBSECTION 61G15-23.002(2), F.A.C.;
 (B) EMBOSSING SEALS: AN EMBOSSING SEAL IS ANY SEAL
 PHYSICALLY APPLIED TO A PRINTED DOCUMENT CAPABLE OF
 LEAVING A PERMANENT CRIMPED REPRESENTATION OR OTHER
 FORM OF PERMANENT RAISED IMPRESSION ON THE PRINTED
 DOCUMENT THAT COMPLIES WITH SUBSECTION 61G15-23.002(2),
 F.A.C.; OR
 (C) DIGITALLY CREATED SEALS: A DIGITALLY CREATED SEAL
 IS ANY SEAL CREATED AS PART OF THE DOCUMENT AND NOT
 PHYSICALLY APPLIED THAT IS AN OPAQUE PERMANENT
 REPRESENTATION THAT COMPLIES WITH SUBSECTION
 61G15-23.002(2), F.A.C.
  
 R4502.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER
 COMPLYING WITH SECTIONS R4501.17.1.1 THROUGH
 R4501.17.1.14.
  
 R4501.17.1.8
 ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND
 SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS
 R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED
 WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL
 SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED
 NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE
 GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON
 EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE
 REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY
 OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE
 ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM
 THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING
 GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457
 MM) OF THE RELEASE MECHANISM.
  
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2017-09-27 Cont ID  
Sent By destabro Date 2017-09-27 Time 16:57 Rev Time 0.00
Received By destabro Date 2017-09-27 Time 16:57 Sent To B
Notes
2017-09-27 16:58:139/27/2017 - CONDITIONAL APPROVAL REMAINS. REAR
 ACCESSORY STRUCTURE SHOULD HAVE APPLIED GARAGE/CARRIAGE
 STYLE DOORS. THIS IS NOT EVIDENCED IN THE CURERNT
 FLOORPLAN. DLE

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-09-01 Cont ID  
Sent By destabro Date 2017-09-01 Time 12:27 Rev Time 0.00
Received By destabro Date 2017-09-01 Time 12:27 Sent To Z
Notes
2017-09-01 12:28:349/1/2017 - CONDITIONAL APPROVAL - PLANS SHOULD REFLECT
 APPLICATION OF MOUNTED GARAGE DOORS TO ACCESSORY
 STRUCTURE. OTHER PROPOSED STRUCTURAL ELEMENTS MEET
 DESIGN GUIDELINES OF THE HISTORIC DISTRICT. DLE
2017-09-01 10:56:03ROUTED TO DESIREE ESTABROOK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-11-06 Cont ID  
Sent By cthroop Date 2017-11-06 Time 09:33 Rev Time 0.00
Received By cthroop Date 2017-10-23 Time 10:55 Sent To I
Notes
2017-10-24 10:55:32RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-09-29 Cont ID  
Sent By cthroop Date 2017-09-29 Time 14:04 Rev Time 0.00
Received By cthroop Date 2017-09-20 Time 10:34 Sent To  
Notes
2017-09-22 10:34:44RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-09-07 Cont ID  
Sent By cthroop Date 2017-09-07 Time 11:10 Rev Time 0.00
Received By cthroop Date 2017-08-30 Time 14:14 Sent To  
Notes
2017-08-31 14:14:23ROUTED TO HISTORIC VIA ZONING INBOX

Review Stop Z ZONING
Rev No 3 Status P Date 2017-11-02 Cont ID  
Sent By DE Date 2017-11-02 Time 10:18 Rev Time 0.00
Received By destabro Date 2017-11-02 Time 10:18 Sent To B
Notes
2017-11-02 10:20:2511/2/2017 - PARTIAL GRAVEL YARD INFILL IS BEHIND
 PRIVACY WALL AND ADDITIONALLY IS CONTAINED WITHIN SIDE
 EDGING AND A PAVER DRIVEWAY CONNECTION TO THE ROAD. DLE

Review Stop Z ZONING
Rev No 2 Status P Date 2017-09-25 Cont ID  
Sent By njwira Date 2017-09-25 Time 16:53 Rev Time 0.00
Received By njwira Date 2017-09-22 Time 15:57 Sent To HIST
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-09-01 Cont ID  
Sent By njwira Date 2017-09-01 Time 14:36 Rev Time 0.00
Received By njwira Date 2017-09-01 Time 14:36 Sent To B
Notes
2017-09-01 14:39:309/1/17- FAILED
  
 94-304(D)- POOL CANNOT BE IN THE FRONT 25FT. SETBACL
 94-482(A)- MUST PROVIDE 1,000SQFT. OF PERVIOUS SURFACE
 WHAT IS THE DIMENSIONS OF THE PROPERTY
 WHAT IS THE HEIGHT OF THE LIGHTING?
  
  
 PLEASE CONTACT
 NATHAN WIRA- ZONING TECHNICIAN
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING
 DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST.
 WEST PALM BEACH, FL 33402
 OFFICE HOURS: M-F 8AM - 5PM
 (561)822-1442
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved