Plan Review Details - Permit 17081319
Plan Review Stops For Permit 17081319
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-09-15 Cont ID  
Sent By aclange Date 2017-09-15 Time 10:50 Rev Time 0.00
Received By aclange Date 2017-09-15 Time 10:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-10-02 Cont ID  
Sent By jpearson Date 2017-10-02 Time 14:42 Rev Time 0.00
Received By jpearson Date 2017-10-02 Time 14:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-09-11 Cont ID  
Sent By jpearson Date 2017-09-11 Time 14:52 Rev Time 0.00
Received By jpearson Date 2017-09-11 Time 14:52 Sent To  
Notes
2017-09-11 14:52:34CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ON THE RISER DIAGRAM, THE CONDUIT FROM THE MAIN
 BREAKER PANEL TO THE INTERIOR PANEL IS REQUIRED TO HAVE
 AN EQUIPMENT GROUNDING CONDUCTOR. PROVIDE CORRECTION.
 NEC 250.122; FBC RE 3704.6
 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. NEC 250.94; FBC RE3609.3
 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC
 RE3706.2, RE3902
 4. PER CODE: "LIGHTING WITH OPEN OR PARTIALLY ENCLOSED
 LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT
 BE PERMITTED IN CLOTHES CLOSETS". CLOSETS ARE SHOWN
 WITH A STANDARD RECESS LIGHT. PROVIDE CORRECTION. NEC
 410.16; FBC RE4003.12
 5. THE WALL SPACING REQUIREMENTS FOR KITCHEN COUNTER
 SPACE STATE THAT RECEPTACLE OUTLETS SHALL BE INSTALLED
 SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24
 INCHES MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET
 IN THAT SPACE. THE PLAN PROVIDED DOES NOT MEET THIS
 CODE IN SOME AREAS. PROVIDE CORRECTION. NEC
 210.52(C)(1); FBC RE3901.4
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-02 Cont ID  
Sent By jpearson Date 2017-10-02 Time 14:42 Rev Time 0.00
Received By jpearson Date 2017-09-29 Time 12:50 Sent To  
Notes
2017-10-02 12:50:19RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-09-15 Cont ID  
Sent By aclange Date 2017-09-15 Time 10:50 Rev Time 0.00
Received By aclange Date 2017-08-28 Time 14:43 Sent To  
Notes
2017-08-29 14:43:34R17

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-09-14 Cont ID  
Sent By thunt Date 2017-09-14 Time 14:49 Rev Time 0.00
Received By thunt Date 2017-09-14 Time 14:01 Sent To  
Notes
2017-09-14 14:50:15SEPERATE PLUMBING BACKFLOW AND PERMIT REQUIRED FOR POOL
 AUTO FILL PER FBC-RES R4501.9