Plan Review Details - Permit 17081230
Plan Review Stops For Permit 17081230 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2017-09-06 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-09-06 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-09-06 |
Time |
07:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-10-03 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-03 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-10-03 |
Time |
08:27 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-13 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-13 |
Time |
13:00 |
Sent To |
|
|
Notes |
2017-09-13 13:00:38 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED | | SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | SUBMITTALS WHERE APPLICABLE FOR LOW VOLTAGE SYSTEMS, | | FIRE ALARM, CCTV, PHONE AND DATA, WIRELESS SYSTEMS, | | WALK-IN COOLERS, HOODS, ETC. FBC 105.1 | | 2. RECEPTACLE CONTROL INDICATED DOES NOT COVER ALL | | AREAS REQUIRED. PROVIDE CORRECTION TO INCLUDE CONTROL | | FOR AT LEAST 50% OF ALL 125-VOLT 15 AND 20 AMP | | RECEPTACLES IN ALL PRIVATE OFFICES, CONFERENCE ROOMS, | | ROOMS USED PRIMARILY FOR PRINTING AND/OR COPYING | | FUNCTIONS, BREAK ROOMS, CLASSROOMS, AND INDIVIDUAL | | WORKSTATIONS. FBC CE 405.7.1, ASHRAE 90.1:8.4.2 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2017-08-30 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-08-30 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-08-30 |
Time |
13:08 |
Sent To |
|
|
Notes |
2017-08-30 13:19:45 | REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE THE | | OWNER, CONTRACTOR, ETC. OF THE RESPONSIBILITY OF | | COMPLIANCE WITH CODE (NFPA 1, SECTION 1.14.4). FBC | | SECTION 105.4.1 PERMIT INTENT: A PERMIT ISSUED SHALL BE | | CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND | | NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE | | ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL | | ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM | | THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, | | CONSTRUCTION OR VIOLATIONS OF THIS CODE. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-10-05 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-09-29 |
Time |
13:55 |
Sent To |
|
|
Notes |
2017-10-02 13:55:51 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-09-19 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-08-25 |
Time |
09:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2017-09-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-09-14 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-09-14 |
Time |
12:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-10-05 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-10-05 |
Time |
06:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-09-19 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-09-19 |
Time |
11:58 |
Sent To |
|
|
Notes |
2017-09-19 12:32:27 | 1) THE SINK IN THE BREAK ROOM AND AT THE RECEPTION AREA | | SHALL COMPLY WITH THE 2014 FBC-ACCESS. SECS.212.3, 606. | | THE PLANS HAVE AN ELEVATION OF "ADA" SINK BUT IT IS | | SPECIFIED AS TO THE LOCATION OF THIS SINK.THE MAXIMUM | | HEIGHT FOR BOTH OF THESE SINKS SHALL BE 34 INCHES ABOVE | | FINISH FLOOR TO THE TOP OF THE COUNTER. | | 2) AIR ARRESTORS ARE REQUIRED ON THE DISHWASHER, WATER | | DISPENSER AND THE ICE MAKER PER THE 2014 FBC-PLUMBING | | SEC.604.9. | | 3) BACKFLOW PREVENTERS ARE REQUIRED ON THE COFFEE | | MACINE, WATER DISPENSER, AND ICEMAKER. 2014 FBC | | -PLUMBING SEC.608.3, 608.16.10. | | 4) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE EEMAX | | INSTANT WATER HEATERS. WPB AMEND. TO FBC SEC. 107.2.1. | | 5) SHT. P-001 - SHOW THE REQUIRED HEIGHT AND KNEE AND | | TOE CLEARANCES FOR THE HANDICAPPED ACCESSIBLE | | LAVATORIES PER THE 2014 FBC-ACCESS. SECS. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
|