Plan Review Stops For Permit 17081137 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-10-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-14 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-13 |
Time |
16:23 |
Sent To |
|
|
Notes |
2017-10-14 12:41:51 | PROVISO | | 1. FOUNDATION - CONTRACTOR TO PROVIDE DETAIL PER MANUF. | | INSTALLATION INSTRUCTIONS, SEE SEC. 3.2 (PG'S. 24 & | | 25). | | 2. EQUIPMENT PAD ELEVATION - DFE 8' 0". | | 3. ATTACHMENT DETAIL - CONTRACTOR TO SPECIFY ANCHORS | | PER SEC. 3.2.4 (PG 25) AND RED HEAD SUBMITTAL. | | 4. VIBRATION ISOLATORS - CONTRACTOR TO SELECT ISOLATOR | | TYPE PER SEC. 3.4 (PG'S 25 & 26). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-05 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-05 |
Time |
10:30 |
Sent To |
|
|
Notes |
2017-10-05 10:34:31 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED | | | | I HAVE COPIED THEM HERE FOR YOUR REFERENCE | | | | 1. GENERATOR RE-LOCATED PER REVISION # 17080723. | | 2. PROVIDE FOUNDATION DETAIL. | | 3. PROVIDE ATTACHMENT DETAIL. | | 4. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-08-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-08-24 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-08-24 |
Time |
14:09 |
Sent To |
E |
|
Notes |
2017-08-24 14:13:46 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. GENERATOR RE-LOCATED PER REVISION # 17080723. | | 2. PROVIDE FOUNDATION DETAIL. | | 3. PROVIDE ATTACHMENT DETAIL. | | 4. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-10-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-10-04 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-10-04 |
Time |
09:52 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-09-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-09-29 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-09-29 |
Time |
07:50 |
Sent To |
|
|
Notes |
2017-09-29 07:52:59 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-08-25 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-08-25 |
Time |
09:46 |
Sent To |
Z |
|
Notes |
2017-08-25 09:50:43 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | NEED TO SUBMIT A RISER DIAGRAM BLDG PLANS 16050108 | | SHOWS 400A GENERATOR, THE PAPER WORK SHOWS 600A | | | | PAPER WORK NOT CLEAR AS TO WHAT TYPE OF GENERATOR AND | | TRANSFER SWITCH IS BEING USED (SIZE) | | | | PLEASE CLARIFY WITH ONE LINE DIAGRAM OF THE RISER ALONG | | WITH WIRE SIZES AND DISCONNECT SIZES. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2017-09-01 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-09-01 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-09-01 |
Time |
09:58 |
Sent To |
B |
|
Notes |
2017-09-01 09:59:24 | 9/1/2017 - NOT UNDER PURVIEW OF DESIGN GUIDELINES FOR | | HISTORIC DISTRICTS. DLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-10-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-14 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-06 |
Time |
12:52 |
Sent To |
|
|
Notes |
2017-10-10 12:52:34 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-05 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-29 |
Time |
14:33 |
Sent To |
|
|
Notes |
2017-10-02 17:37:49 | SENT TO ZONING JLEAHY | 2017-09-29 14:33:40 | RESUB GIVEN TO JLEAHY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-09-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-09-29 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-09-19 |
Time |
15:53 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-09-05 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-09-05 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-08-23 |
Time |
11:27 |
Sent To |
|
|
Notes |
2017-08-24 11:27:53 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-10-13 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-10-13 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-10-11 |
Time |
16:52 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2017-10-03 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-10-03 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-10-03 |
Time |
09:05 |
Sent To |
E |
|
Notes |
2017-10-03 15:34:25 | 10/3/17- FAILED | | | | PLEASE INDICATE ON A SURVEY WHERE THE GENERATOR IS | | GOING. | | | | | | PLEASE CONTACT | | NATHAN WIRA- ZONING TECHNICIAN | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING | | DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST. | | WEST PALM BEACH, FL 33402 | | OFFICE HOURS: M-F 8AM - 5PM | | (561)822-1442 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-08-31 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-08-31 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-08-29 |
Time |
09:51 |
Sent To |
HIST |
|
Notes |
2017-08-31 10:08:18 | 8/31/17- FAILED | | | | PLEASE INDICATE ON A SURVEY WHERE ON THE GARAGE WALL IS | | THE GENERATOR GOING. | | | | | | PLEASE CONTACT | | NATHAN WIRA- ZONING TECHNICIAN | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING | | DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST. | | WEST PALM BEACH, FL 33402 | | OFFICE HOURS: M-F 8AM - 5PM | | (561)822-1442 | | [email protected] | | |
|
|