Plan Review Stops For Permit 17080930 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-11-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-11-17 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-11-17 |
Time |
14:04 |
Sent To |
|
|
Notes |
2017-11-17 16:19:44 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17110495 | | ADD: 2302 PRESIDENTIAL WAY | | CONT: MEP CONSTRUCTION GROUP | | TEL: 561-557-5840 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 1ST REVIEW | | DATE: FRI. NOV. 17/17 | | | | ACTION: PASSED. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-25 |
Time |
05:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-08-25 |
Time |
05:28 |
Sent To |
|
|
Notes |
2017-08-25 05:59:27 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17080930 | | ADD: 1256 THE POINTE DR. | | CONT: S. O. ENTERPRISES | | TEL: 561-827-6507 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. / AUGUST 25/ 2017 | | ACTION: DENIED | | BUILT: 1987- PRE FAIR HOUSING | | | | 1) CERTIFICATION BY CONTRACTOR. THE CONTRACTOR | | (QUALIFIER) THAT CREATED / DRAWN THE SET OF PLANS WILL | | NEED TO IDENTIFY THEMSELVES AS THE AUTHOR OF THE PLANS. | | PLEASE PRINT YOUR NAME, SIGN YOUR NAME AND LICENSE | | NUMBER FOR THE TRADE YOU ARE LICENSED IN AND PLANS | | DRAWN. 107.3.4.3 CERTIFICATION BY CONTRACTOR. | | | | 2) PLEASE INCLUDE SOFFIT FRAMING PLAN, PROVIDE THE TYPE | | OF FRAMING, WOOD OR METAL, IF METAL PROVIDE THE SIZE | | AND GAUGE OF THE STUD, SPACING AND THE WORST CASE SPAN, | | ALSO INCLUDE THE THICKNESS OF THE DRYWALL. | | 2014 FBC-B TABLE 2506.2 & ASTM 645,& TABLE 2508.1/ ASTM | | C754. | | | | 3) PLEASE PROVIDE IF THERE IS A DIFFERENT UNIT ON THE | | SECOND FLOOR, IF SO PROVIDE A VERTICAL SECTION THROUGH | | THE SOFFIT INCLUDING THE FLOOR FRAMING ASSEMBLY AND THE | | FIRE RATED HORIZONTAL FIRE BARRIER, (2) HOURS IF NOT | | FIRE SPRINKLERED, 1 HOUR IF FIRE SPRINKLERED. FBC-B | | TABLE 707.3.10. | | | | 4) PLEASE ALSO PROVIDE IN THE VERTICAL SOFFIT DETAIL | | THE FINISH FLOOR AND SOFFIT. FBC-B 1208.2. | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-11-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-22 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-22 |
Time |
15:30 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-29 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-29 |
Time |
09:48 |
Sent To |
|
|
Notes |
2017-08-29 09:48:19 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | 471.025; FBC 107.2.1, 107.3.5 | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC | | RE3706.2, RE3902 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-11-13 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-11-13 |
Time |
12:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-08-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-08-25 |
Time |
15:54 |
Sent To |
|
|
Notes |
2017-08-25 16:24:51 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS INSUFFICIENT DETAIL TO MAKE DETERMINATIONS | | REGARDING THE FLORIDA FIRE PREVENTION CODE. | | | | | | 2) IS THERE EXISTING FIRE SPRINKLER PROTECTION? | | | | PROVIDE NOTE. | | | | | | 3) ARE THERE ANY FIRE/SMOKE DETECTION ALARMS IN THE | | AREAS OF CONSTRUCTION. | | | | PLEASE PROVIDE NOTE OF REPLACEMENT OR NEW INSTALLATION | | PER THE FFPC. | | | | | | 4) WHAT TYPE OF NEW FLOOR IS BEING INSTALLED? IS THERE | | ANY NOISE UNDERLAYMENT? PROVIDE PRODUCT SPEC SHEETS FOR | | REQUIRED INTERIOR FLAME AND SMOKE RATINGS? | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-11-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-22 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-08 |
Time |
11:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-09-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-09-13 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-08-18 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-11-16 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-11-16 |
Time |
09:25 |
Sent To |
|
|
Notes |
2017-11-16 09:27:14 | SEPARATE PERMIT REQUIRED FOR MECHANICAL ALTERATIONS. | | CCOLE- 11/16/17 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-08-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-30 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-08-30 |
Time |
15:51 |
Sent To |
|
|
Notes |
2017-08-30 15:56:43 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17080930 | | 8/30/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE A SEPARATE MECHANICAL PLAN THAT | | DETAILS THE MECHANICAL DEMOLTION AND REPLACEMENT OF | | DUCTWORK- SECTION 107.2.1 WPB AMENDMENTS TO THE FBC. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-11-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-11-22 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-11-21 |
Time |
17:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-09-13 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-09-13 |
Time |
10:37 |
Sent To |
|
|
Notes |
2017-09-13 10:40:55 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. IF REPLACING PLUMBING PIPES PLEASE PROVIDE PLAN | | SHOWING LOCATION AND SCOPE OF WORK FOR PLUMBING. PER | | WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|