Plan Review Stops For Permit 17080883 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-01-12 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-01-12 |
Time |
07:29 |
Sent To |
|
|
Notes |
2018-01-12 15:54:02 | ****PROVISOS**** | | ****ISSUED AT APPLICANT'S RISK**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. THE PARKING LOT WAS INSTALLED WITHOUT A PERMIT, | | APPLY AT THIS TIME. AN ACCESSIBLE ROUTE IS REQUIRED AND | | WILL BE REVIEWED UNDER THE PARKING LOT PERMIT. | | | | 2. UNABLE TO LOCATE OCCUPANT LOAD FOR THE BUSINESS | | SPACES, REVISE PLAN TO INCLUDE, FBC B 1004. | | | | 3. NO EXTERIOR LIGHTING SHOWN ON THE ENERGY CALC INPUT | | REPORT; MEANS OF EGRESS ILLUMINATION IS REQUIRED. | | CONFIRM THAT ALL ITEMS REQUIRED TO BE ON THE ENERGY | | CALC ARE INCLUDED. | | | | RESPONSE IS THAT THERE IS NO EXTERIOR ILLUMINATION. | | THIS IS REQUIRED, FBC B 1006.1. REVISE PLAN AND ENERGY | | CALCS ACCORDINGLY, OR SEND EMAIL TO EXPLAIN HOW THIS | | REQUIREMENT WILL BE MET. | | | | 4. A ROOF PRODUCT APPROVAL WAS PROVIDED, ASSEMBLY | | SELECTED WITH A DP LIMITATION OF -52.5. RAS117 | | CALCULATIONS PREPARED BY A DESIGN PROFESSIONAL IS | | REQUIRED PRIOR TO ISSUANCE OF ROOF SUB PERMIT. THIS MAY | | BE SUBMITTED AT TIME OF ROOF PERMIT APPLICATION. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-09-22 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-09-22 |
Time |
15:00 |
Sent To |
|
|
Notes |
2017-09-22 15:06:33 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. FBC A 201.1.1, VERTICAL ACCESSIBILITY IS NOT SHOWN | | FOR THE THREE ELEVATED PLATFORM AREAS. REVISE PLAN TO | | INCLUDE OR REVISE PLAN TO CLARIFY USE OF THE AREAS, | | APPLICALBE EXCEPTION(S). | | | | 2. I WAS UNABLE TO FIND A LIFE SAFETY PLAN. EITHER | | PROVIDE ONE, OR REVISE THE FLOOR PLAN TO INCLUDE | | INFORMATION (OCCUPANT LOAD AND SQUARE FOOT AREA FOR | | EACH SPACE, TRAVEL DISTANCE, COMMON PATH, DEAD ENDS, | | FBC CHAPTER 10). THE OCC LOAD FOR THE ASSEMBLY SPACE | | WAS PROVIDED, BUT IS REQUIRED FOR THE REST OF THE | | BUILDING, FBC 107. | | | | 3. IT APPEARS THAT A PARKING LOT WAS INSTALLED WITHOUT | | A PERMIT, PLEASE APPLY AT THIS TIME OR PROVIDE PERMIT | | NUMBER. | | | | 4. REVISE PLAN TO INCLUDE INFORMATION ABOUT THE | | MERCANTILE AREA - WHAT WILL BE SOLD AND STORED HERE? | | FBC 107. ENERGY CALCS DO NOT APPEAR TO INCLUDE A | | MERCANTILE AREA; PLEASE CORRELATE. IF THIS INFORMATION | | IS NOT AVAILABLE AT THIS TIME, REVISE PLAN TO INDICATE | | THAT FUTURE MERCANTILE TENANT BUILDOUT WILL BE UNDER | | SEPARATE PERMIT. | | | | 5. WHAT IS CURRENTLY THE OCCUPANCY (OR OCCUPANCIES) FOR | | THIS BUILDING? IF THIS IS A CHANGE OF OCCUPANCY, REVISE | | PLAN TO INCLUDE THIS INFORMATION, REVISE PLAN TO SHOW | | COMPLIANCE WITH FBC EB CHAPTER 10. AN IMPACT FEE | | ASSESSMENT MAY BE REQUIRED. | | | | 6. I WAS UNABLE TO LOCATE A DOOR SCHEDULE, PLEASE | | PROVIDE (INCLUDING HARDWARE SCHEDULE), FBC B 1008, FBC | | EC. | | | | 7. NO DOORS ARE SHOWN ON THE ENERGY CALC INPUT REPORT, | | ARE ALL DOORS GLAZED? A HOLLOW METAL DOOR PRODUCT | | APPROVAL WAS SUBMITTED, FBC 107. | | | | 8. NO EXTERIOR LIGHTING SHOWN ON THE ENERGY CALC INPUT | | REPORT; MEANS OF EGRESS ILLUMINATION IS REQUIRED. | | CONFIRM THAT ALL ITEMS REQUIRED TO BE ON THE ENERGY | | CALC ARE INCLUDED. | | | | 9. A ROOF PRODUCT APPROVAL WAS PROVIDED, ASSEMBLY | | SELECTED WITH A DP LIMITATION OF -52.5. RAS117 | | CALCULATIONS PREPARED BY A DESIGN PROFESSIONAL IS | | REQUIRED PRIOR TO ISSUANCE OF ROOF SUB PERMIT. THIS MAY | | BE SUBMITTED AT TIME OF ROOF PERMIT APPLICATION. | | | | 10. ACCESSIBLE ROUTE REQUIRED, FBC A 202.3, 202.4. | | LANDINGS ARE SHOWN AT WHAT APPEARS TO BE THE MAIN | | ENTRANCES. ACCESSIBLE PARKING SHOULD BE ON AN | | ACCESSIBLE ROUTE, ACCESSIBLE ROUTE TO THE ALTERED AREA | | REQUIRED, REVISE TO COMPLY. | | | | 11. FBC B 1026.6, 1022.4&5, ALSO SEE FIRE COMMENT | | REGARDING DOOR RATING. PLEASE ALSO SEE IBC 2012 | | COMMENTARY PAGE 10-165; THIS INDICATES THAT NO OPENINGS | | ARE PERMITTED IN THE STAIR - THIS CAN BE SENT TO YOU | | UPON REQUEST BY EMAIL. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-12-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-12-22 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-12-22 |
Time |
10:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-09-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-20 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-20 |
Time |
10:22 |
Sent To |
|
|
Notes |
2017-09-20 10:21:38 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. NEC 250.94 | | 2. RISER DIAGRAM SHOWS A "FUTURE PANEL C", HOWEVER, | | POWER PLAN SHOWS THIS INSTALLED AND CIRCUITS BEING FED | | FROM THIS PANEL. CLARIFY AND/OR CORRECT. FBC 107.2.1 | | 3. ALL KITCHEN RECEPTACLES REQUIRE GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8 | | 4. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED | | SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | SUBMITTALS WHERE APPLICABLE FOR LOW VOLTAGE SYSTEMS, | | FIRE ALARM, CCTV, PHONE AND DATA, WIRELESS SYSTEMS, | | WALK-IN COOLERS, HOODS, ETC. FBC 105.1, 107.2.1 | | 5. OUTSIDE RECEPTACLE BY A/C EQUIPMENT REQUIRES GFCI | | PROTECTION. PROVIDE CORRECTION. NEC 210.8 | | 6. PROVIDE THE ADDITIONAL LIGHTING CONTROLS STIPULATED | | IN THE FBC ENERGY CODE. PLAN DOES NOT SHOW LIGHTING | | CONTROLLED BY EITHER TIME CLOCK OR OCCUPANCY SENSORS | | REQUIRED. FBC CE 405.2.2, 405.2.2.2 | | 7. PROVIDE GRAPH/CALCULATION OF INTERIOR LIGHTING POWER | | ALLOWANCES PER THE FBC ENERGY CODE IN RELATION TO THE | | CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH | | CODE. FBC CE 405.5 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-12-04 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-12-04 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-12-04 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-08-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-08-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-08-22 |
Time |
16:06 |
Sent To |
|
|
Notes |
2017-08-23 10:39:35 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 2.1 - DOOR # 1 IS INDICATED TO EXIT OUT | | UNDER AN EXIT STAIR AND IS NOT INDICATED AS BEING | | RATED. PER NFPA 101 CHAPTER 7, A 1 HOUR RATED DOOR IS | | REQUIRED. | | | | 7.2.2.6.3 SEPARATION AND PROTECTION OF OUTSIDE STAIRS. | | 7.2.2.6.3.1* OUTSIDE STAIRS SHALL BE SEPARATED FROM THE | | INTERIOR OF THE BUILDING BY CONSTRUCTION WITH THE FIRE | | RESISTANCE RATING REQUIRED FOR ENCLOSED STAIRS WITH | | FIXED OR SELF-CLOSING OPENING PROTECTIVES, EXCEPT AS | | FOLLOWS: | | | | (4) THE FIRE RESISTANCE RATING OF A SEPARATION | | EXTENDING 10 FT (3050 MM) FROM THE STAIRS SHALL NOT BE | | REQUIRED TO EXCEED 1 HOUR WHERE OPENINGS HAVE A MINIMUM | | ?-HOUR FIRE PROTECTION RATING. | | | | PLEASE PROVIDE. | | | | | | 2) SHEET A 4.1 - THE FIRST FLOOR AND ROOF TRUSS SYSTEMS | | ARE INDICATED AS LIGHWEIGHT. | | | | PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR | | STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES | | HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A | | MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND | | 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR. | | THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO | | THE LEFT OF THE MAIN ENTRY DOOR. | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | MARKED WITH THE LETTER "R". | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | SHALL BE MARKED WITH THE LETTER "F". | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | PLEASE PROVIDE. | | | | | | | | 3) SHEET FP 1 - THERE IS A REFERENCE INDICATING | | COMPLAINCE WITH NFPA 13 2007 EDITION. THE CURRENT | | EDITION OF NFPA 13 PER THE FLORIDA FIRE PREVENTION | | CODE, 5TH EDITION IS 2010. | | | | PLEASE CORRECT. | | | | | | | | 4) SHEET FP 1 - THERE IS A CLOSET INDICATED ON THE | | FIRST FLOOR WITH NO DIMENSIONS AND NO SPRINKLER | | PROTECTION. THIS CLOSET IS REQUIRED TO HAVE SPRINKLER | | PROTECTION. | | | | PLEASE PROVIDE. | | | | | | | | 5) SHEET FP 1 - THERE APPEARS TO BE ONE SPRINKLER | | SERVING UNDER THE STAIRS STORAGE SPACE. ANOTHER | | SPRINKLER APPEARS TO BE REQUIRED OR ADD A WALL TO LIMIT | | THE DISTANCE. | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | 6) SHEET A 5.1 - THERE IS REFERENCE TO THE ELEVATOR | | BEING INSTALLED PER MANUFACTURES SPEC. PER NFPA 1, | | CHAPTER 11, BUILDING SERVICES. | | | | 11.3.1 FIRE FIGHTERS? EMERGENCY OPERATIONS. | | 11.3.1.1 ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE | | FIGHTERS? EMERGENCY OPERATIONS REQUIREMENTS OF ASME | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND | | ESCALATORS. [101:9.4.3.1] | | | | PLEAE ENSURE COMPLIANCE AND PROVIDEA AN APPLICABLE | | NOTE. | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-01-12 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-11-30 |
Time |
13:39 |
Sent To |
|
|
Notes |
2018-01-12 17:00:43 | TO CC DESK | | | | | 2017-12-01 13:39:27 | C03 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-10-02 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-02 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-08-17 |
Time |
13:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
N |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-01-12 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-01-12 |
Time |
15:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-09-22 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-09-22 |
Time |
15:00 |
Sent To |
|
|
Notes |
2017-09-22 15:00:31 | SEE BUILDING REVIEW | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-01-18 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-01-18 |
Time |
13:05 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-12-19 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-12-19 |
Time |
14:52 |
Sent To |
|
|
Notes |
2017-12-19 17:01:56 | 2ND REVIEW FBC-2014 MECHANICAL , FBC-14 ENERGY | | CONSERVATION CODE | | PERMIT #17080883 | | 12/19/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-1: THE REQUIRED AUTOMATICALLY CONTROLLED | | SHUTOFF DAMPERS FOR THE O/A DUCTS TO AHU 2 & 3 ARE NOT | | SHOWN. PLEASE NOTE THAT BOTH AIR HANDLERS MUST BE | | EQUIPPED WITH THE DAMPERS- SECTION C403.2.4.4 FBC-14 | | ENERGY CONSERVATION | | | | 2) SHEETS A-1.0, M-1, M-2: SHOW ON THE PLANS THE A-3 | | AREA AND ADJUST THE O/A CALCULATION FOR THAT SPACE IN | | ACCORDANCE WITH TABLE 403.3. | | | | 3) ONE SET OF AC CALCULATIONS IS MISSING FROM THE | | RESUBMITTAL PACKAGE- PLEASE PROVIDE THE MISSING SET. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-09-22 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-09-20 |
Time |
16:09 |
Sent To |
|
|
Notes |
2017-09-22 08:53:04 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17080883 | | 9/22/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-1: INDICATE HOW OUTDOOR AIR IS BEING | | PROVIDED TO AHU-1 & 4- NO O/A DUCTS ARE SHOWN AT THESE | | LOCATIONS. | | | | 2) M-1: PROVIDE AUTOMATICALLY CONTROLLED SHUTOFF | | DAMPERS FOR THE O/A INTAKE DUCTS- SECTION C403.2.4.4 | | FBC-14 ENERGY CONSERVATION. | | | | 3) M-1: PLEASE ENLARGE THE SMOKE DETECTOR SYMBOLS IN | | THE AHU-2 & 3 CLOSET. | | | | 4) M-1 & A2.2: THE AC CLOSET DOORS SHALL BE | | NON-COMBUSTIBLE IN COMPLIANCE WITH SECTION C403.2.7.2 | | FBC-14 ENERGY CONSERVATION AND SECTION 602 FBC-14 | | MECHANICAL. THE PLANS INDICATE WOOD DOORS. | | | | 5) M-1: EXHAUST VENTILATION AT A RATE OF 0.25 CFMS PER | | SQ. FT IS REQUIRED FOR THE LOCKER ROOMS- TABLE 403.3. | | | | 6) M-2: THE 150 MPH WIND SPEED SHOWN IN THE CU MOUNTING | | DETAIL IS NOT CORRECT FOR PUT REGION. PLEASE REFER TO | | SECTION 1609 FBC-BUILDING AND PROVIDE THE CORRECT WIND | | SPEED, AND CURRENT WIND DESIGN CRITERIA FOR | | INSTALLATION OF THE CONDENSERS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-01-12 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-01-12 |
Time |
14:14 |
Sent To |
|
|
Notes |
2018-01-12 14:15:36 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | PROVISO | | | | 1. THE WATER FOUNTAIN SHALL HAVE TWO SPOUTS ONE FOR A | | PERSON IN A WHEEL CHAIR AND ONE FOR A STANDING PERSON. | | PER FBC ACC 211.2 MINIMUM NUMBER. | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | 602.7. | | 602.4 SPOUT HEIGHT. | | SPOUT OUTLETS SHALL BE 36 INCHES (915 MM) MAXIMUM ABOVE | | THE FINISH FLOOR OR GROUND. | | 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. | | SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING | | PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 | | INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND. | | | | SHALL COMPLY BEFORE FINAL INSPECTION. | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-01-10 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-01-10 |
Time |
16:50 |
Sent To |
|
|
Notes |
2018-01-11 09:32:35 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. THE WATER FOUNTAIN SHALL HAVE TWO SPOUTS ONE FOR A | | PERSON IN A WHEEL CHAIR AND ONE FOR A STANDING PERSON. | | PER FBC ACC 211.2 MINIMUM NUMBER. | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | 602.7. | | 602.4 SPOUT HEIGHT. | | SPOUT OUTLETS SHALL BE 36 INCHES (915 MM) MAXIMUM ABOVE | | THE FINISH FLOOR OR GROUND. | | 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. | | SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING | | PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 | | INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-10-02 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-02 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-09-29 |
Time |
13:50 |
Sent To |
|
|
Notes |
2017-10-02 12:58:42 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. PLEASE SHOW CLEAR FLOOR SPACE FOR TOILET , | | LAVATORY'S, SHOWER , WATER FOUNTAIN AND BREAK ROOM | | SINK. PER FBC ACC 602.2 ,604.3.1, 606.2, 608.2.1 | | | | 2. TRANSFER TYPE SHOWER COMPARTMENTS SHALL COMPLY WITH | | FBC ACC 608.2.1 TRANSFER TYPE SHOWER COMPARTMENTS. | | TRANSFER TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES BY | | 36 INCHES CLEAR INSIDE DIMENSIONS MEASURED AT THE | | CENTER POINTS OF OPPOSING SIDES AND SHALL HAVE A 36 | | INCH WIDE MINIMUM ENTRY ON THE FACE OF THE SHOWER | | COMPARTMENT. CLEARANCE OF 36 INCHES WIDE MINIMUM BY 48 | | INCHES LONG MINIMUM MEASURED FROM THE CONTROL WALL | | SHALL BE PROVIDED. | | | | 3. IN TRANSFER TYPE SHOWER COMPARTMENTS, SHOWER SPRAY | | UNIT SHALL BE INSTALLED ON THE SIDE WALL OPPOSITE THE | | SEAT 38 INCHES MINIMUM AND 48 INCHES-MAXIMUM ABOVE THE | | SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL | | 15 INCHES) MAXIMUM FROM THE CENTERLINE OF THE SEAT | | TOWARD THE SHOWER OPENING. PER FBC ACC 608.5.1 | | | | 4. SHOW COMPLIANCE WITH FBC ACC 610.3 IN TRANSFER-TYPE | | SHOWERS, THE SEAT SHALL EXTEND FROM THE BACK WALL TO A | | POINT WITHIN 3 INCHES OF THE COMPARTMENT ENTRY. THE TOP | | OF THE SEAT SHALL BE 17 INCHES MINIMUM AND 19 INCHES | | MAXIMUM ABOVE THE BATHROOM FINISH FLOOR. SEATS SHALL | | COMPLY WITH 610.3.1 OR 610.3.2. | | | | 5. SHT. A2.3 DETAIL #4 CLEAR FLOOR SPACE AT TOILET THE | | DETAIL SHOWING 48" WIDE DO NOT COMPLY PLEASE REMOVE | | FROM PLAN. PER FBC ACC 604.3.1 SIZE. | | CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES | | MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND | | 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR | | WALL. | | | | 6. SHT. A2.3 DETAIL #4 GRAB BARS AT WATER CLOSET (A) | | BACK WALL DOES NOT COMPLY IT SHALL COMPLY WITH FBC ACC | | 604.5.2 REAR WALL. | | THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG MINIMUM | | AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 | | INCHES MINIMUM ON ONE SIDE AND 24 INCHES MINIMUM ON THE | | OTHER SIDE. | | | | 7. GRAB BARS SHALL BE MEASURED TO THE TOP OF THE | | GRIPPING SURFACE TO FINISHED FLOOR. FBC ACC 609.4 | | | | 8. THE CENTERLINE OF THE WATERCLOSET SHALL BE 16"-18" | | OFF SIDE WALL. PER FBC ACC 604.2 | | | | 9. SHT. A2.3 THE LAYOUT OF THE BREAKROOM PLAN DETAIL #5 | | DOES NOT MATCH DETAIL #6 DETAIL #5 DOES NOT SHOW THE | | CABINET ON THE LEFT SIDE OF THE SINK THAT IS SHOWN ON | | DETAIL #6 PLEASE CLARIFY . PER WPB AMEND TO FBC 107.2.1 | | | | 10. SHOW COMPLIANCE WITH FBC ACC 608.3.1 TRANSFER TYPE | | SHOWER COMPARTMENTS. | | IN TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE | | PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO A | | POINT 18 INCHES FROM THE CONTROL WALL. | | | | 11. LAVATORY FAUCETS SHALL COMPLY WITH FBC PL 416.5 | | TEMPERED WATER FOR PUBLIC HAND-WASHING FACILITIES. | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | 1070 OR CSA B125.3. | | | | 12. PLEASE SHOW TRAP PRIMERS ON ALL FLOOR DRAINS AND | | FLOOR SINK ON RISER DIAGRAM. PER WPB AMEND TO FBC | | 107.2.1 | | | | 13. A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH | | WASTE OR SOIL STACK. PER FBC PL 708.3.4 | | | | 14. PROVIDE MANUFACTURE SPEC FOR TANKLESS WATER HEATER | | AND OIL SMART SUMP PUMP. PER WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-09-22 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-09-22 |
Time |
14:59 |
Sent To |
|
|
Notes |
2017-09-22 14:59:45 | A ROOF PRODUCT APPROVAL WAS PROVIDED (14-1030.02 GAF | | MODIFIED BITUMEN), ASSEMBLY SELECTED WITH A DP | | LIMITATION OF -52.5. RAS117 CALCULATIONS PREPARED BY A | | DESIGN PROFESSIONAL IS REQUIRED PRIOR TO ISSUANCE OF | | ROOF SUB PERMIT. THIS MAY BE SUBMITTED AT TIME OF ROOF | | PERMIT APPLICATION. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-01-09 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2018-01-09 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2018-01-09 |
Time |
11:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-09-15 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2017-09-15 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2017-09-15 |
Time |
10:58 |
Sent To |
|
|
Notes |
2017-09-15 11:03:17 | 9/15/17- FAILED. PLEASE PROVIDE THE FOLLOWING | | INFORMATION: | | | | 1. IT APPEARS THAT THE NEW LANDING WILL IMPACT EXISTING | | LANDSCAPE AREA. PLEASE VERIFITY. | | 2. DOES THE NEW STAIRS AND COLUMNS IMPACT THE EXISTING | | LANDSCAPING? | | 3. THE VALUE OF THE RENOVATIONS EXCEEDS 50% OF THE | | VALUE OF THE BUILDING VALUE. WHAT ARE THE PLANS FOR | | ADDITIONAL LANDSCAPING? | | | | ANGELLA VANN | | 561-822-1441 | | [email protected] |
|
|