Plan Review Details - Permit 17080677
Plan Review Stops For Permit 17080677 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-13 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-10 |
Time |
07:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-02-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-02-16 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-02-15 |
Time |
09:42 |
Sent To |
|
|
Notes |
2018-02-16 07:58:53 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. | | 2. PROVIDE PRODUCT APPROVALS FOR NEW EXTERIOR DOORS. | | 3. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | BBQ GRILL. | | 4. NEW COMMENT - NOA 13-0419.04 FOR ASPHALT SHINGLES | | HAS EXPIRED. PROVIDE CURRENT NOA OR FL PRODUCT APPROVAL | | FOR NEW ROOFING PRODUCTS. | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-09-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-14 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-14 |
Time |
07:27 |
Sent To |
M |
|
Notes |
2017-09-14 15:25:31 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE SOILS REPORT. | | 2. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED. | | 3. PROVIDE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR | | BBQ GRILL. | | 4. PROVIDE PRODUCT APPROVALS FOR NEW EXTERIOR DOORS. | | | | R401.4 SOIL TESTS. | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | APPROVED METHOD. | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-10-12 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-12 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-12 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-02-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-02-09 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-02-09 |
Time |
15:07 |
Sent To |
|
|
Notes |
2018-02-09 15:06:55 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. SEE NEW | | COMMENT THAT FOLLOWS THE ORIGINAL COMMENTS. | | | | 1. CORRECTED. | | 2. CORRECTED. | | 3. CORRECTED. | | 4. CORRECTED. | | 5. PROVIDE SPEC SHEET FOR EXISTING METER CAN SHOWING | | DOUBLE LUG COMPATIBLE. DESCRIBE METHOD OF DOUBLE LUG | | TAP. FBC 107.2.1, NEC 110.3 (PLAN SHOWS A TAP FROM THE | | 200 AMP DISCONNECT TO BE INSTALLED. WHAT IS THE METHOD | | OF THIS TAP? MOST 200 AMP DISCONNECTS HAVE A LUG RATED | | FOR A SINGLE WIRE, NOT FOR TWO AS SHOWN IN RISER. | | PROVIDE CLARIFICATION AND/OR CORRECT.) | | 6. CORRECTED. | | 7. CORRECTED. | | 8. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER FOR PANEL A AT THE NEW BUILDING. NEC | | 225.31, 225.32 (THE MOUNTING LOCATION OF THE DISCONNECT | | THAT WAS ADDED FOR THIS IS NOT SHOWN ON POWER PLAN. | | SHOW LOCATION OF DISCONNECT SO RISER AND POWER PLAN | | MATCH. FBC 107.2.1) | | 9. A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | RE3607.3 (NOTE ON PLAN STATES THIS IS NOT REQUIRED PER | | FIGURE 250.87, WHICH DOES NOT EXIST. THIS IS REQUIRED, | | PROVIDE AS PREVIOUSLY REQUESTED. SEE EXHIBIT 250.19 IN | | THE NEC HANDBOOK FOR FURTHER CLARIFICATION.) | | 10. CORRECTED. | | 11. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | FBC RE3903.3 (A SWITCH SHOULD BE LOCATED AT EACH GRADE | | LEVEL ACCESS, ONE IS MISSING.) | | 12. CORRECTED. | | | | NEW COMMENT: | | | | 13. PLEASE BE ADVISED THAT SOME COMMENTS HAVE NOT BEEN | | ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD REVIEW, IF | | IT IS NECESSARY TO REJECT THE SUBMITTED PLAN A THIRD | | TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW IS | | REQUIRED. FLORIDA STATUTES STATE: ?WITH RESPECT TO | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)? | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-29 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-29 |
Time |
15:24 |
Sent To |
|
|
Notes |
2017-08-29 15:24:11 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. NOTE # 1 STATES THAT RECEPTACLES SHALL BE TAMPER | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE4002.14 | | 2. NOTE # 11 STATES THAT LIGHTING IN CLOTHES CLOSETS | | SHALL COMPLY WITH NEC 4/10.8/D/1, WHICH DOESN?T EXIST. | | PROVIDE CORRECTION. NEC 410.16; FBC RE4003.12 | | 3. SEVERAL ELECTRICAL NOTES REFER TO EXISTING | | INSTALLATION, BUT THE PERMIT APPLICATION STATES THIS IS | | A NEW BUILDING. REMOVE ANY NOTES NOT PERTAINING TO THIS | | JOB. FBC 107.2.1 | | 4. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. NEC 250.94; FBC RE3609.3 | | 5. PROVIDE SPEC SHEET FOR EXISTING METER CAN SHOWING | | DOUBLE LUG COMPATIBLE. DESCRIBE METHOD OF DOUBLE LUG | | TAP. FBC 107.2.1, NEC 110.3 | | 6. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE3602.3 | | 7. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, LOCATION OF MAIN DISCONNECTS AND | | LABELING FOR THOSE DISCONNECTS, UNDERGROUND OR OVERHEAD | | SERVICE, WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO | | INTERIOR PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 FBC RE3706.1, RE3608.1, | | RE3609.3; FBC 107.2.1 | | 8. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER FOR PANEL A AT THE NEW BUILDING. NEC | | 225.31, 225.32 | | 9. A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | RE3607.3 | | 10. ADDRESS PANEL A LOCATION. OVERCURRENT PROTECTION | | DEVICES ARE NOT PERMITTED IN THE VICINITY OF EASILY | | IGNITABLE MATERIAL, SUCH AS IN CLOTHES CLOSETS. PROVIDE | | CLARIFICATION AND/OR CORRECTION. NEC 240.24(D); FBC | | RE3705.7 | | 11. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | FBC RE3903.3 | | 12. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | FBC CE R404.1 | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2018-10-31 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-31 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-31 |
Time |
12:48 |
Sent To |
|
|
Notes |
2018-10-31 16:01:08 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2012 | | 5TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2014 5TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2014 5TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2014 5TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2014 5TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 3RD REVIEW: | | GAS PIPING COMMENTS: DENIED | | | | 1. RE: WPB FBC 107.2.1; MANUFACTURER?S SPECIFICATION | | SHEETS REQUIRED SUBMITTALS | | A) NG LINE REGULATOR (MP) | | ? PROVIDE ONE SPEC SHEET TO ACCOMPANY EACH APPLIANCE | | INCLUSIVE OF EXISTING POOL HEATER, NOTING INDOOR OR | | OUTDOOR APPLICATION AND SPECIFY CORRECT VENT LIMITING | | DEVICE OR VENT PROTECTOR AS REQUIRED BY APPLICATION. | | B) TANKLESS WATER HEATER | | ? RINNAI RL75E IS NOT FOR INDOOR INSTALLATION | | 1) SUBMIT A UNIT FOR INDOOR USE | | 2) PROVIDE DETAIL AND MANUFACTURER?S RECOMMENDED VENT | | TERMINATION KIT SPEC | | 3) IDENTIFY RUSKIN LOUVER AS 12 X 18 COMBUSTION AIR | | VENT | | 4) PROVIDE SPEC SHEET FOR LINE REGULATOR AS REQUIRED BY | | APPLICATION | | C) BBQ GRILL | | ? SALES BROCHURE IS NOT ADEQUATE | | 1) PROVIDE MANUFACTURER?S SPEC SHEET FOR UNIT. | | 2) PROVIDE SPEC SHEET FOR LINE REGULATOR AS REQUIRED BY | | APPLICATION | | D) EXISTING EQUIPMENT | | ? POOL HEATER | | 1) PROVIDE MANUFACTURER?S SPEC SHEET FOR UNIT. | | 2) PROVIDE SPEC SHEET FOR LINE REGULATOR AS REQUIRED BY | | APPLICATION | | 2. REVISE THE GAS PIPING RISER DIAGRAM THAT SHOWS THE | | TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH | | APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH | | APPLIANCE INCLUSIVE OF THE EXISTING POOL HEATER, THE | | RUN FROM THE NEW APPLIANCES BACK TO THE INTERSECTION | | WITH THE BRANCH TO THE EXISTING POOL HEATER, THE RUN | | FROM THAT INTERSECTION TO THE UPGRADED REGULATOR AND | | METER AND THE DISTANCE OF THE LONGEST LENGTH OF PIPING | | FROM THE POINT OF DELIVERY TO THE MOST REMOTE OUTLET | | INCLUSIVE OF THE EXISTING POOL HEATER AND THE LOAD OF | | THE SECTION. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | ADDITIONAL NOTES; DOES NOT APPLY TO PERMIT APPLICATION | | | | 1. CITY RECORDS SHOW .5LB GAS ON EXISTING SYSTEM. | | PROVIDE AFFIDAVIT OF GAS PIPING TEST TO INCLUDE OF | | EXISTING SYSTEM FOR FINAL INSPECTION IN ACCORDANCE WITH | | FBC FG 406 TO INSURE IT IS 2PSI CAPABLE. | | 2. THE INSTALLATION MANUALS FOR ALL GAS APPLIANCES / | | EQUIPMENT SHALL BE ONSITE AT THE TIME OF INSPECTION. | | FGC SEC.305.1, FBC-RES. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2018-02-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-15 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-15 |
Time |
08:15 |
Sent To |
|
|
Notes |
2018-02-15 09:08:32 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | GAS COMMENTS: PREVIOUS COMMENTS ARE NOT COMPLIED WITH | | IN ORDER TO EXPEDITE THE APPROVAL OF THIS PLAN I | | SUGGEST A MEETING BE SCHEDULED TO GO OVER COMMENTS | | BEFORE THE NEXT RESUBMITTAL. | | | | CITY RECORDS SHOW MUILT PERMITS ISSUED FOR .5LB GAS ON | | MAIN HOME. | | | | PARTIALLY COMPLIED 1) LIST THE BTU LOAD OF EACH | | APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM. REFER | | TO THE 2014 FBC-FUEL GAS SECS.401.8 THRU 402.6.1 AND | | TABLES 402.4 (1) THRU 402.4 (37) OR 2014 FBC-RES. SEC. | | G2413. SHOW BTU LOAD ON THE GAS RISER. | | | | 2ND REQUEST 2) SUBMIT MANUFACTURER?S SPECIFICATION | | SHEETS / INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | FBC-2014 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2014 | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 2ND REQUEST 5) THE PLANS INDICATE AN EXISTING GAS | | METER. THE BTU LOAD OF THE EXISTING GAS SYSTEM MUST BE | | ADDED INTO THE TOTAL BTU LOAD ON THE SYSTEM TO ENSURE | | THE EXISTING SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, | | THE EXISTING SYSTEM MUST BE REDONE TO ENSURE A SAFE | | OPERATING SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM | | THAT SHOWS THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD | | OF EACH APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO | | EACH APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH | | OF PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE | | OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE | | EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE | | SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE | | REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES. | | FGC SECS. 401.4, 401.8, 402.1, 402.2, 402.3 OR FBCR | | SECS.G2412.4, G2412.8, G2413.1, G2413.2, G2413.3. | | THE GAS OR PLUMBING CONTRACTOR CANNOT TIE INTO THE GAS | | UTILITIES LINE ONLY THE GAS UTILITIES COMPANY CAN DO | | THAT WHICH IS FLORIDA PUBLIC UTILITIES. IF YOU HAVE FPU | | INSTALL A NEW METER WITH A 2PSI REGULATOR SHOW IT ON | | THE RISER ALONG WITH THE DISTANCE FROM THE METER TO THE | | FURTHEST APPLIANCE SHOWN ON THE RISER. | | REMOVE NOTE #4 FROM SCOPE OF WORK. | | | | 2ND REQUEST 6) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR | | THE PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | INSTALLATION. 2014 FGC SEC.410.1. | | | | 2ND REQUEST 7) SHOW THE DISTANCE FROM THE 2 PSI | | REGULATOR TO THE APPLIANCE. COMPLY WITH 2014 FBC-FUEL | | GAS TABLE 402.4 (28) FOR THE PROPER PIPE SIZE AND BTU | | LOAD. | | | | NEW COMMENTS: | | | | 1. SHOW ON THE GAS RISER THE TRANSITION FROM PE PIPE TO | | TYPE OF PIPING BEFORE INTERRING BUILDING FOR THE | | TANKLESS HEATER. PE PIPING CANNOT RUN IN OR UNDER THE | | BUILDING. PER WPB AMEND TO FBC 107.2.1 | | | | 2. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENT FOR WATER HEATER PER | | FBC-2014 FUEL GAS CODE SEC. 502 THRU 505. | | | | 3. THE 10 X10 OPENING FOR COMBUSTION AIR SHALL COMPLY | | WITH FBC MECH. 401.5 PROVIDE MANUFACTURE SPECS AND | | PRODUCT APPROVAL. PER WPB AMEND TO FBC 107.2.1 | | | | 4. SHOW TYPE OF PIPE AND PRESSURE ON THE RISER. PER WPB | | AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-08-29 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-08-29 |
Time |
07:15 |
Sent To |
|
|
Notes |
2017-08-29 07:22:10 | 1ST REVIEW DENIED | | | | CITY RECORDS SHOW MUILT PERMITS ISSUED FOR .5LB GAS ON | | MAIN HOME. | | | | 1) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | BTU LOAD ON THE SYSTEM. REFER TO THE 2014 FBC-FUEL GAS | | SECS.401.8 THRU 402.6.1 AND TABLES 402.4 (1) THRU 402.4 | | (37) OR 2014 FBC-RES. SEC. G2413 | | | | 2) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | FBC-2014 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2014 | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | 3 )SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS | | APPLIANCES. WHERE COMBUSTION AIR IS PROVIDED BY THE | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | ADDITION TO THE REQUIRED VENTILATION AIR. FGC | | SEC.304.9.3 OR FBCR G2407.9.3. | | | | 4) SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | AHEAD OF EACH MP REGULATOR. FBC-FUEL GAS SEC.409.4, | | FBC-RESIDENTIAL SEC. G 2420.4 | | | | 5) THE PLANS INDICATE AN EXISTING GAS METER. THE BTU | | LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE | | TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING | | SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE EXISTING | | SYSTEM MUST BE REDONE TO ENSURE A SAFE OPERATING | | SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM THAT SHOWS | | THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH | | APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH | | APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH OF | | PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE | | OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE | | EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE | | SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE | | REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES. | | FGC SECS. 401.4, 401.8, 402.1, 402.2, 402.3 OR FBCR | | SECS.G2412.4, G2412.8, G2413.1, G2413.2, G2413.3. | | | | 6) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | INSTALLATION. 2014 FGC SEC.410.1. | | | | 7) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE | | APPLIANCE. COMPLY WITH 2014 FBC-FUEL GAS TABLE 402.4 | | (28) FOR THE PROPER PIPE SIZE AND BTU LOAD. | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS | | | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2018-01-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-01-30 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-01-30 |
Time |
11:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-08-18 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-08-18 |
Time |
10:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-13 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-05 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-02-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-02-16 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-23 |
Time |
11:25 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-09-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-09-15 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-08-14 |
Time |
12:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-09-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-14 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-14 |
Time |
07:28 |
Sent To |
|
|
Notes |
2017-09-14 15:19:48 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-01-31 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-01-31 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-01-31 |
Time |
10:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-09-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-09-15 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-09-15 |
Time |
10:21 |
Sent To |
|
|
Notes |
2017-09-15 10:24:36 | PLAN DENIED | | PROVIDE CAN SIZE ON PLANS. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-10-31 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-31 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-31 |
Time |
16:19 |
Sent To |
|
|
Notes |
2018-10-31 16:21:41 | APPROVED | | PROVISO | | | | GAS TANKLESS WATER HEATER SPEC AND DETAIL TO BE | | SUBMITTED AND APPROVED UNDER GAS PERMIT. | | | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-02-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-15 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-14 |
Time |
11:07 |
Sent To |
|
|
Notes |
2018-02-15 09:09:35 | SHALL COMPLY WITH GAS COMMENTS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-08-29 |
Time |
07:13 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-08-28 |
Time |
15:24 |
Sent To |
|
|
Notes |
2017-08-29 07:15:26 | PROVIDE OUTSIDE SHOWER DETAIL SHOWING HOW YOU PLAN ON | | STOPPING STORM WATER FROM ENTERING SEWER SYSTEM FPC | | 1101.3 | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2017-09-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-14 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-14 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
X |
PERMIT EXTENSION |
Rev No |
1 |
Status |
P |
Date |
2019-06-11 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2019-06-11 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2019-06-11 |
Time |
10:31 |
Sent To |
|
|
Notes |
2019-06-11 10:32:26 | APPLICATION HAS BEEN EXTENDED 90 DAYS PER ROBERT BROWN |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-01-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-01-30 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-01-30 |
Time |
11:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-08-18 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-08-18 |
Time |
10:22 |
Sent To |
|
|
Notes |
|
|
|