Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-10-25 Cont ID  
Sent By aclange Date 2017-10-25 Time 14:32 Rev Time 0.00
Received By aclange Date 2017-10-25 Time 14:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-08-14 Cont ID  
Sent By wjolin Date 2017-08-16 Time 12:42 Rev Time 0.00
Received By cthroop Date 2017-08-14 Time 10:16 Sent To FIRE
Notes
2017-08-14 10:22:21BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DETAIL SPECIFIES THE USE OF TAPCONS TO SECURE TRACK
 TO WALL.
 2. PLAN SPECIFIES THE USE OF WEDGE ANCHORS.
 3. IDENTIFY THE WALL TYPE AWNING WILL BE ATTACHED TO.
 4. PROVIDE FASTENER SCHEDULE BASED ON WALL TYPE AND
 WIND LOADS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-10-25 Cont ID  
Sent By wjolin Date 2017-10-25 Time 09:51 Rev Time 0.00
Received By wjolin Date 2017-10-25 Time 09:43 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-08-16 Cont ID  
Sent By wjolin Date 2017-08-16 Time 12:41 Rev Time 0.00
Received By wjolin Date 2017-08-16 Time 12:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-25 Cont ID  
Sent By aclange Date 2017-10-25 Time 14:32 Rev Time 0.00
Received By aclange Date 2017-10-17 Time 14:54 Sent To  
Notes
2017-10-18 14:54:54RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-08-16 Cont ID  
Sent By cthroop Date 2017-08-16 Time 12:42 Rev Time 0.00
Received By wjolin Date 2017-08-08 Time 10:05 Sent To  
Notes
2017-08-09 10:05:20ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2017-10-23 Cont ID  
Sent By eschneid Date 2017-10-23 Time 16:42 Rev Time 0.25
Received By eschneid Date 2017-10-23 Time 16:42 Sent To FIRE
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-08-11 Cont ID  
Sent By eschneid Date 2017-08-11 Time 12:59 Rev Time 0.25
Received By eschneid Date 2017-08-11 Time 12:59 Sent To B
Notes
2017-08-11 13:11:39FAILED
  
 PROVIDE WRITTEN RESPONSE TO COMMENTS.
  
 1) PROVIDE TWO COPIES OF A CURRENT SITE PLAN SHOWING
 THE PROPOSED AWNING LOCATION. THE MORSE FACILITY HAS
 GONE THROUGH MANY RENOVATIONS SINCE THE SITE PLAN
 SUBMITTED WITH THE APPLICATION WAS "CURRENT".
  
 2) IF THE PROPOSED AWNING IS NOT SHOWN ON THE CURRENTLY
 APPROVED PLANS, THEN A MINOR PLANNED DEVELOPMENT
 AMENDMENT TO THE SITE PLAN IS REQUIRED PRIOR TO ZONING
 APPROVAL.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
 [email protected]
2017-08-10 14:23:19ROUTED TO ERIC SCHNEIDER