Plan Review Stops For Permit 17080211 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-07-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-07 |
Time |
18:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-07 |
Time |
18:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-06-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-09 |
Time |
19:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-09 |
Time |
19:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-08-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-08-14 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-08-14 |
Time |
15:53 |
Sent To |
|
|
Notes |
2017-08-14 16:17:19 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. PLAN LACKS A SIGNIFICANT AMOUNT OF INFORMATION SUCH | | AS OCCUPANCY CLASSIFICATION, LIFE SAFETY PLAN (TRAVEL | | DISTANCES, EXITS, COMMON PATH OF TRAVEL, ETC.), | | OCCUPANT LOAD, COMPLIANCE WITH FBC ACCESSIBILITY. AS A | | BUILDING PLAN WAS NOT PROVIDED, A COMPLETE REVIEW | | CANNOT BE DONE AT THIS TIME. SOME INFORMATION ON THE | | PLAN IS NOT CLEAR. | | | | FOR INSTANCE, GENERAL NOTES STATES THAT OCCUPANCY TYPE | | IS R1, BUT APPLICATION STATES A HAIR SALON IS PROPOSED. | | IS THIS A CHANGE OF OCCUPANCY? | | | | SOME NOTES ARE NOT CLEAR AS TO MEANING; "ALL CONTRACTOR | | TREAD, SHALL PROVIDE THEIR INFORMATION AND SIGN THEIR | | DRAWING." | | | | FBC 107, PROVIDE AN ARCHITECTURAL QUALITY PLAN PREPARED | | BY A LICENSED DESIGN PROFESSIONAL, FS 471, 481. AN | | ELECTRICAL CONTRACTOR DESIGNED THE ELECTRICAL PORTION, | | A PLUMBING CONTRACTOR (PARTIALLY) DESIGNED THE PLUMBING | | PORTION (BUT NO ACCESSIBILITY INFORMATION PROVIDED). | | SOMETHING WHICH IS LABELED "WALL DETAIL DNS" IS ON THE | | PLAN BUT NOT CLEAR WHETHER THE PLUMBING CONTRACTOR OR | | THE ELECTRICAL CONTRACTOR IS DESIGNING THIS WORK. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-06-15 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-06-15 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-06-15 |
Time |
10:24 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-08-14 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-14 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-14 |
Time |
11:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-05-31 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-05-31 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-05-31 |
Time |
11:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2017-08-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-08-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-08-11 |
Time |
15:05 |
Sent To |
|
|
Notes |
2017-08-14 10:02:40 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | | | 1) THERE APPEARS TO BE NEW AREAS THAT MAY NOT BE | | PROTECTED BY THE EXISTING FIRE SPRINKLERS. PLEASE HAVE | | THE PROPOSED WORK REVIEWED BY A FIRE SPRINKLER | | CONTRACTOR FRO PROPER CODE PROTECTION COVERAGE. | | | | THE AREA SHALL ALSO BE REVIEWED BY A FIRE INSPECTOR ON | | ANY FIRE INSPECTION. NOT HAVING PROPER FIRE SPRINKLER | | PROTECTION SHALL RESULT IN A FAILED FIRE FINAL. | | | | ANY WORK ON THE FIRE SPRINKLER SYSTEM SHALL BE DONE | | UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | CONTRACTORS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-14 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-10 |
Time |
10:53 |
Sent To |
|
|
Notes |
2018-07-12 10:53:48 | IMPACT FEES ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-07-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-07-10 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-06-22 |
Time |
15:11 |
Sent To |
|
|
Notes |
2018-07-07 18:45:19 | TO GJ DESK | | | | | 2018-06-25 15:11:37 | B23 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-06-15 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-05-25 |
Time |
10:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-08-21 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-08-21 |
Time |
19:05 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-08-03 |
Time |
15:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2018-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-14 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-14 |
Time |
09:28 |
Sent To |
|
|
Notes |
2018-07-14 09:28:38 | $0 DUE | | NO MU NUMBER ON PLAN, BUT PLAN IS STAMPED | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2018-07-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-07 |
Time |
18:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-07 |
Time |
18:43 |
Sent To |
|
|
Notes |
2018-07-07 18:43:30 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | THAT FEES DUE, IF APPLICABLE, PROVIDED. | | | | AFTER ALL OTHER REVIEWS HAVE PASSED, CHECK OUT ONE SET | | OF PLANS TO TAKE TO THE COUNTY. | | | | 561-233-5025 FOR MORE INFORMATION | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-08-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-08-14 |
Time |
06:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-08-14 |
Time |
06:24 |
Sent To |
|
|
Notes |
2017-08-28 06:25:18 | SEE BUILDING REVIEW | | IMPACT FEE REVIEW BY PALM BEACH COUNTY MAY BE REQUIRED | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2018-07-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-07-02 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-06-29 |
Time |
17:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-06-05 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-06-05 |
Time |
16:51 |
Sent To |
|
|
Notes |
2018-06-05 17:36:07 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #17080211 | | 6/5/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | NEW VRF SYSTEM- SECTION C403.2.1 FBC EC. | | | | 2) SHEET M-1: REFER TO SECTION 501.4 FBC M AND INDICATE | | HOW COMPLIANCE WILL BE MET FOR PRESSURE EQUALIZATION. | | WILL THE EXHAUST BE LINKED TO THE OUTDOOR AIR SYSTEM? | | THE PLANS APPEAR TO INDICATE A MANUAL SWITCH FOR THE | | FAN. PLEASE PROVIDE AN AIR BALANCE CALCULATION. | | | | 3) M-1: SHEET PROVIDE AN ACCESS PANEL FOR THE INLINE | | FAN- SECTION 306.1 FBC M. | | | | 4) M-1: EXHAUST VENTILATION IS REQUIRED FOR THE SHOWER | | ROOM- TABLE 403.3.1 | | | | 5) M-1: PROVIDE WINDLOAD ENGINEERING FOR INSTALLATION | | OF THE CONDENSER AND CONDENSER STAND- SECTION 301.15 | | FBC M. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-08-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-16 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-08-16 |
Time |
07:40 |
Sent To |
|
|
Notes |
2017-08-16 10:28:07 | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | PERMIT #17080211 | | 8/16/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE HAIR SALON REQUIRES EXHAUST VENTILATION AT A | | RATE OF 0.60 CFMS PER SQ. FT., AND THE RECIRCULATION OF | | ANY AIR FROM THE SPACE IS PROHIBITED- SEE TABLE 403.3 | | AND FOOTNOTE B. PLEASE PROVIDE A SYSTEM THAT MEETS | | COMPLIANCE. | | | | 2) REFER TO SECTIONS 809.1 & 809.2 FBC-14 EXISTING | | BUILDING CODE AND PROVIDE MINIMUM VENTILATION | | CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE 403.3 | | FBC-14 MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES | | THE REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR. | | | | 3) PROVIDE A SCOPE OF WORK FOR MECHANICAL ON THE PLAN | | WITH CORRESPONDING DRAWINGS AND DETAILS. SHOW ALL | | ALTERATIONS TO THE EXISTING HVAC SYSTEMS. | | | | 4) THE BUILDING PLANS EXAMINER IS REQUIRING CODE | | COMPLIANT PLANS DONE BY A LICENSED ARCHITECT WHICH WILL | | CLARIFY WHETHER THE PROPOSED PROJECT IS A CHANGE OF | | OCCUPANCY OR CHANGE OF USE FROM THE PREVIOUS OCCUPANCY. | | BASED ON THOSE COMMENTS, THE MECHANICAL REVIEW IS | | STOPPED AT THIS TIME UNTIL NEW PLANS ARE RESUBMITTED | | FOR REVIEW. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-07-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-07-10 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-07-10 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-06-14 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-06-14 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-06-14 |
Time |
12:46 |
Sent To |
|
|
Notes |
2018-06-14 18:13:49 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. AT LEAST ONE OF THE WORK SINKS SHALL COMPLY WITH FBC | | ACC 212.3 , 606 | | | | 2. WHAT SINK IS THE WATER HEATER DRAIN PAN DISCHARGING | | INTO PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 3. PROVIDE 2 COPIES OF THE MANUFACTURE SPECIFICATIONS | | OF THE WET TABLE IN THE VICHY SHOWER AND THE HAIR | | WASHING CHAIR SINK ONLY ONE WAS PROVIDED ALSO THE | | SHOWER VALVE. PER WPB AMEND TO FBC 107.2.1 | | | | 4. THE HAIR WASH SINK SHALL BE EQUIPPED WITH A VACUUM | | BREAKER. PER FBC PL 608.2 | | | | 5. ALL VALVES SHALL COMPLY WITH NSF 372 LEAD FREE . PER | | FBC PL 605.2.1 | | | | 6. SHT. P-3 DETAIL I THE SHOWER LINER SHALL BE PITCHED | | TO TH DRAIN. PER FBC PL 417.5.2 | | | | 7. THE LAVATORY IN THE BATHROOM SHALL COMPLY WITH | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | 1070 OR CSA B125.3.PER FBC PL 416.5 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-08-21 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-08-21 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-08-18 |
Time |
16:26 |
Sent To |
|
|
Notes |
2017-08-21 13:05:42 | 1) CHANGE OF OCCUPANCY REQUIRES PER FBC 1012.8 AND | | 1006.1 RESTROOM TO COMPLY FULLY WITH ALL OF CHAPTER 6 | | OF THE FBC 2014 ACCESSIBILITY | | 2) PLAN LACKS SIGNIFICANT AMOUNT OF INFORMATION TO | | COMPLETE A THOUROUGH REVIEW AT THIS TIME. PROVIDE LOAD | | AND BATHROOM DETAIL | | | | TIM HUNT | | PLUMBING INSPECTOR / PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6696 | | [email protected] | | |
|
|