Plan Review Details - Permit 17080096
Plan Review Stops For Permit 17080096 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-08-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-24 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-24 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-08-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-14 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-10 |
Time |
11:17 |
Sent To |
|
|
Notes |
2017-08-14 09:29:42 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE EXTERIOR DOOR PRODUCT APPROVAL THAT WAS | | SUBMITTED (FL10537-R2) IS NOT THE ONE THAT IS SPECIFIED | | ON THE PLANS (FL15227-R2). PLEASE CLARIFY. FBC | | 107.3.4.1 | | | | 2) THE REQUIRED COMPONENT AND CLADDING PRESSURES FOR | | THE NEW EXTERIOR DOORS ARE NOT SPECIFIED ON THE PLANS. | | FBC-R301.2.1 | | | | 3) FBC-R310.1 EMERGENCY ESCAPE AND RESCUE OPENINGS ARE | | REQUIRED FROM ROOMS USED FOR SLEEPING. THIS IS AN | | EXISTING SINGLE FAMILY DWELLING AND FBC EXISTING | | BUILDING SECTION 704.1 HAS AN EXECPTION THAT ALLOWS A | | MAXIMUM 5 PERCENT REDUCTION IN THE CLEAR OPENING | | DIMENSIONS OF REPLACEMENT WINDOWS AS LONG AS THE | | PORTION OF THE BUILDING IS NOT ALTERED SUCH THAT THE | | BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION | | PER SECTION 701.2. SHOW ON THE PLANS HOW THE NEW | | WINDOWS WILL COMPLY WITH SECTION 701.2 OR HOW THE | | OPENINGS WILL BE ALTERED TO COMPLY WITH FBC-R310.1. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-08-23 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-23 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-23 |
Time |
16:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-08-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-07 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-07 |
Time |
14:05 |
Sent To |
|
|
Notes |
2017-08-07 14:05:07 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED AND SEALED | | BY A DESIGN PROFESSIONAL OR THE ELECTRICAL CONTRACTOR | | QUALIFIER. FS 471.003(2)(H); 471.025; FBC 107.2.1 | | 2. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | 215.5; FBC 107.2.1 | | 3. PROVIDE ACCURATE LOAD CALCULATION FOR RESIDENCE. NEC | | 220; FBC RE3602.3 | | 4. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC | | RE3706.2, RE3902 | | 5. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-08-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-24 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-22 |
Time |
15:48 |
Sent To |
|
|
Notes |
2017-08-23 15:48:36 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-08-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-14 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-02 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-08-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-24 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-24 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-08-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-10 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-10 |
Time |
13:23 |
Sent To |
|
|
Notes |
2017-08-10 15:26:12 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY MECHANICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC - 107.3.5.3 PROVIDE TWO SETS OF A MECHANICAL | | PLAN TO SHOW EQUIPMENT AND LOCATION AND DUCT SYSTEMS | | PER FBC-R M16 & BATH EXHAUST PER FBC-R M15. SHOW ALL OF | | THE DUCT WORK ON THE PLANS INCLUDING THETRUNK LINE. | | SHOW THE RETURN AIR TO THE AIRHANDLER ON THE PLANS. IN | | ORDER TO PROVIDE CLARITY THE MECHANICAL PLANS SHOW BE | | ON A SEPARATE FLOOR PLAN. | | | | 2) FBC ENERGY CONSERVATION R403.2.1 REQUIRES SUPPLY | | DUCTS IN ATTICS TO HAVE R-8 INSULATION. PLEASE CORRECT | | THE PLANS. | | | | 3) ENERGY COMPLIANCE FORM R405-2014 IS REQUIRED TO HAVE | | THE PREPARER'S NAME AND THE SIGNATURE OF THE | | OWNER/AGENT ON THE FORM. FBC ENERGY CONSERVATION R103 | | | | 4) THE FORM STATES THAT THIS IS WORST CASE. WORST CASE | | IS USED WHEN THE SAME MODEL HOME WILL BE BUILT ON | | DIFFERENT LOTS WITH DIFFERENT ORIENTATIONS. THIS IS NOT | | THE CASE WITH THIS PROJECT. THEREFORE, THIS IS NOT | | WORST CASE AND IS REQUIRED TO SHOW THE ACTUAL | | ORIENTATION OF THE HOME. FBC ENERGY CONSERVATION | | R405.4.2 | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2017-08-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-10 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-10 |
Time |
11:27 |
Sent To |
|
|
Notes |
2017-08-10 11:28:59 | NO PLUMBING WORK IS INDICATED ON THE PLANS. A SEPARATE | | PERMIT, APPLICATION AND REVIEW IS REQUIRED. |
|
|
|