Plan Review Details - Permit 17080085
Plan Review Stops For Permit 17080085
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-09-14 Cont ID  
Sent By cthroop Date 2017-09-14 Time 06:54 Rev Time 0.00
Received By cthroop Date 2017-09-13 Time 13:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-08-15 Cont ID  
Sent By cthroop Date 2017-08-15 Time 08:38 Rev Time 0.00
Received By cthroop Date 2017-08-14 Time 16:24 Sent To P
Notes
2017-08-07 15:00:01THIS NOTE CREATED BY ACCIDENT, SEE ELECTRICAL TAB.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-08-29 Cont ID  
Sent By jpearson Date 2017-08-29 Time 10:27 Rev Time 0.00
Received By jpearson Date 2017-08-29 Time 10:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-08-07 Cont ID  
Sent By jpearson Date 2017-08-07 Time 15:02 Rev Time 0.00
Received By jpearson Date 2017-08-07 Time 15:02 Sent To  
Notes
2017-08-07 15:02:08CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED AND SEALED
 BY A DESIGN PROFESSIONAL OR THE ELECTRICAL CONTRACTOR
 QUALIFIER. FS 471.003(2)(H); 471.025; FBC 107.2.1
 2. PROVIDE MORE DETAIL FOR PANEL SCHEDULE, INDICATING
 ANY NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE
 FOR THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE
 APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12,
 215.5, 408.4; FBC RE3706.2, RE3902
 3. WATER HEATER BREAKER SHOULD BE RATED AT 125% OF FULL
 LOAD CURRENT. 30 AMP BREAKER STATED IS TOO LARGE.
 PROVIDE CORRECTION. NEC 422.13, FBC RE4101.4
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-09-14 Cont ID  
Sent By cthroop Date 2017-09-14 Time 06:54 Rev Time 0.00
Received By cthroop Date 2017-08-22 Time 14:13 Sent To  
Notes
2017-08-23 14:15:15R25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-08-23 Cont ID  
Sent By thunt Date 2017-08-15 Time 15:41 Rev Time 0.00
Received By lmarchan Date 2017-08-02 Time 11:02 Sent To  
Notes
2017-08-04 11:02:52R28

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2017-09-14 Cont ID  
Sent By cthroop Date 2017-09-14 Time 06:54 Rev Time 0.00
Received By cthroop Date 2017-09-14 Time 06:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-08-28 Cont ID  
Sent By gjohnson Date 2017-08-28 Time 18:58 Rev Time 0.00
Received By gjohnson Date 2017-08-28 Time 18:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-08-15 Cont ID  
Sent By thunt Date 2017-08-15 Time 15:40 Rev Time 0.00
Received By thunt Date 2017-08-15 Time 15:23 Sent To  
Notes
2017-08-15 15:41:18PROVIDE WATER HEATER SPECS ON-SITE AT TIME OF
 INSPECTION