Plan Review Stops For Permit 17080081 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-17 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-16 |
Time |
18:41 |
Sent To |
|
|
Notes |
2017-11-16 16:13:14 | TALKED TO RODNEY. HE SAID TO APPROVE BUILDING AND | | MECHANICAL REVIEWS WITH PROVISO. HE IS AWARE THAT | | REVISION FEES MAY APPLY AFTER PERMIT IS ISSUED. JG. | | | | | | BUILDING REVIEW APPROVED WITH PROVISO (PROVIDE | | INFORMATION PRIOR TO INSPECTIONS TO AVOID | | CONFLICTS/DELAYS), (PROVIDE 2 COPIES): | | 1- PROVIDE MANUFACTURER'S SPECS FOR BEDROOM #2 WINDOW | | SHOWING ALL EGRESS DIMENSIONS. | | 2- PROVIDE PRODUCT APPROVAL FOR: | | A) ROOF TILE ADHESIVE LISTED IN THE ROOF TILE NOA | | 16-0314.08 SUBMITTED. NOTE: SPECIFY PADDY SIZE. | | B) SLIDING GLASS DOORS INCLUDING SIZE FOR OPENING #4 | | AND INCLUDE FLORIDA PRODUCT APPROVAL COVER PAGE. | | C) EGRESS CASEMENT WINDOWS. | | 3- ARCHITECT TO APPROVE ALL PRODUCT APPROVALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-11-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-07 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-06 |
Time |
17:19 |
Sent To |
|
|
Notes |
2017-11-06 17:21:11 | RESIDENTIAL (R3) ADDITION/ALTERATION THIRD REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS THAT PERMIT MAY BE ISSUED AND CONTRACTOR WILL | | BRING REQUIRED INFORMATION PRIOR TO INSPECTIONS TO | | AVOID CONFLICTS/DELAYS. REVISION FEES MAY APPLY. THERE | | ARE NO FEES FOR PRODUCT APPROVALS SUBMITTAL, EXCEPT FOR | | CHANGES IN PRODUCT APPROVALS THAT WERE ALREADY | | APPROVED. CONTRACTOR TO ADVICE IN WRITING IF PROVISO | | OPTION IS PREFERRED AT THIS TIME. | | | | 1- BEDROOM #2 EGRESS WINDOWS. PROVIDE MANUFACTURER'S | | CUT SHEETS SHOWING THAT THE SPECIFIED WINDOW SIZE | | COMPLIES WITH ALL THE EGRESS REQUIREMENTS OF SEC. R310 | | FBC-RESIDENTIAL. | | RESPONSE: REPEAT COMMENT. MANUFACTURER'S INFORMATION | | FOR THE SINGLE HUNG WINDOW WAS NOT SUBMITTED. PROVIDE | | INFORMATION SHOWING THE SPECIFIED SIZE OF WINDOW. | | UNABLE TO VERIFY ALL EGRESS REQUIREMENTS. ONLY | | INFORMATION FOR THE CASEMENT WINDOW WAS PROVIDED. | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF TILE ADHESIVE THAT IS LISTED IN THE ROOF TILE | | NOA 16-0314.08 SUBMITTED. NOTE: CLEARLY SPECIFY PADDY | | SIZE TO VERIFY COMPLIANCE WITH THE REQUIRED ATTACHMENT | | RESISTANCE. COORDINATE WITH ROOF TILE NOA SUBMITTED. | | RESPONSE: REPEAT COMMENT. SAME NOA THAT WAS SUBMITTED | | THE FIRST TIME WAS RE-SUBMITTED. RTA-1 ADHESIVE NOA | | 16-0315.03 IS NOT LISTED IN THE CONCRETE TILE NOA | | SUBMITTED. IF CONTRACTOR WANTS TO USE THE RTA-1, THEN | | PROVIDE COMPLETE PACKAGE FOR BUILDING OFFICIAL REVIEW | | AND APPROVAL. CONTACT ME FOR ADDITIONAL INFORMATION. | | | | B) SLIDING GLASS DOORS SHOWING THE SIZES SPECIFIED ON | | PLANS. | | RESPONSE: REPEAT COMMENT. DRAWINGS (FLORIDA PRODUCT | | APPROVAL FL15726) SUBMITTED DON'T COVER THE SIZE OF | | DOOR #4. SEE MAXIMUM PANEL SIZE (+/- 5'-0" X 8'-0"). | | AND, NEED TO PROVIDE COMPLETE PRODUCT APPROVAL, | | INCLUDING THE FLORIDA PRODUCT APPROVAL COVER PAGE THAT | | CORRESPOND TO DRAWINGS SUBMITTED. | | | | C) EGRESS CASEMENT WINDOWS AS SPECIFIED FOR | | STUDY/BEDROOM. AND PROVIDE MANUFACTURER'S CUT SHEETS | | SHOWING COMPLIANCE WITH THE EGRESS REQUIREMENTS. | | RESPONSE: NO PRODUCT APPROVAL WAS SUBMITTED. PROVIDE | | COMPLETE PRODUCT APPROVAL, FLORIDA PRODUCT APPROVAL | | COVER PAGES AND CORRESPONDING DRAWINGS. | | | | 3- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. NOTE: | | ARCHITECT TO PLACE THE REVIEW STAMP ON THE FRONT OF THE | | COVER PAGE NOT ON THE BACK. THIS IS REQUIRED TO | | FACILITATE PROPER SCANNING OF ALL DOCUMENTS. | | | | 4- VALUATION WAS UPDATED TO =+/- $200,000. THE | | VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S | | OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS | | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. THE PERMIT FEE | | BALANCE IS $4,036.250. | | NOTE: VALUATION IS BASED ON THE FAIR MARKET VALUE FOR | | CONSTRUCTION. THE PROPOSED HOUSE HAS 2458 S.F. OF A/C | | AREA AND 440 S.F. OF NON A/C AREAS (GARAGE AND PORCH). | | WE USE THE ICC BUILDING VALUATION DATA (AUG. 2017) AS A | | REFERENCE FOR BUILDING VALUATION. ACCORDING TO THE ICC | | BUILDING VALUATION DATA THE AVERAGE COST PER SQUARE | | FOOT TO BUILD A HOUSE IS $116.15 FOR A/C AREA AND | | $45.95 FOR NON A/C AREAS. BASED ON THIS NUMBERS THE | | AVERAGE VALUE TO BUILD THIS HOUSE IS $305,700. BASED ON | | THE PLANS SUBMITTED, THE EXISTING HOUSE IS ALMOST | | COMPLETELY DEMOLISHED INCLUDING THE ROOF. ONLY SOME | | EXTERIOR WALLS ARE LEFT STANDING. THAT'S WHY A | | CONSERVATIVE VALUE OF $200,000 WAS ESTIMATED. THIS IS | | AN AVERAGE OF $69 PER SQUARE FOOT TO REBUILD THIS | | HOUSE. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS... | | *****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | DRAWING. DON'T STAPLE OLD DRAWINGS TO RESUBMITTED SET. | | SUBMIT OLD DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION. | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-17 |
Time |
17:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-17 |
Time |
12:49 |
Sent To |
|
|
Notes |
2017-10-12 14:17:04 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | RESPONSE: REPEAT COMMENT. NOT RESPONSE AT ALL. | | | | 2- ALL PLANS NEED THE ORIGINAL SIGNATURE (NOT COPY) OF | | THE ARCHITECT. FAC 61G1-16.003. | | RESPONSE: REPEAT COMMENT. ONLY THE SHEETS THAT WERE | | REVISED HAD THE ARCHITECT'S ORIGINAL SEAL AND | | SIGNATURE. OTHER SHEETS NEED TO HAVE THE ARCHITECT'S | | ORIGINAL SEAL AND SIGNATURE AS WELL. | | | | 3- PROVIDE ENERGY CALCULATIONS. SEC. R101.4.3 | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | RESPONSE: THIS IS THE FIRST REVIEW OF THE ENERGY | | CALCULATIONS. THE FOLLOWING NEEDS TO BE ADDRESSED: | | A) FORM 405-2014 SUBMITTED NEEDS TO BE CERTIFIED AND | | DATED AT THE BOTTOM BY THE OWNER OR LEGALLY DESIGNATED | | AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | B) COOLING AND HEATING INFORMATION DOESN'T MATCH | | INFORMATION SHOWN ON THE EQUIPMENT SIZING CALCULATIONS | | AND A/C PLAN. REVISE AS REQUIRED TO MATCH. NOTE: | | COORDINATE WITH MECHANICAL REVIEW COMMENTS. SEC. | | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | | | C) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING THE BUILDER NAME AS REQUIRED BY SEC. | | R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | D) PAGE 2 OF 4 SPECIFIES AN ATTIC VENT RATIO OF 1/300. | | TYPICALLY, THE VENT RATIO IS 1/150. ARCHITECTURAL PLANS | | DON'T SHOW ANY ATTIC VENTILATION SHOWING COMPLIANCE | | WITH THE 1/300 VENT RATIO. PERSON PREPARING THE ENERGY | | CALCULATIONS TO PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW THE HOUSE IS TAKING THE | | 1/300 VENTILATION RATIO AS REQUIRED BY THE EXCEPTION ON | | SEC. R806.2 FBC-RESIDENTIAL, 5TH EDITION (2014). OR | | PERSON PREPARING THE ENERGY CALCULATIONS TO REVISE THE | | VENT RATIO AS REQUIRED. | | | | E) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY | | CONSERVATION. | | | | NOTE: | | LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND | | SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL | | BE REQUIRED FOR INSPECTION WHEN THE ENERGY CALCULATIONS | | ARE NOT USING THE DEFAULT FACTOR FOR GLAZING. AND, | | BLOWER DOOR TEST IS REQUIRED AFTER JULY 1, 2017. | | | | 4- BEDROOM #2 EGRESS WINDOWS. PROVIDE MANUFACTURER'S | | CUT SHEETS SHOWING THAT THE SPECIFIED WINDOW SIZE | | COMPLIES WITH ALL THE EGRESS REQUIREMENTS OF SEC. R310 | | FBC-RESIDENTIAL. | | RESPONSE: REPEAT COMMENT. MANUFACTURER'S INFORMATION | | WAS NOT SUBMITTED. PROVIDE INFORMATION SHOWING THE | | SPECIFIED SIZE OF WINDOW. UNABLE TO VERIFY ALL EGRESS | | REQUIREMENTS. | | | | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF TILE ADHESIVE THAT IS LISTED IN THE ROOF TILE | | NOA 16-0314.08 SUBMITTED. NOTE: CLEARLY SPECIFY PADDY | | SIZE TO VERIFY COMPLIANCE WITH THE REQUIRED ATTACHMENT | | RESISTANCE. COORDINATE WITH ROOF TILE NOA SUBMITTED. | | | | B) SLIDING GLASS DOORS SHOWING THE SIZES SPECIFIED ON | | PLANS. | | RESPONSE: DRAWINGS SUBMITTED DON'T COVER THE SIZE OF | | DOOR #4. SEE MAXIMUM PANEL SIZE. AND, NEED TO PROVIDE | | COMPLETE PRODUCT APPROVAL, INCLUDING THE FLORIDA | | PRODUCT APPROVAL COVER PAGE THAT CORRESPOND TO DRAWINGS | | SUBMITTED. | | | | C) ENTRY DOOR AS SHOWN ON PLANS. | | RESPONSE: INFORMATION SUBMITTED IS INCOMPLETE. PROVIDE | | THE FLORIDA PRODUCT APPROVAL COVER PAGE THAT | | CORRESPONDS TO DRAWINGS SUBMITTED. | | | | D) FIXED WINDOWS AS SPECIFIED ON PLANS. | | RESPONSE: REPEAT COMMENT. | | | | E) EGRESS CASEMENT WINDOWS AS SPECIFIED FOR | | STUDY/BEDROOM. AND PROVIDE MANUFACTURER'S CUT SHEETS | | SHOWING COMPLIANCE WITH THE EGRESS REQUIREMENTS. | | | | 6- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. NOTE: | | ARCHITECT TO PLACE THE REVIEW STAMP ON THE FRONT OF THE | | COVER PAGE NOT ON THE BACK. THIS IS REQUIRED TO | | FACILITATE PROPER SCANNING OF ALL DOCUMENTS. | | | | 7- THERE IS A RED TAG FOR DEMOLITION WORK WITHOUT | | PERMIT. PLEASE GET THE DEMOLITION PERMIT TO REVOKE | | EXPIRED DEMOLITION PERMIT APPLICATION # 16080126. SEC. | | 105.1 CITY AMENDMENTS. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL THE DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. REVISE VALUATION TO INCLUDE ALL WORK AND | | DESIGN PROFESSIONAL FEES. | | RESPONSE: PROVIDE COPY OF SIGNED CONTRACT INCLUDING THE | | DESIGN PROFESSIONAL FEES. | | | | ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS... | | *****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | DRAWING. DON'T STAPLE OLD DRAWINGS TO RESUBMITTED SET. | | SUBMIT OLD DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION. | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-08-22 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-08-21 |
Time |
17:41 |
Sent To |
|
|
Notes |
2017-08-21 18:13:59 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE: | | THERE IS A RED TAG FOR DEMOLITION WORK WITHOUT PERMIT. | | PLEASE GET THE DEMOLITION PERMIT TO CLOSE EXPIRED | | DEMOLITION PERMIT APPLICATION 16080126. | | | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | | | 2- ALL PLANS NEED THE ORIGINAL SIGNATURE (NOT COPY) OF | | THE ARCHITECT. FAC 61G1-16.003. | | | | 3- PROVIDE ENERGY CALCULATIONS. SEC. R101.4.3 | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | 4 SETBACK DIMENSIONS SHOWN ON THE ARCHITECTURAL SITE | | PLAN ON SHEET A-101 DON'T MATCH DIMENSIONS SHOWN ON THE | | SURVEY. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 5- NEED TO PROVIDE EGRESS WINDOWS FOR NEW STUDY/BEDROOM | | SHOWING COMPLIANCE WITH ALL THE REQUIREMENTS OF SEC. | | R310 FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 6- BEDROOM #2 EGRESS WINDOWS. PROVIDE MANUFACTURER'S | | CUT SHEETS SHOWING THAT THE SPECIFIED WINDOW SIZE | | COMPLIES WITH ALL THE EGRESS REQUIREMENTS OF SEC. R310 | | FBC-RESIDENTIAL. | | | | 7- CLARIFY ROOFING MATERIAL TO BE INSTALLED. PROPOSED | | WALL SECTION ON SHEET A-202 SPECIFIES METAL ROOFING , | | WHILE EXTERIOR ELEVATIONS SPECIFY BARREL TILE ROOF. | | REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 8- PROVIDE SPECIFICATIONS FOR THE GARAGE DOOR LEADING | | TO THE MAIN HOUSE. NEED TO SPECIFY SELF CLOSING DEVICE | | AS REQUIRED BY SEC. R302.5.1 FBC-RESIDENTIAL. | | NOTE: REVISE CODE SECTIONS CITED ON THE GARAGE | | SEPARATION NOTES ON SHEET A-202. SEE SEC. R302.5 AND | | R302.6 FBC-RESIDENTIAL FOR CORRECT CODE SECTION AND | | REVISE AS REQUIRED. | | | | 9- INFORMATION SHOWN ON THE INSULATION TABLE ON SHEET | | A-202 DOESN'T MATCH INFORMATION SHOWN ON THE WALL | | SECTION ON SAME SHEET. REVISE AS REQUIRED TO MATCH. SEE | | WALL INSULATION R-VALUE. ALSO, THE THICKNESS OF R-30 | | FIBERGLASS CEILING INSULATION IS 9-1/2" +/- NOT 6.5". | | REVISE AS REQUIRED. SEC. R103.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | 10- PROVIDE DETAIL/SPECS FOR INSULATION BETWEEN THE NEW | | GARAGE AND DINING A/C AREA. SEC. R103.2 FBC-ENERGY | | CONSERVATION. | | | | 11- SPECIFY ATTIC ACCESS LOCATION AND SIZE SHOWING | | COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL. | | | | 12- WIND LOAD INFORMATION ON SHEET S-201: | | A) REVISE THE WIND LOAD SPEED. THE WIND LOAD IS 170 MPH | | ULTIMATE WIND LOAD NOT 160MPH. SEC. R301.2.1 | | FBC-RESIDENTIAL. | | | | B) COMPONENTS AND CLADDING DESIGN PRESSURES ARE BASED | | ON A TRIBUTARY AREA OF 20S.F. THE EFFECTIVE TRIBUTARY | | AREA NEEDS TO BE THE ACTUAL TRIBUTARY AREA OR USE THE | | LOWEST TRIBUTARY AREA. SEE NOTE "C" OF TABLE R301.2(2) | | FBC-RESIDENTIAL. AND REVISE AS REQUIRED. COORDINATE | | DESIGN PRESSURES WITH DOOR AND WINDOW SCHEDULE ON SHEET | | A-401. SPECIFY THE DESIGN PRESSURES FOR THE OVERHEAD | | GARAGE DOOR. | | | | C) GRAVITY LOADING. SPECIFY THE ATTIC LIVE LOAD AS | | REQUIRED BY TABLE R301.5 FBC-RESIDENTIAL. NOTE: TAKE | | INTO CONSIDERATION NOTES "B" AND "G" AND IF THE ATTIC | | IS SERVED WITH FIXED STAIRS. | | | | 13- PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR THE | | OVERHEAD GARAGE DOOR STRUCTURAL BUCK DETAIL. SEC. | | R301.1 FBC-RESIDENTIAL. | | | | 14- SPECIFY CARBON MONOXIDE ALARMS BY THE | | BEDROOM/SLEEPING ROOMS IN THE REQUIRED LOCATIONS | | REQUIRED BY SEC. R15 FBC-RESIDENTIAL. | | | | 15- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING | | METHOD AS REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. | | IF SPECIFYING SCREWS, THEN SPECIFY SIZE AND NUMBER OF | | SCREWS. IF SPECIFYING ROOF TILE ADHESIVE, THEN ROOF | | TILE ADHESIVE PRODUCT APPROVAL IS REQUIRED. | | | | 16- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF COVERING AS SPECIFIED ON PLANS. COORDINATE WITH | | ITEM #7 ABOVE. | | | | B) ROOF TILE ADHESIVE IF SPECIFIED BY THE DESIGN OF | | RECORD. NOTE: SEE ROOFING PRODUCT APPROVAL FOR LISTED | | ADHESIVES. | | | | C) SLIDING GLASS DOORS SHOWING THE SIZES SPECIFIED ON | | PLANS. NOTE: DRAWINGS SUBMITTED ARE NOT LEGIBLE. THEY | | ARE TOO SMALL. PLEASE PRINT DRAWINGS ON THE LONGEST | | SIDE OF THE SHEET (PRINT THEM IN LANDSCAPE ORIENTATION | | TO USE FULL SHEET). | | | | D) ENTRY DOOR WITH SIDELITE AND TRANSOM AS SHOWN ON | | PLANS. | | | | E) OVERHEAD GARAGE DOOR. NOTE: DRAWINGS SUBMITTED ARE | | NOT LEGIBLE. THEY ARE TOO SMALL. PLEASE PRINT DRAWINGS | | ON THE LONGEST SIDE OF THE SHEET (PRINT THEM IN | | LANDSCAPE ORIENTATION TO USE FULL SHEET). | | | | F) SINGLE HUNG WINDOWS AS SHOWN ON PLANS. NOTE: | | DRAWINGS SUBMITTED ARE NOT LEGIBLE. THEY ARE TOO SMALL. | | PLEASE PRINT DRAWINGS ON THE LONGEST SIDE OF THE SHEET | | (PRINT THEM IN LANDSCAPE ORIENTATION TO USE FULL | | SHEET). | | | | G) HURRICANE SHUTTERS. SINGLE HUNG PRODUCT APPROVAL | | FL14911.21 SUBMITTED IS FOR NON-IMPACT WINDOWS. ALL | | WINDOWS AND DOORS WITH GLAZING NEED HURRICANE IMPACT | | PROTECTION. AND, PROVIDE COMPLETE INSTALLATION | | SCHEDULE. SEE CITY SAMPLE. | | | | H) WINDOW MULLIONS. AND, CLEARLY SPECIFY MULLION SIZE | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES. SEC. | | R301.1 FBC-RESIDENTIAL. | | | | I) FIXED WINDOWS AS SPECIFIED ON PLANS. | | | | J) SIMPSON STRUCTURAL CONNECTORS AS SPECIFIED ON PLANS | | AND ALL DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT | | APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED | | CONNECTOR OR DESIGNER OF RECORD TO LIST THE FLORIDA | | PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED | | CONNECTOR. | | | | 17- DESIGNER OF RECORD TO APPROVE ALL PRODUCT APPROVALS | | PRIOR TO SUBMITTAL AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | | | 18- PROVIDE SPECIFICATIONS FOR THE CORNER STEEL COLUMN | | LOCATED IN THE MATER BATHROOM BY THE FREE STANDING BATH | | TUB. SEC. R301.1 FBC-RESIDENTIAL. | | | | 19- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL THE DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. REVISE VALUATION TO INCLUDE ALL WORK AND | | DESIGN PROFESSIONAL FEES. | | | | ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS... | | *****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | DRAWING. DON'T STAPLE OLD DRAWINGS TO RESUBMITTED SET. | | SUBMIT OLD DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION. | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-16 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-16 |
Time |
09:51 |
Sent To |
B |
|
Notes |
2017-11-06 17:35:13 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-10-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-19 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-10-19 |
Time |
12:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-08-17 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-17 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-17 |
Time |
10:07 |
Sent To |
|
|
Notes |
2017-08-17 10:07:24 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. GENERAL ELECTRICAL NOTES, NOTE #10 STATES THAT THE | | MINIMUM WIRE SIZE SHALL BE #12, BUT PANEL SCHEDULE | | SHOWS CIRCUITS FED WITH #14. PROVIDE CORRECTION. FBC | | 107.2.1 | | 2. GENERAL ELECTRICAL NOTES, NOTE #27 STATES THAT "NM" | | SHALL NOT BE USED, BUT NOTE #7 OF ELECTRICAL NOTES | | STATES "ROMEX IS ACCEPTABLE". PROVIDE CORRECTION. FBC | | 107.2.1 | | 3. ELECTRICAL NOTES, NOTE #8 EXPLAINS WHERE AFCI | | PROTECTION SHOULD BE USED. HOWEVER, IT DOES NOT COVER | | ALL AREAS REQUIRED PER CODE: "ALL 120-VOLT, SINGLE | | PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING | | OUTLETS IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR | | SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI PROTECTION". | | PROVIDE CORRECTION. NEC 210.12; FBC RE3902.12 | | 4. ELECTRICAL NOTES, NOTE #17 STATES THAT LIGHTING IN | | CLOSETS SHALL COMPLY WITH 410.8. THIS CODE SECTION DOES | | NOT APPLY TO CLOSET LIGHTING. PROVIDE CORRECTION. NEC | | 410.16; FBC RE4003.12 | | 5. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | FBC EC R404.1 | | 6. OUTLETS ARE MISSING IN THE MASTER BEDROOM. | | RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL | | SPACE IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET. | | PROVIDE CORRECTION. NEC 210.52; FBC RE3901.2.1 | | 7. PLAN SHOWS A CHANDELIER ABOVE THE TUB IN MASTER | | BATH. THE CEILING HEIGHT IS SHOWN AS 10'7". NO PARTS OF | | CORD-CONNECTED LUMINAIRES, CHAIN-, CABLE-, OR | | CORD-SUSPENDED LUMINAIRES, LIGHTING TRACK, PENDANTS, OR | | CEILING-SUSPENDED (PADDLE) FANS SHALL BE LOCATED WITHIN | | A ZONE MEASURED 3 FEET HORIZONTALLY AND 8 FEET | | VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER | | STALL THRESHOLD. PROVIDE CORRECTION. NEC 410.10(D); FBC | | RE 4003.11 | | 8. LIGHT ABOVE SHOWER IN POWDER BATH IS SHOWN AS A | | STANDARD RECESS LIGHT. LIGHTING IN BATHTUB OR SHOWER | | AREAS SHALL BE SUITABLE FOR DAMP LOCATIONS. PROVIDE | | CORRECTION. NEC 410.10(D); FBC RE4003.11 | | 9. PROVIDE GFCI PROTECTED OUTLET ON REAR OF HOUSE. NEC | | 210.52(E); FBC RE3901.7 | | 10. ISLAND RECEPTACLES IN KITCHEN REQUIRED GFCI | | PROTECTION. NEC 210.8; FBC RE3902.6 | | 11. OUTLET FOR GARAGE DOOR OPENER REQUIRES GFCI | | PROTECTION. NEC 210.8; FBC RE3902.2 | | 12. SHOW LOCATIONS OF ALL PANELS AND THE SERVICE ON | | PLAN. FBC 107.2.1 | | 13. SHOW THE MECHANICAL EQUIPMENT ON PLAN, INCLUDING | | THE OUTLET REQUIRED FOR SERVICING OF EQUIPMENT. FBC | | 107.2.1, FBC RE3901.12; NEC 210.63 | | 14. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED | | SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | SUBMITTALS FOR POOL AND ALL LOW VOLTAGE SYSTEMS TO | | INCLUDE BUT NOT LIMITED TO FIRE ALARM, CCTV, PHONE AND | | DATA, WIRELESS SYSTEMS, ETC. FBC 105.1 | | 15. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. NEC 250.94; FBC RE3609.3 ADDITIONALLY, A 1/0 | | WIRE IS SPECIFIED FOR THE GROUNDING ELECTRODE | | CONDUCTOR, WHICH IS NOT TYPICAL FOR THIS SIZE SERVICE, | | ONLY A #4 WIRE IS REQUIRED. NEC 250.66; FBC RE TABLE | | 3603.1. RISER SHOWS A #6 EQUIPMENT GROUNDING CONDUCTOR | | (EGC) IN THE CONDUIT BETWEEN THE METER AND THE MAIN | | DISCONNECT. THE EGC IS ONLY INSTALLED AFTER THE FIRST | | MEANS OF DISCONNECT. PROVIDE CORRECTION. FBC RE3704.6; | | NEC 250.4, 250.6 | | 16. PANEL SCHEDULE SHOWS #8 ROMEX ON A 50 AMP BREAKER | | FEEDING THE OVEN AND WATER HEATER. #8 ROMEX IS NOT | | RATED FOR 50 AMPS. PROVIDE CORRECTION. NEC 334.80; FBC | | RE3705.4.4 | | 17. BREAKER FOR WATER HEATER SHOULD BE SIZED AT 125% OF | | LOAD. PROVIDE CORRECTION. NEC 422.13; FBC RE4101.5 | | 18. THERE IS NO CIRCUIT INCLUDED IN PANEL SCHEDULES FOR | | THE CONDENSING UNIT. ADD TO SCHEDULE AND IDENTIFY WIRE | | AND BREAKER SIZE. ADJUST LOAD CALCULATION IF NECESSARY. | | NEC 215.5, 408.4, 310.15(B)(16); FBC 107.2.1; FBC | | RE3701.2 | | 19. BREAKER FOR POOL PUMP SHOULD BE GFCI PROTECTED. | | PROVIDE CORRECTION. NEC 680.21(C); FBC RE4203.1.3 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-11-14 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-11-14 |
Time |
12:31 |
Sent To |
|
|
Notes |
2017-12-04 15:22:51 | HPB APPROVED 11-28-17 WITH CONDITION THAT BASE OF | | COLUMNS USE LOCAL STONE SIMILAR TO COQUINA | 2017-11-14 12:32:19 | APPROVED PENDING APPROVAL BY HPB 11/28/17 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2017-10-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-10-11 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-10-11 |
Time |
15:33 |
Sent To |
|
|
Notes |
2017-10-11 15:34:32 | STILL NO COA SUBMITTED. SEE COMMENTS FROM FIRST REVIEW. | | PLEASE CONTACT FRIEDERIKE MITTNER AT 822-1457 WITH | | QUESTIONS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-08-25 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-08-25 |
Time |
09:35 |
Sent To |
|
|
Notes |
2017-08-25 09:38:04 | SIGINIFICANT ALTERATION STO STRUCTURE IN HISTORIC | | DISTRICT. REQUIRES SUBMITTAL AND APPROVAL OF COA. | | INITAL STAFF REVIEW INDICATES PLANS MEET DESIGN | | GUIDELINES, HOWEVER, BAORD REVIEW IS REQUIRED. | | QUESTIONS, CONTACT: | | | | FRIEDERIKE MITTNER | | CITY HISTORIC PRESERVATION PLANNER AT 822-1457 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-11-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-17 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-16 |
Time |
16:05 |
Sent To |
|
|
Notes |
2017-11-16 16:12:17 | TALKED TO RODNEY. HE SAID TO APPROVE BUILDING AND | | MECHANICAL REVIEWS WITH PROVISO. HE IS AWARE THAT | | REVISION FEES MAY APPLY AFTER PERMIT IS ISSUED. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-11-16 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-27 |
Time |
14:32 |
Sent To |
|
|
Notes |
2017-11-14 12:31:21 | APPROVED PENDING APPROVAL AT HPB ON 11/28/17 | 2017-10-30 14:32:47 | R28 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-10-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-19 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-29 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-08-25 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-08-02 |
Time |
14:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2017-11-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-07 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-07 |
Time |
11:09 |
Sent To |
|
|
Notes |
2017-11-07 11:10:03 | $236.59 PAID. MU-2017-030431. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2017-10-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-18 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-18 |
Time |
09:20 |
Sent To |
|
|
Notes |
2017-10-18 09:20:58 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-08-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-08-21 |
Time |
18:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-08-21 |
Time |
18:19 |
Sent To |
|
|
Notes |
2017-08-21 18:19:58 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-17 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-17 |
Time |
12:15 |
Sent To |
|
|
Notes |
2017-11-16 16:13:27 | TALKED TO RODNEY. HE SAID TO APPROVE BUILDING AND | | MECHANICAL REVIEWS WITH PROVISO. HE IS AWARE THAT | | REVISION FEES MAY APPLY AFTER PERMIT IS ISSUED. JG. | | | | MECHANICAL REVIEW APPROVED WITH PROVISO (PROVIDE | | INFORMATION PRIOR TO INSPECTIONS TO AVOID | | CONFLICTS/DELAYS) (PROVIDE 2 COPIES): | | 1- A/C PLAN NEEDS TO SHOW COMPLIANCE WITH THE BALANCED | | RETURN AIR FOR ALL ROOMS REQUIRED BY SEC. M1602.4 | | FBC-RESIDENTIAL, 5TH EDITION (2014). SIZE OF TRANSFER | | DUCT SPECIFIED FOR THE MASTER BEDROOM, STUDY/BEDROOM | | AND BEDROOMS #2 AND #3 IS TOO SMALL. REVISE A/C PLAN AS | | REQUIRED. | | | | 2- EQUIPMENT SIZING CALCULATIONS SHOW A 4 TON A/C UNIT. | | CFM'S SHOWN ON THE A/C PLAN EXCEED THE CAPACITY OF THE | | EQUIPMENT SPECIFIED ON THE EQUIPMENT SIZING | | CALCULATIONS. REVISE CFM'S AS REQUIRED. SEC. R103.2 | | FBC-ENERGY CONSERVATION. | | NOTE: COORDINATE INFORMATION WITH PLANS SUBMITTED WITH | | THE EQUIPMENT SIZING CALCULATIONS. | | | | 3- MECHANICAL PLAN M-101 IS MISSING THE CFM'S FOR THE | | DINING ROOM. SEC. R103.2 FBC-ENERGY CONSERVATION. | | | | NOTE: | | WHEN THE AIR HANDLING UNIT IS LOCATED IN THE ATTIC, THE | | SERVICE PANEL NEED TO BE WITHIN 6 FEET OF THE ATTIC | | ACCESS AS REQUIRED BY SEC. R403.2.4 FBC-ENERGY | | CONSERVATION. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-11-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-07 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-07 |
Time |
14:26 |
Sent To |
|
|
Notes |
2017-11-07 14:40:58 | RESIDENTIAL (R3) ADDITION/ALTERATION THIRD MECHANICAL | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: | | MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS THAT PERMIT MAY BE ISSUED AND CONTRACTOR WILL | | BRING REQUIRED INFORMATION PRIOR TO INSPECTIONS TO | | AVOID CONFLICTS/DELAYS. REVISION FEES APPLY. | | CONTRACTOR TO ADVICE IN WRITING IF PROVISO OPTION IS | | PREFERRED AT THIS TIME. | | | | | | | | 1- A/C PLAN NEEDS TO SHOW COMPLIANCE WITH THE BALANCED | | RETURN AIR FOR ALL ROOMS REQUIRED BY SEC. M1602.4 | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | RESPONSE: | | A) SIZE OF TRANSFER DUCT SPECIFIED FOR THE MASTER | | BEDROOM IS TOO SMALL. SIZE NEEDS TO BE BE BASED ON THE | | TOTAL SUPPLY AIR THAT GOES INTO THE MASTER BEDROOM, | | INCLUDING THE CLOSETS AND BATHROOM. SEE EXCEPTION #3 OF | | SEC. M1602.4 FBC-RESIDENTIAL. NEED AT LEAST 19" DUCT | | SIZE (BASED ON THE SPECIFIED CFM'S) AND HAVING THE DOOR | | WITH AT LEAST AN UNRESTRICTED 1 INCH UNDERCUT. REVISE | | AS REQUIRED. REPEAT COMMENT. REVISED SIZE OF 14" | | DOESN'T COMPLY. NEED AT LEAST 19" DUCT. | | | | B) SIZE OF TRANSFER DUCT SPECIFIED FOR THE | | STUDY/BEDROOM AND BEDROOMS #2 AND #3 IS TOO SMALL. THE | | SIZE OF THE DUCT NEEDS TO BE 1-1/2 TIMES THE CROSS | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM AND HAVING THE DOOR WITH AT LEAST AN | | UNRESTRICTED 1 INCH UNDERCUT. SEE EXCEPTION #1 OF SEC. | | M1602.4 FBC-RESIDENTIAL. NEED AT LEAST 10" DUCT SIZE. | | REVISE AS REQUIRED. REPEAT COMMENT. SIZE WAS NOT | | REVISED. NEED AT LEAST 10" DUCT. | | | | C) EQUIPMENT SIZING CALCULATIONS SHOW A 4 TON A/C UNIT. | | CFM'S SHOWN ON THE A/C PLAN EXCEED THE CAPACITY OF THE | | EQUIPMENT SPECIFIED ON THE EQUIPMENT SIZING | | CALCULATIONS. REVISE CFM'S AS REQUIRED. SEC. R103.2 | | FBC-ENERGY CONSERVATION. | | NOTE: COORDINATE INFORMATION WITH PLANS SUBMITTED WITH | | THE EQUIPMENT SIZING CALCULATIONS. | | | | D) MECHANICAL PLAN M-101 IS MISSING THE CFM'S FOR THE | | DINING ROOM. SEC. R103.2 FBC-ENERGY CONSERVATION. | | | | NOTE: | | WHEN THE AIR HANDLING UNIT IS LOCATED IN THE ATTIC, THE | | SERVICE PANEL NEED TO BE WITHIN 6 FEET OF THE ATTIC | | ACCESS AS REQUIRED BY SEC. R403.2.4 FBC-ENERGY | | CONSERVATION. | | | | ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS... | | *****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | DRAWING. DON'T STAPLE OLD DRAWINGS TO RESUBMITTED SET. | | SUBMIT OLD DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION. | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-10-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-18 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-18 |
Time |
09:31 |
Sent To |
|
|
Notes |
2017-10-18 09:40:59 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND MECHANICAL | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- ALL PLANS NEED THE ORIGINAL SIGNATURE (NOT COPY) OF | | THE ARCHITECT. FAC 61G1-16.003. | | RESPONSE: REPEAT COMMENT. SHEET M-201 STILL SHOWS A | | COPY OF THE SIGNATURE. | | | | 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS AS | | REQUIRED BY SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH | | EDITION (2014). NOTE: MAKE SURE EQUIPMENT LISTED IN THE | | CALCULATIONS MATCH EQUIPMENT SHOWN ON THE A/C PLAN TO | | AVOID CONFLICTS/DELAYS. | | RESPONSE: | | A) EQUIPMENT SHOWN ON THE EQUIPMENT SIZING CALCULATIONS | | AND EQUIPMENT SHOWN ON DRAWING M-101 DOESN'T MATCH. | | REVISE AS REQUIRED TO MATCH. SEC. R403.6 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | B) CLARIFY WHY THE CALCULATIONS ARE DONE BASED ON 18 | | OCCUPANTS. THIS INFORMATION DOESN'T MATCH INFORMATION | | SHOWN ON THE ENERGY CALCULATIONS. ENERGY CALCULATIONS | | CALLS FOR 5 OCCUPANTS, WHICH IS MORE REALISTIC FOR A | | FOUR BEDROOM HOUSE. SEC. R403.6 FBC-ENERGY CONSERVATION | | DOESN'T ALLOW TO USE FACTORS THAT AFFECT THE PROPER | | EQUIPMENT SIZING. REVISE AS REQUIRED. | | | | 3- A/C PLAN NEEDS TO SHOW COMPLIANCE WITH THE BALANCED | | RETURN AIR FOR ALL ROOMS REQUIRED BY SEC. M1602.4 | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | RESPONSE: | | A) SIZE OF TRANSFER DUCT SPECIFIED FOR THE MASTER | | BEDROOM IS TOO SMALL. SIZE NEEDS TO BE BE BASED ON THE | | TOTAL SUPPLY AIR THAT GOES INTO THE MASTER BEDROOM, | | INCLUDING THE CLOSETS AND BATHROOM. SEE EXCEPTION #3 OF | | SEC. M1602.4 FBC-RESIDENTIAL. NEED AT LEAST 19" DUCT | | SIZE. REVISE AS REQUIRED. | | | | B) SIZE OF TRANSFER DUCT SPECIFIED FOR THE | | STUDY/BEDROOM AND BEDROOMS #2 AND #3 IS TOO SMALL. THE | | SIZE OF THE DUCT NEEDS TO BE 1-1/2 TIMES THE CROSS | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM AND HAVING THE DOOR WITH AT LEAST AN | | UNRESTRICTED 1 INCH UNDERCUT. SEE EXCEPTION #1 OF SEC. | | M1602.4 FBC-RESIDENTIAL. NEED AT LEAST 10" DUCT SIZE. | | REVISE AS REQUIRED. | | | | ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS... | | *****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | DRAWING. DON'T STAPLE OLD DRAWINGS TO RESUBMITTED SET. | | SUBMIT OLD DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION. | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-08-22 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-08-22 |
Time |
13:13 |
Sent To |
|
|
Notes |
2017-08-22 15:22:20 | RESIDENTIAL (R3) ADDITION/ALTERATION MECHANICAL REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- ALL PLANS NEED THE ORIGINAL SIGNATURE (NOT COPY) OF | | THE ARCHITECT. FAC 61G1-16.003. | | | | 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS AS | | REQUIRED BY SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH | | EDITION (2014). NOTE: MAKE SURE EQUIPMENT LISTED IN THE | | CALCULATIONS MATCH EQUIPMENT SHOWN ON THE A/C PLAN TO | | AVOID CONFLICTS/DELAYS. | | | | 3- A/C PLAN NEEDS TO SHOW COMPLIANCE WITH THE BALANCED | | RETURN AIR FOR ALL ROOMS REQUIRED BY SEC. M1602.4 | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 4- PROVIDE SPECIFICATIONS FOR THE CLOTHES DRYER | | EXHAUST. SEC. M1502 FBC-RESIDENTIAL. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS... | | *****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | DRAWING. DON'T STAPLE OLD DRAWINGS TO RESUBMITTED SET. | | SUBMIT OLD DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION. | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-11-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-11-15 |
Time |
18:11 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-11-15 |
Time |
16:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-10-18 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-18 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-10-18 |
Time |
15:59 |
Sent To |
|
|
Notes |
2017-10-18 17:23:12 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. KITCHEN IS MISSING ON RISER DIAGRAM. PER WPB AMEND | | TO FBC 107.3.5.3(11) | | | | PREVIOUS COMMENT NOT COMPLIED 2. A TEMPERATURE LIMITING | | DEVISE IS REQUIRED ON STAND ALONE TUB VALVE. PER FBC | | RES P2713.3 PLACE NOTE ON PLAN. | | | | 3. SEPARATE PERMIT REQUIRED FOR BACKFLOW PLACE NOTE ON | | PLAN. PER WPB UTILITIES DEPT. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-08-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-08-23 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-08-23 |
Time |
08:40 |
Sent To |
|
|
Notes |
2017-08-23 09:17:54 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. PLEASE PROVIDE WATER AND SANITARY RISER DIAGRAM. PER | | WPB AMEND TO FBC 107.3.5.3(11) | | | | 2. A TEMPERATURE LIMITING DEVISE IS REQUIRED ON STAND | | ALONE TUB VALVE. PER FBC RES P2713.3 | | | | 3. A DRAIN PAN AND PAN DRAIN ARE REQUIRED FOR THE WATER | | HEATER. PER FBC RES P2801.5 / P2801.5.2 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-17 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-17 |
Time |
12:12 |
Sent To |
|
|
Notes |
2017-11-16 16:13:37 | TALKED TO RODNEY. HE SAID TO APPROVE BUILDING AND | | MECHANICAL REVIEWS WITH PROVISO. HE IS AWARE THAT | | REVISION FEES MAY APPLY AFTER PERMIT IS ISSUED. JG. | | | | | | BUILDING REVIEW APPROVED WITH PROVISO (PROVIDE | | INFORMATION PRIOR TO INSPECTIONS TO AVOID | | CONFLICTS/DELAYS), (PROVIDE 2 COPIES): | | 1- PROVIDE PRODUCT APPROVAL FOR: | | A) ROOF TILE ADHESIVE LISTED IN THE ROOF TILE NOA | | 16-0314.08 SUBMITTED. NOTE: SPECIFY PADDY SIZE. | | | | 2- ARCHITECT TO APPROVE ALL PRODUCT APPROVALS. | | | | | | APPROVED ROOF TILE NOA 16-0314.08. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2017-11-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-07 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-07 |
Time |
14:23 |
Sent To |
|
|
Notes |
2017-11-07 14:25:14 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF TILE ADHESIVE THAT IS LISTED IN THE ROOF TILE | | NOA 16-0314.08 SUBMITTED. NOTE: CLEARLY SPECIFY PADDY | | SIZE TO VERIFY COMPLIANCE WITH THE REQUIRED ATTACHMENT | | RESISTANCE. COORDINATE WITH ROOF TILE NOA SUBMITTED. | | RESPONSE: REPEAT COMMENT. SAME NOA THAT WAS SUBMITTED | | THE FIRST TIME WAS RE-SUBMITTED. RTA-1 ADHESIVE NOA | | 16-0315.03 IS NOT LISTED IN THE CONCRETE TILE NOA | | SUBMITTED. IF CONTRACTOR WANTS TO USE THE RTA-1, THEN | | PROVIDE COMPLETE PACKAGE FOR BUILDING OFFICIAL REVIEW | | AND APPROVAL. CONTACT ME FOR ADDITIONAL INFORMATION. | | | | 2- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. NOTE: | | ARCHITECT TO PLACE THE REVIEW STAMP ON THE FRONT OF THE | | COVER PAGE NOT ON THE BACK. THIS IS REQUIRED TO | | FACILITATE PROPER SCANNING OF ALL DOCUMENTS. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2017-10-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-18 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-18 |
Time |
13:01 |
Sent To |
|
|
Notes |
2017-10-18 13:01:55 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF TILE ADHESIVE THAT IS LISTED IN THE ROOF TILE | | NOA 16-0314.08 SUBMITTED. NOTE: CLEARLY SPECIFY PADDY | | SIZE TO VERIFY COMPLIANCE WITH THE REQUIRED ATTACHMENT | | RESISTANCE. COORDINATE WITH ROOF TILE NOA SUBMITTED. | | | | 2- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. NOTE: | | ARCHITECT TO PLACE THE REVIEW STAMP ON THE FRONT OF THE | | COVER PAGE NOT ON THE BACK. THIS IS REQUIRED TO | | FACILITATE PROPER SCANNING OF ALL DOCUMENTS. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-08-22 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-08-22 |
Time |
07:50 |
Sent To |
|
|
Notes |
2017-08-22 14:33:38 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF COVERING AS SPECIFIED ON PLANS. | | | | B) ROOF TILE ADHESIVE IF SPECIFIED BY THE DESIGNER OF | | RECORD. NOTE: SEE ROOFING PRODUCT APPROVAL FOR LISTED | | ADHESIVES. | | | | 2- DESIGNER OF RECORD TO APPROVE ALL PRODUCT APPROVALS | | PRIOR TO SUBMITTAL AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-11-14 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-11-14 |
Time |
12:32 |
Sent To |
|
|
Notes |
2017-11-06 17:35:45 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-10-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-10-11 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-10-11 |
Time |
15:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-08-25 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-08-25 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|