Plan Review Details - Permit 17070995
Plan Review Stops For Permit 17070995 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-09-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-27 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-27 |
Time |
07:56 |
Sent To |
|
|
Notes |
2017-09-27 08:56:34 | BASED ON THE OFFICIAL ZONING MAP REFERRED TO IN SECTION | | 53-2 OF CHAPTER 53 OF THE CITY CODE OF WEST PALM BEACH, | | FLORIDA, 1962, ADOPTED JUNE 15, 1964, YOUR PROPERTY, | | LOCATED AT 527 18TH STREET, IS NOT LOCATED IN AN AREA | | OF QUESTIONABLE SOILS AND DOES NOT REQUIRE | | INVESTIGATION BY A GEOTECHNICAL ENGINEER WITH ITS | | SUBSEQUENT SOILS REPORT AND DENSITY TESTING. | | THIS ONLY RELIEVES YOU FROM THE STATUTORY REQUIREMENTS | | OF THE FLORIDA BUILDING CODE. THERE MAY BE OTHER | | ENTITIES, SUCH AS YOUR DESIGN PROFESSIONAL OR YOUR | | LENDING INSTITUTION THAT MAY REQUIRE THE ABOVE | | MENTIONED INVESTIGATION. | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-08-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-08-17 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-08-17 |
Time |
10:24 |
Sent To |
|
|
Notes |
2017-08-17 14:04:32 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE SOILS REPORT. | | | | 2. ROOFING PERMIT REQUIRED. | | | | 3. WINDOW SCHEDULE SPECIFIES PGT 700 SERIES WINDOWS. | | NOA 15-0204.01 SUBMITTED FOR REVIEW IS FOR AIR MASTER | | WINDOWS. PLEASE CLARIFY. | | | | 4. REF. PLAN PAGE S-3. NOTES STATE ROOF WIND PRESSURES | | ARE BASED ON FBC 2010. PROVIDE DESIGN WIND LOADS FOR | | ROOF BASED ON THE 2014 FBC 5TH ED. | | | | 5. WIND DESIGN LOADS FOR PROPOSED PLASTPRO DOORS DO NOT | | MEET THE CALCULATED DESIGN PRESSURE RATING FOR WALL | | AREA 4, SEE PLAN PAGE S-3. | | | | 6. ROOFING NOA 11-1122.04 IS EXPIRED. PROVIDE VALID NOA | | FOR ROOFING SYSTEM COMPONENTS. | | | | 7. REF. PLAN PAGE S-1. TYPO IN PRE-CAST LINTEL NOTES | | "POURED SOLID WITH 300 PSI CONCRETE". PLEASE CORRECT. | | | | R401.4 SOIL TESTS. | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | APPROVED METHOD. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | | | R301.2.1 WIND DESIGN CRITERIA. | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | GARAGE DOORS). | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING AND DOOR SUBMITTALS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-10-12 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-12 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-10-12 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-09-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-27 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-27 |
Time |
07:35 |
Sent To |
|
|
Notes |
2017-09-27 07:35:47 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT WERE ADDRESSED HAVE BEEN | | REMOVED, THE REMAINING ARE ITEMS NOT ADDRESSED | | SATISFACTORILY. ADDITIONALLY, THE PLAN IS REQUIRED TO | | BE SIGNED BY THE PERSON RESPONSIBLE FOR THE DESIGN. FS | | 481.229 | | | | | | 3. PROVIDE AFCI PROTECTION TO CODE. NEC 210.12; FBC | | RE3902.12, FBC 107.2.1 (THE NOTE PROVIDED REFERENCES | | THE 2008 NEC, WHICH IS NOT THE CURRENT CODE. | | ADDITIONALLY, AFCI PROTECTION IS REQUIRED IN MORE THAN | | JUST SLEEPING AREAS. CODE STATES: ALL 120-VOLT, SINGLE | | PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING | | OUTLETS IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR | | SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI PROTECTION. NEC | | 210.12; FBC RE3902.12) PROVIDE CORRECTION. | | 4. PROVIDE TAMPER RESISTANT OUTLETS TO CODE. NEC | | 406.12; FBC RE4002.14 (THE NOTE PROVIDED REFERENCES THE | | 2008 NEC, WHICH IS NOT THE CURRENT CODE. ALSO, THE CODE | | SECTION CITED, 406.11, IS NOT RELATED TO TAMPER | | RESISTANT OUTLETS.) PROVIDE CORRECTION. | | 5. WATER HEATER BREAKER IS TOO LARGE. PROVIDE | | CORRECTION. NEC 422.13 (RESPONSE TO COMMENTS STATES | | THAT THE PANEL SCHEDULE WAS CHANGED, HOWEVER, IT IS | | STILL SHOWING A 30 AMP BREAKER. AT 125% OF THE LOAD, | | THE PROPER SIZE BREAKER FOR THIS IS 25 AMP.) PROVIDE | | CORRECTION. | | 6. AHU UNIT IS SHOWN BEING FED BY #6 WIRE. IS THIS | | ROMEX, OR WIRING INSTALLED IN A CONDUIT? #6 ROMEX WIRE, | | WHICH IS TYPICAL IN RESIDENTIAL WIRING, IS NOT RATED | | FOR 60 AMPS. PROVIDE CORRECTION. NEC 334.80; FBC | | RE3705.4.4 (THE CORRECTION PROVIDED WAS TO CHANGE THE | | BREAKER SIZE TO 50 AMP. HOWEVER, WITH THE NEW | | MECHANICAL SUBMISSION, I SEE THAT THE AHU WILL HAVE A 5 | | KW HEAT STRIP. SO, THE PROPER SIZE BREAKER IS 30 AMP. | | ALSO, THE CU UNIT SHOWS A 40 AMP BREAKER IN PANEL, BUT | | THE SPECS STATE THAT THE MOCP IS 35 AMP. PROVIDE | | CORRECTION FOR BOTH UNITS.) | | 8. CLOSET LIGHT IS NOT SPECIFIED. PROVIDE DETAIL OF | | FIXTURE, OR NOTE TO COMPLY WITH CODE. NEC 410.16; FBC | | RE4003.12 (RESPONSE TO COMMENT STATES TO SEE NOTE # 6, | | BUT THERE IS NOTHING IN NOTE # 6 THAT RELATES TO CLOSET | | LIGHTING.) PROVIDE CORRECTION. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-08-10 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-10 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-10 |
Time |
10:50 |
Sent To |
|
|
Notes |
2017-08-10 10:50:35 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. RISER SHOWS 1/0 WIRE USED FOR A 200 AMP SERVICE. 1/0 | | WIRE IS NOT RATED FOR 200 AMPS. PROVIDE CORRECTION. NEC | | 215.2, 310.15; FBC RE3602.1 | | 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. INCLUDE ALL AVAILABLE GROUNDING ELECTODES. NEC | | 250.50, 250.94; FBC RE3609.3 | | 3.PROVIDE AFCI PROTECTION TO CODE. NEC 210.12; FBC | | RE3902.12, FBC 107.2.1 | | 4. PROVIDE TAMPER RESISTANT OUTLETS TO CODE. NEC | | 406.12; FBC RE4002.14 | | 5.. WATER HEATER BREAKER IS TOO LARGE. PROVIDE | | CORRECTION. NEC 422.13 | | 6. AHU UNIT IS SHOWN BEING FED BY #6 WIRE. IS THIS | | ROMEX, OR WIRING INSTALLED IN A CONDUIT? #6 ROMEX WIRE, | | WHICH IS TYPICAL IN RESIDENTIAL WIRING, IS NOT RATED | | FOR 60 AMPS. PROVIDE CORRECTION. NEC 334.80; FBC | | RE3705.4.4 | | 7. AHU UNIT APPEARS TO BE IN ATTIC. PROVIDE RECEPTACLE | | OUTLET AT OR NEAR THE APPLIANCE. FBC RESIDENTIAL | | M1305.1.3.1 | | 8. CLOSET LIGHT IS NOT SPECIFIED. PROVIDE DETAIL OF | | FIXTURE, OR NOTE TO COMPLY WITH CODE. NEC 410.16; FBC | | RE4003.12 | | 9. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | FBC EC R404.1 | | 10. SMOLE ALARMS SHOULD BE LOCATED AT LEAST 3 FEET FROM | | CEILING FAN BLADES OR MECHANICAL GRILL. PROVIDE | | CORRECTION. NFPA 72, 11.8.3.5 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-10-12 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-12 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-10-10 |
Time |
15:05 |
Sent To |
|
|
Notes |
2017-10-11 15:05:59 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-10-05 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-09-15 |
Time |
14:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-09-01 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-09-01 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-07-25 |
Time |
10:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
P |
Date |
2017-08-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-08-17 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-08-17 |
Time |
10:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-10-05 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-10-05 |
Time |
13:09 |
Sent To |
|
|
Notes |
2017-10-05 14:35:03 | PASS PROVISO | | REFER TO SECTION R403.2.4 AIR HANDLING UNITS. | | 2014 FLORIDA ENERGY CODE. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-09-01 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-09-01 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-09-01 |
Time |
12:49 |
Sent To |
|
|
Notes |
2017-09-01 14:54:30 | PLAN DENIED | | 1) REFER TO SECTION R403.2.4 AIR HANDLING | | UNITS. 2014 FLORIDA ENERGY CODE. | | 2) PROVIDE EQUIPMENT SCHEDULE ON PLAN. | | SECTION 107 FBC 2014 | | 3) PROVIDE DUCT SIZE FOR MASTER BEDROOM | | RETURN AIR. 107 FBC 2014 | | 4) PLAN IS HARD TO READ PLEASE MAKE PLAN MORE LEGIBLE. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-09-27 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-09-27 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-09-27 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-08-18 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-08-18 |
Time |
15:56 |
Sent To |
M |
|
Notes |
2017-08-18 16:21:01 | WATER HEATER RELIEF AND PAN DRAIN LINE MUST COMPLY WITH | | 504.6 THRU 504.7.2 | | | | | | TIM HUNT | | PLUMBING INSPECTOR / PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6696 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2017-09-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-27 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-27 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-08-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-08-17 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-08-17 |
Time |
10:25 |
Sent To |
|
|
Notes |
2017-08-17 13:45:22 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. NOA 11-1122.04 HAS EXPIRED. PROVIDE CURRENT NOA FOR | | PROPOSED ROOFING. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-10-03 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2017-10-03 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2017-10-03 |
Time |
12:08 |
Sent To |
|
|
Notes |
2017-10-03 12:10:13 | FRONT SETBACK SHALL BE MEASURE FROM THE HOUSE NOT THE | | PORCH. | | | | ANGELLA VANN | | PLANNING & ZONING ADMINISTRATOR | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2017-09-26 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2017-09-26 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
awooten |
Date |
2017-09-25 |
Time |
|
Sent To |
|
|
Notes |
2017-09-25 15:26:06 | ************ZONING REVIEW********************** | | | | PLEASE SHOW THE FOLLOWING ON A SITE PLAN. | | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING. | | A. FRONT: 25 FEET; | | B. CORNER: 12.5 FEET; TEN FEET IF LOT IS LESS THAN 60 | | FEET WIDE; | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH WHICHEVER | | IS LESS; | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | THIS PROPERTY WOULD BE REQUIRED TO HAVE A 12.5 FOOT | | SETBACK ON THE CORNER SIDE AND A MINIMUM FIVE FOOT | | SETBACK ON THE WEST SIDE. | | | | ---- | | | | A SEPARATE LANDSCAPE AND IRRIGATION PLAN IS ALSO | | REQUIRED INDICATING THE FOLLOWING: | | | | SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION PLAN SHOWING | | COMPLIANCE WITH LANDSCAPE CODE: | | | | SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. | | | | THE DRIVEWAY REQUIRES A SEPARATE PERMIT. | | | | PLEASE LET ME KNOW WHAT QUESTIONS YOU MAY HAVE. | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-08-09 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2017-08-09 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
awooten |
Date |
2017-08-02 |
Time |
16:12 |
Sent To |
|
|
Notes |
2017-08-09 13:13:22 | ************ZONING REVIEW********************** | | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING. | | A. FRONT: 25 FEET; | | B. CORNER: 12.5 FEET; TEN FEET IF LOT IS LESS THAN 60 | | FEET WIDE; | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH WHICHEVER | | IS LESS; | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | THIS PROPERTY WOULD BE REQUIRED TO HAVE A 12.5 FOOT | | SETBACK ON THE CORNER SIDE AND A MINIMUM FIVE FOOT | | SETBACK ON THE WEST SIDE. | | | | A SEPARATE LANDSCAPE AND IRRIGATION PLAN IS ALSO | | REQUIRED INDICATING THE FOLLOWING: | | | | SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION PLAN SHOWING | | COMPLIANCE WITH LANDSCAPE CODE: | | | | SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. | | | | THE DRIVEWAY REQUIRES A SEPARATE PERMIT. | | | | PLEASE LET ME KNOW WHAT QUESTIONS YOU MAY HAVE. | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] | | |
|
|
|