Plan Review Stops For Permit 17070636 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-13 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-13 |
Time |
09:53 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-22 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-22 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-08-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-04 |
Time |
19:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-04 |
Time |
18:36 |
Sent To |
|
|
Notes |
2017-08-04 19:02:21 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE WRONG ADDRESS IS SPECIFIED IN THE TITLE BLOCK. | | FAC 61G15-23.002 | | | | 2) THE CODE TABULATION IS INCORRECT FOR THE OCCUPANCY | | USE, THE OCCUPANCY GROUP AND THE TYPE OF CONSTRUCTION. | | THE OCCUPANCY TYPE IS TOWNHOUSE, THE OCCUPANCY GROUP IS | | R3 AND THE TYPE OF CONSTRUCTION IS VB. FBC 107.2.1 | | | | 3) PLEASE CLARIFY WHAT IS MEANT BY RETAIL BATHROOMS, | | WHICH IS LISTED WITH ITEM #5 UNDER SCOPE OF WORK. FBC | | 107.2.1 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-11-08 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-08 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-08 |
Time |
09:17 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-08-21 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-21 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-21 |
Time |
14:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-08-01 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-01 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-01 |
Time |
12:36 |
Sent To |
|
|
Notes |
2017-08-01 12:36:01 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ADDRESS ON PLAN DOES NOT MATCH THE ADDRESS ON PERMIT | | APPLICATION. PROVIDE PLAN WITH CORRECT ADDRESS. FBC | | 107.2.1 | | 2. PROVIDE AFCI PROTECTION FOR NEW SMOKE ALARMS SHOWN | | ON PLAN. A NOTE WILL SUFFICE. NEC 210.12 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-13 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-06 |
Time |
15:47 |
Sent To |
|
|
Notes |
2017-11-07 15:48:06 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-22 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-18 |
Time |
12:44 |
Sent To |
|
|
Notes |
2017-08-21 12:44:41 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-08-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-04 |
Time |
19:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-07-17 |
Time |
09:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-13 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-13 |
Time |
11:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-22 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-22 |
Time |
13:26 |
Sent To |
|
|
Notes |
2017-08-22 14:19:53 | THE PLANS STATE THAT ONLY THE A/C GRILLS ARE BEING | | CHANGED. A MECHANICAL PERMIT IS NOT REQUIRED TO REPLACE | | A/C GRILLS. A MECHANICAL PERMIT APPLICATION WAS | | SUBMITTED AND THE WORK DESCRIPTION ON THE PERMIT | | APPLICATION IS TO REPLACE THE A/C AND GRILLS. PLEASE | | CLARIFY. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-08-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-04 |
Time |
19:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-04 |
Time |
19:02 |
Sent To |
|
|
Notes |
2017-08-04 19:12:20 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY MECHANICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) A MECHANICAL PERMIT APPLICATION WAS SUBMITTED. THE | | DESCRIPTION OF WORK ON THE APPLICATION IS TO REPLACE | | THE A/C AND GRILLS PER PLANS. THE PLANS THAT WERE | | SUBMITTED STATE THAT THERE IS NO MECHANICAL WORK. | | PLEASE CLARIFY. FBC 107.2.1 | | | | 2) PLEASE CLARIFY THE MECHANICAL SCOPE OF WORK AND | | SUBMIT HVAC PLANS AND ANY OTHER CONSTRUCTION DOCUMENTS | | THAT MAY BE REQUIRED. FBC - 107.3.5.3 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-13 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-13 |
Time |
11:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-22 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-22 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-08-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-04 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-04 |
Time |
18:49 |
Sent To |
|
|
Notes |
|
|