Plan Review Details - Permit 17070443
Plan Review Stops For Permit 17070443
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-08-02 Cont ID  
Sent By jleahy Date 2017-08-02 Time 08:38 Rev Time 0.00
Received By jleahy Date 2017-08-02 Time 08:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-08-02 Cont ID  
Sent By tklarge Date 2017-08-02 Time 14:04 Rev Time 0.00
Received By tklarge Date 2017-08-02 Time 14:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-08-02 Cont ID  
Sent By jleahy Date 2017-08-02 Time 08:38 Rev Time 0.00
Received By jleahy Date 2017-07-28 Time 16:22 Sent To  
Notes
2017-07-31 16:22:20RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-24 Cont ID  
Sent By tklarge Date 2017-07-24 Time 10:25 Rev Time 0.00
Received By tklarge Date 2017-07-12 Time 12:52 Sent To  
Notes
2017-07-13 12:52:48PLUMB -$5000

Review Stop P PLUMBING
Rev No 3 Status N Date 2017-08-02 Cont ID  
Sent By tklarge Date 2017-08-02 Time 14:03 Rev Time 0.00
Received By tklarge Date 2017-08-02 Time 14:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-08-01 Cont ID  
Sent By tklarge Date 2017-08-01 Time 14:08 Rev Time 0.00
Received By tklarge Date 2017-08-01 Time 11:45 Sent To  
Notes
2017-08-01 12:33:131) SUBMIT 2 SETS OF PROFESSIONALLY DRAWN PLANS THAT
 CLEARLY REFLECTS THE ENTIRE SCOPE OF WORK TO BE DONE
 INCLUDING ANY BUILDING, ELECTRICAL OR MECHANICAL WORK.
 WPB AMEND. TO FBC SECS. 107.1, 107.2.1. 2ND REQUEST
 2) SHOW THE PROPOSED TYPE OF OCCUPANCY ON THE PLANS PER
 THE FBC SEC.302.1. 2ND REQUEST.
 3) INDICATE THE OCCUPANT LOAD OF THIS SPACE PER THE FBC
 SEC.1004.1.2.2ND REQUEST.
 4) IS THIS A CHANGE OF OCCUPANCY PER THE FBC- EXISTING
 BUILDING CODE SEC.1001.3. INDICATE THE PREVIOUS
 OCCUPANCY OF THE SPACE ON THE PLANS. THE SUBMITTED
 PLANS MARKED "FOR REFERENCE ONLY" DO NOT CONTAIN THIS
 REQUIRED INFORMATION. 2ND REQUEST.
 5) SUBMIT A WATER RISER DIAGRAM FOR THE NEW PLUMBING
 WORK. WPB AMEND. TO FBC SEC. 107.3.5.1.3. 2ND REQUEST.
  
 I SUGGEST SETTING UP A MEETING WITH ME TO DISCUSS THE
 PLAN REVIEW COMMENTS ONCE THE REVIEW IS COMPLETE.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-07-24 Cont ID  
Sent By tklarge Date 2017-07-24 Time 10:25 Rev Time 0.00
Received By tklarge Date 2017-07-24 Time 09:48 Sent To  
Notes
2017-07-24 10:25:371) SUBMIT 2 SETS OF PROFESSIONALLY DRAWN PLANS THAT
 CLEARLY REFLECTS THE ENTIRE SCOPE OF WORK TO BE DONE
 INCLUDING ANY BUILDING, ELECTRICAL OR MECHANICAL WORK.
 WPB AMEND. TO FBC SECS. 107.1, 107.2.1.
 2) SHOW THE PROPOSED TYPE OF OCCUPANCY ON THE PLANS PER
 THE FBC SEC.302.1.
 3) INDICATE THE OCCUPANT LOAD OF THIS SPACE PER THE FBC
 SEC.1004.1.2.
 4) IS THIS A CHANGE OF OCCUPANCY PER THE FBC- EXISTING
 BUILDING CODE SEC.1001.3.? INDICATE THE PREVIOUS
 OCCUPANCY OF THE SPACE ON THE PLANS.
 5) SUBMIT A SANITARY AND WATER RISER DIAGRAM FOR THE
 NEW PLUMBING WORK. WPB AMEND. TO FBC SEC. 107.3.5.1.3.
 A VENT IS REQUIRED ON THE SUMP PER FBC 712.3.2.
 6) THE WATER HEATER RELIEF LINE SHALL DISCHARGE THROUGH
 AN AIR GAP LOCATED IN THE SAME ROOM AS THE WATER
 HEATER. FBC-PLUMBING SEC.504.6.
 7) SUBMIT A FLOOR PLAN SHOWING THE LOCATION OF THE
 EXISTING ACCESSIBLE TOILET ROOM AS NOTED ON THE
 APPLICATION.WPB AMEND. TO FBC SEC. 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  