Plan Review Details - Permit 17070439
Plan Review Stops For Permit 17070439
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-08-08 Cont ID  
Sent By rmcdouga Date 2017-08-08 Time 07:20 Rev Time 0.00
Received By rmcdouga Date 2017-08-08 Time 06:42 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-07-21 Cont ID  
Sent By rmcdouga Date 2017-07-21 Time 18:43 Rev Time 0.00
Received By rmcdouga Date 2017-07-21 Time 18:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-08-08 Cont ID  
Sent By rmcdouga Date 2017-08-08 Time 07:21 Rev Time 0.00
Received By rmcdouga Date 2017-08-08 Time 06:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-07-21 Cont ID  
Sent By rmcdouga Date 2017-07-21 Time 18:43 Rev Time 0.00
Received By rmcdouga Date 2017-07-21 Time 18:43 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-07-21 Cont ID  
Sent By tklarge Date 2017-07-21 Time 10:52 Rev Time 0.00
Received By tklarge Date 2017-07-21 Time 10:51 Sent To  
Notes
2017-07-21 10:52:18A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A GAS PERMIT IS REQUIRED FOR A CONTRACTOR TO
 PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS THAT
 REFLECT THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB
 AMEND. TO FBC SEC.107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-08-10 Cont ID  
Sent By tklarge Date 2017-08-10 Time 09:09 Rev Time 0.00
Received By tklarge Date 2017-07-31 Time 15:25 Sent To  
Notes
2017-08-01 15:25:30RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-21 Cont ID  
Sent By rmcdouga Date 2017-07-21 Time 18:44 Rev Time 0.00
Received By rmcdouga Date 2017-07-12 Time 12:50 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-08-10 Cont ID  
Sent By tklarge Date 2017-08-10 Time 09:09 Rev Time 0.00
Received By tklarge Date 2017-08-10 Time 08:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-07-21 Cont ID  
Sent By tklarge Date 2017-07-21 Time 11:01 Rev Time 0.00
Received By rmcdouga Date 2017-07-21 Time 10:31 Sent To  
Notes
2017-07-21 11:00:571) THE PIPING SCHEMATIC ON SHT. 2 OF 3 SHOWS ONE OF THE
 MAIN DRAINS FOR THE POOL CONNECTED TO THE POOL PIPING
 SUCTION AND ROUTING THROUGH THE FILTER, ETC., AND THE
 PIPING PLAN VIEW SHOWS THE SAME MAIN DRAIN PIPING
 ROUTED THROUGH A SEPARATE PUMP TO THE WATER FEATURE.
 THIS ALSO DOES NOT SHOW THIS WATER BEING FILTERED OR
 HEATED AS SHOWN ON THE PIPING SCHEMATIC. THE SAME THING
 OCCURS FOR THE RETURN LINES. CLARIFY.
 2) INDICATE WHAT THE LETTER "J" REPRESENTS ON THE POOL
 PLAN PIPING VIEW.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2017-08-04 Cont ID  
Sent By njwira Date 2017-08-04 Time 16:53 Rev Time 0.00
Received By njwira Date 2017-08-02 Time 08:55 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-07-14 Cont ID  
Sent By rmcdouga Date 2017-07-21 Time 18:44 Rev Time 0.00
Received By njwira Date 2017-07-13 Time 15:45 Sent To  
Notes
2017-07-14 16:11:467/14/17- FAILED
  
 PLEASE INDICATE ON THE SURVEY WHERE THE POOL EQUIPMENT
 IS GOING
  
  
 PLEASE CONTACT
 NATHAN WIRA- ZONING TECHNICIAN
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING
 DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST.
 WEST PALM BEACH, FL 33402
 OFFICE HOURS: M-F 8AM - 5PM
 (561)822-1442
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved