Plan Review Stops For Permit 17070341 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-03-19 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-03-01 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-10-06 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-10-06 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-10-06 |
Time |
09:25 |
Sent To |
|
|
Notes |
2017-10-06 09:37:14 | 2ND REVIEW: FBC 2014 5TH ED | | CITY CODE SECTION 78-490 | | | | APPROVED PENDING APPROVAL BY OTHER DIVISIONS & NOTE A | | BUILDING PERMIT APPLICATION IS REQUIRED IN ORDER TO | | CAPTURE THE CONTRACTOR INFORMATION. | | | | PENDING ENGINEERING APPROVAL, PLAN SHOWS CONNECTIONS TO | | STREET WHICH I UNDERSTAND IS NOT PERMITTED BY THE | | ENGINEERING DEPARTMENT. SPOKE WITH MATT LEBLANC AND | | ASKED THAT HE PROVIDE THE CALCULATIONS FOR WIND | | RESISTANCE TO THE STANDARD INDICATED ON THE PLAN IF THE | | DESIGN REMAINS THE SAME. FURTHER ASKED LEBLANC TO | | PROVIDE THE RECOMMENDED FORECASTED WIND RESISTANCE TO | | ALLOW FOR A WIND SPEED REMOVAL LIMIT FOR AN ANTICIPATED | | REMOVABLE RE-DESIGN. | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-09-13 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-09-13 |
Time |
10:32 |
Sent To |
|
|
Notes |
2017-09-13 15:52:36 | 1ST REVIEW: FBC 2014 5TH ED | | CITY CODE SECTION 78-490 | | | | NOT APPROVED, SEE BELOW: | | | | 1) ALTHOUGH YOU PROVIDED A PARKLET PERMIT APPLICATION, | | PLEASE ADDITIONALLY PROVIDE A BUILDING PERMIT | | APPLICATION FORM WITH CONTRACTOR AND OWNER INFORMATION | | AND SIGNATURES. LIST THE CITY OF WEST PALM BEACH IN BOX | | 9 ON THE REAR OF THE APPLICATION. | | | | 2) PROVIDE TWO SETS OF PLANS, ONLY ONE WAS FOUND. PLANS | | SHALL BE SIGNED AND SEALED BY THE DESIGNER OF RECORD | | PURSUANT TO FLORIDA ADMINISTRATIVE CODE RULE 61G1. | | | | 3) CITY CODE 78-497 (B)()C. - WIND RESISTANCE - SPECIFY | | THE WIND RESISTANCE STANDARD UTILIZED IN THE DESIGN OF | | THE PARKLET. PROVIDE DETAILS FOR FASTENING SUCH AS NAIL | | TYPE & SPACING, CONNECTORS AND CONNECTION TO EARTH. IT | | APPEARS THERE IS NOT INTENT TO DESIGN FOR WIND | | RESISTANCE PURSUANT TO FBC CHAPTER 16 FOR THE LOCATION | | AS RISK CATEGORY II BUT REATHER FOR A LESSER WIND | | RESISTANCE WITH INTEND TO REMOVE IN THE EVENT OF | | FORCASTED HIGH WINDS. IF THE LATER, PROVIDE DETAILS FOR | | THE MAXIMUM WIND DESIGN. FOR EXAMPLE, IF THE INTENT IS | | TO REMOVE PRIOR TO FORECASTED 75 MPH WINDS, PROVIDE A | | DESIGN CAPABLE OF WITHSTANDING 90 MPH WINDS AND PROVIDE | | THE REMOVAL PLAN. | | | | 4) CITY CODE 78-497 (B)(1)F. - ACCESSIBILITY - PLEASE | | INDICATE THE INTENT TO COMPLY WITH FBC ACCESSIBILITY | | CHAPTER 3 AS TO APPROACH, GROUND SURFACES, OPENINGS IN | | FLOOR SURFACES, CHANGES IN LEVEL, AND TURNING SPACE, | | MANEUVERING, AND CLEARANCES AND TABLE TOP HEIGHTS PER | | CHAPTER 3. ADDITIONALLY, PROVIDE A SEATING PLAN TO SHOW | | COMPLIANCE WITH FBC ACCESSIBILITY TABLE 221.2.1.1 | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-03-15 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-03-15 |
Time |
09:03 |
Sent To |
|
|
Notes |
2018-03-19 09:04:40 | APPROVED BY GRP |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2017-10-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-10-12 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-10-12 |
Time |
17:34 |
Sent To |
|
|
Notes |
2017-10-16 17:34:51 | REVIEW PERFORMED BY GORDON PATRIE AND WAS NOTED ON | | PLANS. A SCAN OF PLANS WILL BE SENT TO THE APPLICANT. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-08-18 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-08-18 |
Time |
10:30 |
Sent To |
|
|
Notes |
2017-09-13 10:31:14 | REVIEW PERFORMED BY GORDON PATRIE AND WAS NOTED ON | | PLANS. A SCAN OF PLANS WILL BE SENT TO THE APPLICANT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-03-19 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-03-01 |
Time |
14:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-10-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-10-16 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-09-19 |
Time |
09:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-03-09 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2018-03-09 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2018-03-09 |
Time |
10:49 |
Sent To |
|
|
Notes |
2018-03-09 13:39:17 | PROVISO: 1. TABLES AND CHAIRS REMAINING ON SIDEWALK | | SHALL PROVIDE FOR A MINIMUM WIDTH OF 54 INCHES OF | | UNOBSTRUCTED PATH FOR PEDESTRIANS. | | 2. BAMBOO STRIPS SHALL NOT PROJECT UP MORE THAN 48 | | INCHES FROM THE PARKLET BASE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-10-06 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-10-06 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2017-10-06 |
Time |
13:57 |
Sent To |
B |
|
Notes |
2017-10-06 13:58:32 | PROVISO: INSURANCE, BOND, AND FEES SHALL BE PROVIDED | | BEFORE ISSUANCE OF PARKLET PERMIT. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-08-10 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-08-10 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2017-08-10 |
Time |
15:07 |
Sent To |
ENG-P |
|
Notes |
2017-08-10 15:08:46 | 1. THE PARKLET SHALL MEET SETBACK REQUIREMENT. | | A. 18 INCHES FROM THE DRIVE LANE. | | B. 2 FEET FROM THE PARKING EDGE. | | 2. PROVIDE DETAILS ON THE PLANT MATERIALS TO BE USED. | | 3. PARKLETS REQUIRE DELINEATORS NOT BOLLARDS, PLEASE | | CHANGE. | | 4. ANY OVERHEAD FIXTURES SHALL BE SHOWN ON PLANS. | | 5. INSURANCE, BOND, AND FEES SHALL BE PROVIDED BEFORE | | ISSUANCE OF PARKLET PERMIT. | | |
|
|