Plan Review Details - Permit 17070265
Plan Review Stops For Permit 17070265 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-18 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-08-18 |
Time |
11:55 |
Sent To |
|
|
Notes |
2017-08-18 12:21:01 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17070265 | | ADD: 501 S. FLAGLER DR. SUITE : 302 | | CONT: ANDERSON MOORE CONSTRUCTION | | TEL: 561-308-1590 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: FRI. AUG. 18/ 2017 | | ACTION: BUILDING PROVISO | | | | 1) PROVISO: 2014 ACCESSIBILITY CODE SECTION 404.2.4 | | MANEUVERING CLEARANCES, MINIMUM 18 INCHES | | LATCH SIDE OF DOOR. TABLE 404.2.4.1 AND FIGURE | | 404.2.4.1(A). | | | | 2) PROVISO: POCKET DOORS, DOORS ARE IDENTIFIED AS 313B | | & 314B. | | 2014 ACCESSIBILITY CODE 404.2.7 DOOR HARDWARE. WHERE | | SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING | | HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. | | HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE | | PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4. | | OPERABLE PARTS. | | 2014 ACCESSIBILITY CODE 309.4 OPERATION. OPERABLE PARTS | | SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE | | TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE | | FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 | | POUNDS MAXIMUM. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-08-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-04 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-08-04 |
Time |
07:45 |
Sent To |
|
|
Notes |
2017-08-04 08:52:04 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17070265 | | ADD: 501 S. FLAGLER DR. SUITE : 302 | | CONT: ANDERSON MOORE CONSTRUCTION | | TEL: 561-308-1590 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: THURS. AUG. 04/ 2017 | | ACTION: BUILDING PROVISO | | | | 1) PROVISO: 2014 ACCESSIBILITY CODE SECTION 404.2.4 | | MANEUVERING CLEARANCES, MINIMUM 18 INCHES | | LATCH SIDE OF DOOR. TABLE 404.2.4.1 AND FIGURE | | 404.2.4.1(A). | | | | 2) PROVISO: POCKET DOORS, DOORS ARE IDENTIFIED AS 313B | | & 314B. | | 2014 ACCESSIBILITY CODE 404.2.7 DOOR HARDWARE. WHERE | | SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING | | HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. | | HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE | | PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4. | | OPERABLE PARTS. | | 2014 ACCESSIBILITY CODE 309.4 OPERATION. OPERABLE PARTS | | SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE | | TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE | | FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 | | POUNDS MAXIMUM. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-07-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-07-20 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-07-20 |
Time |
11:47 |
Sent To |
|
|
Notes |
2017-07-20 14:36:29 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17070265 | | ADD: 501 S. FLAGLER DR. SUITE : 302 | | CONT: ANDERSON MOORE CONSTRUCTION | | TEL: 561-308-1590 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. JULY 20/ 2017 | | ACTION: DENIED | | | | 1) THE SHEET 004_A.1.1.1. INDICATES A NEW ALCOVE AND | | ENTRY DOOR, THE DOOR IS IDENTIFIED AS 315. THE DOOR | | SCHEDULE FOUND ON 007_A2.0.1 INDICATES THIS DOOR IS A | | 3-0X 8-0 FOOT DOOR. THE INTERIOR SIDE OF THE ALCOVE IS | | DIMENSIONED AS 4 FOOT 6 INCHES WIDE. THE PLANS WHEN | | SCALED SHOW THE 18 INCHES ON THE LATCH SIDE OF THE DOOR | | AS REQUIRED BY THE ACCESSIBILITY CODE. WHEN THE DOOR IS | | MEASURES FOR WIDTH, IT ONLY MEASURES AS A 2 FOOT 71/2 | | INCH DOOR. PLEASE NOTE FOR DOORS IN A MEANS OF EGRESS | | THE DOOR WIDTH WOULD NEED TO BE A 36 INCH WIDE DOOR. | | | | PLEASE REFER TO THE 2014 FBC-B SECTION 1008.1.1 SIZE OF | | DOORS. THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE | | SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND SHALL | | PROVIDE A CLEAR WIDTH OF 32 INCHES (813 MM). CLEAR | | OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE | | MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, | | WITH THE DOOR OPEN 90 DEGREES. | | | | ONCE THE DOOR MEETS THE EGRESS REQUIREMENTS WITH A 4 | | FOOT 6 INCH ALCOVE WIDTH YOU WILL NO LONGER HAVE THE | | REQUIRED 18 INCHES MANEUVERING CLEARANCES ON THE LATCH | | SIDE OF THE DOOR. SEE 2014 ACCESSIBILITY CODE SECTION | | 404.2.4 MANEUVERING CLEARANCES, TABLE 404.2.4.1 AND | | FIGURE 404.2.4.1(A). PLEASE UPDATE THE PLANS. | | | | 2) THE SHEET 004_A.1.1.1. ALSO SHOWS (2) POCKET DOORS, | | DOORS ARE IDENTIFIED AS 313B & 314B. THE DOOR SCHEDULE | | FOUND ON 007_A2.0.1 INDICATES THESE DOORS HARDWARE AS | | GROUP 3, NOTES INDICATE POCKET HARDWARE? PLEASE SHOW | | COMPLIANCE WITH : | | | | 2014 ACCESSIBILITY CODE 404.2.7 DOOR AND GATE HARDWARE. | | WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, | | OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM | | BOTH SIDES. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER | | OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH | | 309.4. OPERABLE PARTS. | | | | 2014 ACCESSIBILITY CODE 309.4 OPERATION. OPERABLE PARTS | | SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE | | TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE | | FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 | | POUNDS (22.2 N) MAXIMUM. | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-08-17 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-17 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-17 |
Time |
07:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-08-01 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-01 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-01 |
Time |
11:30 |
Sent To |
|
|
Notes |
2017-08-01 11:30:20 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. NEW SHEETS SUBMITTED FOR ELECTRICAL, E0-1 AND E2-1, | | NOT SIGNED AND SEALED. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. FBC 107.2.1; FS 471 | | 2. RECEPTACLE CONTROL NOT TO CODE. OFFICES 314 AND 315 | | DO NOT SHOW ANY CONTROL. BREAK AREA DOES NOT MEET | | AMOUNT OF CONTROL REQUIRED. BOTH AREAS REQUIRE A | | MINIMUM OF 50% OF THE OUTLETS CONTROLLED PER ASHRAE | | 90.1:8.4.2. ADDITIONALLY, PLAN CURRENTLY SHOWS 8 | | CIRCUITS BEING CONTROLLED BY A 6 POLE CONTACTOR, WHICH | | WILL OBVIOUSLY NOT WORK. PROVIDE CORRECTIONS. FBC | | C405.7.1, FBC 107.2.1 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-07-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-07-19 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-07-19 |
Time |
12:09 |
Sent To |
|
|
Notes |
2017-07-19 12:14:37 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW COMMENTS: | | | | 1. PROVIDE AUTOMATIC LIGHTING CONTROLS FOR ALL FIXTURES | | PER CODE. IT APPEARS THAT THE HALL IS MISSING CONTROL, | | AND THE CONTROL FOR THE MAIN WORK AREA IS NOT CLEAR. | | CLARIFY AND/OR CORRECT. FBC 107.2.1, C405.2.2 | | 2. PROVIDE RECEPTACLE CONTROL REQUIRED BY FBC C401.2 | | AND ASHREA 90.1: 8.4.2 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-08-01 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-08-01 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-08-01 |
Time |
13:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-07-14 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-07-14 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-08-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-18 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-08-16 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-08-09 |
Time |
|
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-07-31 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-07-21 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-07-12 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-09 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-08-09 |
Time |
10:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-07-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-07-21 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-07-21 |
Time |
17:11 |
Sent To |
|
|
Notes |
2017-07-21 17:13:45 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17070265 | | 7/21/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) M2.1: THE 16X12 MAIN TRUNK IS UNDERSIZED FOR 1600 | | CFMS AT A TYPICAL LOW PRESSURE FRICTION LOSS OF 0.1 | | W.G. | | | | 2) M2.1: PROVIDE THE FLEX DUCT SIZES. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-07-18 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-18 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-18 |
Time |
09:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-18 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2017-08-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-09 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2017-08-09 10:17:16 | SHEET M2.1 NOT DIGITALLY SIGNED AND SEALED- CCOLE- | | 8/9/17 | 2017-08-04 09:03:44 | BUILDING SIGNATURES FOR ARCHITECTURAL SHEETS, MISSING | | ELECTRONIC SIGNATURES: | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, | | REPORTS OR OTHER DOCUMENTS. | | | | AD1.0 | | A.1.1.1 | | A.1.1.2. | | A1.1.3 | | A2.0.1. | | | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2017-07-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-07-21 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2017-07-21 17:14:21 | MECHANICAL AND ELECTRICAL SIGNATURES VERIFIED- CCOLE- | | 7/21/17 | 2017-07-20 14:37:41 | ARCHITECTURAL SHEETS SIGNATURES GOOD. JW 7/20/2017 | 2017-07-18 09:43:37 | 7/18/17 DIG SIG ON PLUMB SHTS. OK/GPJ |
|
|
|