Plan Review Details - Permit 17061109
Plan Review Stops For Permit 17061109
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2017-07-06 Cont ID  
Sent By jleahy Date 2017-07-06 Time 10:40 Rev Time 0.00
Received By jleahy Date 2017-07-06 Time 10:40 Sent To E
Notes
2017-07-06 10:42:27SLAB INCIDENTAL TO THE ELECTRICAL CONTRACTORS WORK
 JLEAHY
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-07-14 Cont ID  
Sent By jleahy Date 2017-07-14 Time 16:28 Rev Time 0.00
Received By jleahy Date 2017-07-14 Time 16:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-07-06 Cont ID  
Sent By jleahy Date 2017-07-06 Time 10:48 Rev Time 0.00
Received By jleahy Date 2017-07-06 Time 10:42 Sent To  
Notes
2017-07-06 10:52:03FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 WIRES FROM METER TO TRANSFER SWITCH AND TO THE PANEL
 FROM TRANSFER SWITCH SHOWS #1, PANEL AND TRANSFER
 SWITCH SHOW 200AMPS
 PLEASE SHOW SIZE OF MAIN IN METER MAIN COMBO.
  
 METER MAIN COMBO NEEDS TO BE THE RINGLESS TYPE OR FPL
 WILL NOT SET METER.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-07-06 Cont ID  
Sent By gjohnson Date 2017-07-06 Time 10:25 Rev Time 0.00
Received By gjohnson Date 2017-07-06 Time 10:25 Sent To  
Notes
2017-07-06 10:26:51GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-14 Cont ID  
Sent By jleahy Date 2017-07-14 Time 16:40 Rev Time 0.00
Received By jleahy Date 2017-07-10 Time 12:54 Sent To  
Notes
2017-07-11 12:54:21RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-06 Cont ID  
Sent By jleahy Date 2017-07-06 Time 10:53 Rev Time 0.00
Received By jleahy Date 2017-06-26 Time 13:38 Sent To  
Notes
2017-06-27 13:38:35ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2017-07-13 Cont ID  
Sent By njwira Date 2017-07-13 Time 11:25 Rev Time 0.00
Received By njwira Date 2017-07-12 Time 09:09 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-06-30 Cont ID  
Sent By njwira Date 2017-06-30 Time 10:07 Rev Time 0.00
Received By njwira Date 2017-06-27 Time 17:03 Sent To  
Notes
2017-06-30 10:08:036/30/17- FAILED
  
 GENERATOR DOESN'T MEET THE REQUIRED 6FT. SIDE SETBACK
  
  
 PLEASE CONTACT
 NATHAN WIRA- ZONING TECHNICIAN
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING
 DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST.
 WEST PALM BEACH, FL 33402
 OFFICE HOURS: M-F 8AM - 5PM
 (561)822-1442
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved