Plan Review Details - Permit 17061098
Plan Review Stops For Permit 17061098
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-08-08 Cont ID  
Sent By cthroop Date 2017-08-08 Time 15:52 Rev Time 0.00
Received By cthroop Date 2017-08-08 Time 15:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-07-06 Cont ID  
Sent By cthroop Date 2017-07-06 Time 10:12 Rev Time 0.00
Received By cthroop Date 2017-07-06 Time 10:10 Sent To  
Notes
2017-07-06 10:14:56BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED SIGN.
 2. PROVIDE STRUCTURAL ATTACHMENT DETAIL FOR PROPOSED
 SIGN, INCLUDE FASTENER SCHEDULE.
 3. DESIGNER TO PRINT NAME AND SIGN PLAN.
  
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-06 Cont ID  
Sent By cthroop Date 2017-07-06 Time 10:12 Rev Time 0.00
Received By cthroop Date 2017-06-23 Time 09:37 Sent To  
Notes
2017-06-26 09:37:49ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2017-08-02 Cont ID  
Sent By ajones Date 2017-08-02 Time 15:07 Rev Time 0.00
Received By ajones Date 2017-08-02 Time 15:07 Sent To  
Notes
2017-08-02 15:08:57PASSED WITH THE PROVISO THAT THE SIGN MUST BE SETBACK 5
 FEET FROM THE PROPERTY LINE.
  
 ANGELLA VANN
 561-822-1441
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2017-06-30 Cont ID  
Sent By ajones Date 2017-06-30 Time 14:37 Rev Time 0.00
Received By ajones Date 2017-06-30 Time 14:37 Sent To  
Notes
2017-06-30 14:39:086/30/17- FAILED. WHAT IS THE CURRENT SETBACK OF THE
 SIGN FOR THE PROPERTY LINES. THE ZONING AND LAND
 DEVELOPMENT REGULATIONS REQUIRES A 5 FOOT SETBACK.
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]
2017-06-26 16:50:34ROUTED TO ANGELA VANN


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved