Plan Review Details - Permit 17061005
Plan Review Stops For Permit 17061005
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2017-12-19 Cont ID  
Sent By ccole Date 2017-12-19 Time 09:16 Rev Time 0.00
Received By ccole Date 2017-12-19 Time 09:16 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-11-16 Cont ID  
Sent By shill Date 2017-11-16 Time 17:50 Rev Time 0.00
Received By shill Date 2017-11-16 Time 17:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-08-10 Cont ID  
Sent By shill Date 2017-08-10 Time 17:40 Rev Time 0.00
Received By shill Date 2017-08-10 Time 17:31 Sent To  
Notes
2017-08-10 17:41:06 
  
  
 *****************************
 INTERNAL USE ONLY
  
 USC-404 TYPE 437 - ALT: NON-RES, NON-HSKPG
 SQUARE FEET -
  
 CONSTRUCTION TYPE:
 UNITS:
 FLOORS:
 BEDROOMS:
 ROOMS:
 SQ FT LIVABLE:
 SQ FT FOOTPRINT:
 SQ FT ROOF:
  
 SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF
 KNOWN):
 SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN):
 XX.XX
 SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN:
 XX.XX
 OCC LOAD: 36
 PROP USE: CAFE
 SPRINKLER SYS? Y
 SPRK REQ'D? Y
 BATHRMS:
  
 BLDG CODE: FL 2014
 OCC CLASS: 5TH ED B
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-26 Cont ID  
Sent By shill Date 2017-06-26 Time 17:42 Rev Time 0.00
Received By shill Date 2017-06-26 Time 17:09 Sent To  
Notes
2017-06-26 17:42:32****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. ALTHOUGH THIS MAY BE CLASSIFIED AS BUSINESS
 OCCUPANCY IF OCCUPANT LOAD IS LESS THAN 50, THE
 OCCUPANT LOAD SHOULD BE AS PER THE USE OF THE SPACE.
 REVISE OCCUPANT LOAD FROM 100 SF PER PERSON TO OCCUPANT
 LOAD FOR RESTAURANT (15 SF, 200 SF KITCHEN), FBC B
 1004.
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2017-12-06 Cont ID  
Sent By jpearson Date 2017-12-06 Time 07:02 Rev Time 0.00
Received By jpearson Date 2017-12-06 Time 07:02 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2017-11-13 Cont ID  
Sent By jpearson Date 2017-11-13 Time 15:55 Rev Time 0.00
Received By jpearson Date 2017-11-13 Time 15:55 Sent To B
Notes
2017-11-13 15:55:24CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. BASED ON NEW SUBMISSION, THE 45 KVA TRANSFORMER IS
 SHOWN OVERLOADED. THE CAPACITY OF A 45KVA TRANSFORMER
 IS 125 AMPS PER PHASE, AND A TOTAL OF 45,000 VA.
 PROVIDE CORRECTION SO THAT TRANSFORMER IS NOT
 OVERLOADED. NEC 110.3, NEC 220
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-08-15 Cont ID  
Sent By jpearson Date 2017-08-15 Time 11:28 Rev Time 0.00
Received By jpearson Date 2017-08-15 Time 11:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-07-05 Cont ID  
Sent By jpearson Date 2017-07-05 Time 08:17 Rev Time 0.00
Received By jpearson Date 2017-07-05 Time 08:17 Sent To  
Notes
2017-07-05 08:51:47CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW COMMENTS:
  
 1. PROVIDE NOTE FOR EXIT AND EMERGENCY LIGHTS TO BE
 CONNECTED AHEAD OF TIMECLOCK CONTROL. NEC 700.12(F)
 2. PROVIDE SERVICE OUTLET FOR CU-1. NEC 210.63
 3. PROVIDE SHOW WINDOW OUTLETS AND CIRCUIT WITH
 LIGHTING CONTROL. NEC 210.62; FBC C405.2.3
 4. LOAD CALCULATION IN PANEL SCHEDULE PROVIDED EXCEEDS
 THE VALUE OF THE TRANSFORMER FEEDING THE UNIT. PROVIDE
 CORRECTION. NEC 110.3
 5. LOAD CALCULATION IN PANEL SCHEDULE PROVIDED SHOWS
 THE SAME RATING FOR ALL REFRIGERATORS AND KITCHEN
 EQUIPMENT. PROVIDE SPEC SHEETS WITH DETAILS OF LOAD FOR
 EACH PIECE OF EQUIPMENT AND REVISE LOAD CALCULATION TO
 REFLECT THE ACTUAL LOADS. NEC 110.3, 215.5, 220
 6. PROVIDE DETAIL OF INTERIOR LIGHTING POWER
 REQUIREMENTS IN RELATION TO THE CONNECTED INTERIOR
 LIGHTING PROPOSED TO COMPLY WITH CODE. FBC C405.5
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2017-10-30 Cont ID  
Sent By scaldero Date 2017-10-30 Time 14:32 Rev Time 0.00
Received By scaldero Date 2017-10-30 Time 14:25 Sent To  
Notes
2017-10-30 14:32:09PERMIT # 17061005
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 APPROVED PROVISO:
  
 1) A SEPERATE PERMIT IS REQUIRED FOR THE INTALLATION OF
 THE VENTLESS COOKING HOOD SYSTEM. INSTALLATION SHALL
 COMPLY WITH ALL APPLICABLE NFPA CODES AND STANDARDS,
 INCLUDIN, BUT NOT
 LIMITED TO INTERCONNECTION WITH THE FIRE ALARM SYSTEM,
 IF APPLICABLE.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 644-7326
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-08-16 Cont ID  
Sent By scaldero Date 2017-08-16 Time 09:47 Rev Time 0.00
Received By scaldero Date 2017-08-16 Time 09:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-06-26 Cont ID  
Sent By scaldero Date 2017-06-26 Time 15:02 Rev Time 0.00
Received By scaldero Date 2017-06-26 Time 14:47 Sent To  
Notes
2017-06-26 15:02:23PERMIT # 17061005
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FAILED COMMENTS:
  
 1) SHEET CVR: ADDRESS IS LISTED AS BOTH 511 AND 517 N.
 OLIVE AVE. PLEASE ENSURE THAT ONLY THE CORRECT ADDRESS
 IS LISTED ON THE PLANS.
  
 2) SHEET ALS 1.1: OCCUPANCY LOAD IS LISTED AS "9
 PERSONS", HOWEVER THE LAYOUT SHOWS SEATING FOR 17
 PERSONS.
 PLEASE REVISE OCCUPANCY LOAD AND/OR SEATING PLAN TO
 SHOW ACCURATE OCCUPANCY. WHERE POSSIBLE, PLEASE BREAK
 DOWN THE OCCUPANCY LOAD BY DINIING/SEATING AREA,
 QUEUEING, AND KITCHEN LOADS.
  
 3) SHEET ALS 1.1: THE DRAWINGS SHOW A DOOR IN REAR OF
 THE SPACE, PLEASE ADVISE IF THAT IS A 2ND MEANS OF
 EGREES (EMERGENCY EXIT), IF SO, IT NEEDS TO BE
 IDENTIFIED ACCORDINGLY.
 IF IT IS NOT A MEANS OF EGRESS, ALL EXTERIOR DOORS NOT
 FUNCTIONING AS EXITS SHALL BE PERMANENTLY MARKED AND
 CLEARLY INDICATED AS, "NOT AN EXIT."
  
 4) SHEET A1.4: PLEASE PROVIDE MANUFACTURER'S SPECS FOR
 EQUIPMENT ITEM "8" - THE ALL IN ONE VENTLESS COOKING
 SYSTEM.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 644-7326
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2017-12-19 Time   Rev Time 0.00
Received By lmarchan Date 2017-12-14 Time 13:56 Sent To  
Notes
2017-12-15 13:56:15RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2017-12-13 Time   Rev Time 0.00
Received By lmarchan Date 2017-12-04 Time 15:21 Sent To  
Notes
2017-12-05 15:21:16RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-11-16 Cont ID  
Sent By shill Date 2017-11-16 Time 17:50 Rev Time 0.00
Received By shill Date 2017-10-24 Time 13:29 Sent To  
Notes
2017-10-26 13:29:38B20

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-08-22 Cont ID  
Sent By gjohnson Date 2017-08-22 Time 11:05 Rev Time 0.00
Received By gjohnson Date 2017-08-08 Time 13:14 Sent To  
Notes
2017-08-09 13:14:17B20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-06 Cont ID  
Sent By gjohnson Date 2017-07-06 Time 16:16 Rev Time 0.00
Received By gjohnson Date 2017-06-22 Time 16:02 Sent To  
Notes
2017-06-23 16:02:09B19

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2017-12-19 Cont ID  
Sent By ccole Date 2017-12-19 Time 09:16 Rev Time 0.00
Received By ccole Date 2017-12-19 Time 09:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2017-12-13 Cont ID  
Sent By ccole Date 2017-12-13 Time 10:43 Rev Time 0.00
Received By ccole Date 2017-12-13 Time 10:43 Sent To I
Notes
2017-12-13 11:03:564TH REVIEW FBC-2014 MECHANICAL
 PERMIT #17061005
 12/13/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 MANY OF THE PREVIOUS COMMENTS STILL EXIST. PER
 TELEPHONE CONVERSATION WITH MIGUEL OF GLIDDEN-SPINA THE
 CIMMENTS LISTED BELOW ARE UNDERSTOOD AND WILL BE
 ADDRESSED ON THE NEXT PLAN SUBMISSION.
  
 1) SHEETS: A1.1 & A1.3 STILL SHOW THE AC CLOSET DOOR
 OPENING INTO THE KITCHEN.
  
 2) SHEET A2 IS STILL INDICATING THE AC CLOSET DOOR TO
 BE WOOD AND NOT NON-COMBUSTIBLE.
  
 3) REQUESTED AC COOLING AND HEATING CALCULATIONS NIT
 SUBMITTED.
  
 4) UL 197 LISTING AND LABELING FOR THE ELECTRIC COOKING
 APPLIANCE NOT VERIFIED ON THE VENTLESS HOOD SUBMITTAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2017-11-02 Cont ID  
Sent By ccole Date 2017-11-02 Time 08:27 Rev Time 0.00
Received By ccole Date 2017-11-02 Time 07:20 Sent To  
Notes
2017-11-02 08:40:561ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17061005
 11/2/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 THE COMMENTS FROM THE 2ND REVIEW WERE NOT ADDRESSED AND
 STILL EXIST. THOSE COMMENTS ARE PRINTED BELOW AN
 ADDITIONAL REVIEW COMMENTS BASED ON THE RESUBMITTED
 PLANS.
  
 1) THE REVISED M2.1 PLAN SHOWS THE AC CLOSET LOUVERED
 DOOR RELOCATED TO THE WALL BETWEEN THE CLOSET AND THE
 KITCHEN. PLEASE REFER TOTABLE 403.3 FOOTNOTE B. AND
 SECTION 403.2.1(3) WHICH PROHIBITS AIR FROM THE KITCHEN
 TO BE RECIRCULATED TO THE DINING ROOM. ALL AIR TO THE
 KITCHEN SHALL BE EXHAUSTED.
  
 2) SHEET A2.0: AS PREVIOUSLY NOTED IN THE 1ST REVIEW,
 THE AC CLOSET DOOR SHALL BE NON-COMBUSTIBLE, HOWEVER
 THE SCHEDULE IS STILL INDICATING A WOOD DOOR.
  
  
 2ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17061005
 8/17/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS 400
 CFMS OF FRESH AIR IS REQUIRED AS MAKEUP AIR FOR THE
 VENTLESS HOOD, HOWEVER NO AIR IS BEING PROVIDED PER THE
 AC EQUIPMENT SCHEDULE AND THE VENTILATION CALCULATIONS.
 PLEASE NOTE THAT THE SPECS ARE ALSO RECOMMENDING 400
 CFMS OF FRESH AIR OUTSIDE OF THE COOKING AREA OR THE
 DINING AREA, HOWEVER THE SCHEDULE INDICATES ONLY 325
  
 CFMS OF AIR BEING PROVIDED THERE- SECTION 507.2.1.
  
 2) PROVIDE DOCUMENTATION THAT THE COOKING APPLIANCE IS
 LISTED AND LABELED IN ACCORDANCE WITH UL 197- SECTION
 917.1.
  
 3) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW AC SYSTEMS- SECTION C403.2.1 FBC-14 ENERGY
 CONSERVATION.
  
 4) PLEASE PLACE A NOTE ON THE PLANS INDICATING A
 SEPARATE PERMIT IS REQUIRED FOR INSTALLATION OF THE
 VENTLESS HOOD AND INTEGRAL FIRE SUPPRESSION SYSTEM-
 SECTION 107.1 WPB AMENDMENTS TO THE FBC.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-08-17 Cont ID  
Sent By ccole Date 2017-08-17 Time 10:15 Rev Time 0.00
Received By ccole Date 2017-08-17 Time 10:01 Sent To  
Notes
2017-08-17 10:20:032ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17061005
 8/17/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS 400
 CFMS OF FRESH AIR IS REQUIRED AS MAKEUP AIR FOR THE
 VENTLESS HOOD, HOWEVER NO AIR IS BEING PROVIDED PER THE
 AC EQUIPMENT SCHEDULE AND THE VENTILATION CALCULATIONS.
 PLEASE NOTE THAT THE SPECS ARE ALSO RECOMMENDING 400
 CFMS OF FRESH AIR OUTSIDE OF THE COOKING AREA OR THE
 DINING AREA, HOWEVER THE SCHEDULE INDICATES ONLY 325
  
 CFMS OF AIR BEING PROVIDED THERE- SECTION 507.2.1.
  
 2) PROVIDE DOCUMENTATION THAT THE COOKING APPLIANCE IS
 LISTED AND LABELED IN ACCORDANCE WITH UL 197- SECTION
 917.1.
  
 3) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW AC SYSTEMS- SECTION C403.2.1 FBC-14 ENERGY
 CONSERVATION.
  
 4) PLEASE PLACE A NOTE ON THE PLANS INDICATING A
 SEPARATE PERMIT IS REQUIRED FOR INSTALLATION OF THE
 VENTLESS HOOD AND INTEGRAL FIRE SUPPRESSION SYSTEM-
 SECTION 107.1 WPB AMENDMENTS TO THE FBC.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-07-03 Cont ID  
Sent By ccole Date 2017-07-03 Time 14:34 Rev Time 0.00
Received By ccole Date 2017-07-03 Time 14:34 Sent To  
Notes
2017-07-03 14:53:181ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17061005
 7/3/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SUBMIT MANUFACTURER'S SPECIFCATIONS FOR THE VENTLESS
 COOKING SYSTEM- SECTION 917.1.
  
 2) EXHAUST VENTILATION AT A RATE OF .070 CFMS PER
 SQ.FT. IS REQUIRED FOR THE KITCHEN PER TABLE 403.3, AND
 RECIRCULATION OF AIR FROM THE SPACE IS PROHIBITED PER
 FOOTNOTE B. THE CURRENT PLAN IS NOT IN COMPLIANCE-
 PLEASE CORRECT.
  
 3) M0.1: THE OUTSIDE AIR CALCULATIONS FOR "OFFICES" ARE
 NOT APPLICABLE TO THE PROPOSED OCCUPANCY WHICH IS CAFE
 OR DINING/KITCHEN.
  
 4) M2.1: A LOUVERED AC CLOSET DOOR IS INDICATED,
 HOWEVER THE DOOR SCHEDULE ON A2 INDICATES A SOLID WOOD
 DOOR- SEE SECTION C403.2.7.2 FBC-14 ENERGY COMPLIANCE
 AND SECTION 602.2.1- A NON-COMBUSTIBLE DOOR IS
 REQUIRED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-11-04 Cont ID  
Sent By gjohnson Date 2017-11-04 Time 08:20 Rev Time 0.00
Received By gjohnson Date 2017-11-03 Time 13:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-08-22 Cont ID  
Sent By gjohnson Date 2017-08-22 Time 11:04 Rev Time 0.00
Received By gjohnson Date 2017-08-22 Time 10:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-07-06 Cont ID  
Sent By gjohnson Date 2017-07-06 Time 15:46 Rev Time 0.00
Received By gjohnson Date 2017-07-06 Time 14:25 Sent To  
Notes
2017-07-06 16:16:301ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. A VENT IS REQUIRED ON THE FLOW CONTROL AT THE INLET
 OF GREASE INTERCEPTOR PER MANUFACTURE INSTALLATION
 GUIDE.
  
 2. A VENT IS REQUIRED ON THE OUTLET OF THE GREASE
 INTERCEPTOR PER MANUFACTURE INSTALLATION GUIDE AND FBC
 PL 901.2- 901.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  