Plan Review Stops For Permit 17061005 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-12-19 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-12-19 |
Time |
09:16 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-11-16 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-11-16 |
Time |
17:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-08-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-08-10 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-08-10 |
Time |
17:31 |
Sent To |
|
|
Notes |
2017-08-10 17:41:06 | | | | | | | ***************************** | | INTERNAL USE ONLY | | | | USC-404 TYPE 437 - ALT: NON-RES, NON-HSKPG | | SQUARE FEET - | | | | CONSTRUCTION TYPE: | | UNITS: | | FLOORS: | | BEDROOMS: | | ROOMS: | | SQ FT LIVABLE: | | SQ FT FOOTPRINT: | | SQ FT ROOF: | | | | SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF | | KNOWN): | | SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN): | | XX.XX | | SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN: | | XX.XX | | OCC LOAD: 36 | | PROP USE: CAFE | | SPRINKLER SYS? Y | | SPRK REQ'D? Y | | BATHRMS: | | | | BLDG CODE: FL 2014 | | OCC CLASS: 5TH ED B | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-06-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-06-26 |
Time |
17:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-06-26 |
Time |
17:09 |
Sent To |
|
|
Notes |
2017-06-26 17:42:32 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. ALTHOUGH THIS MAY BE CLASSIFIED AS BUSINESS | | OCCUPANCY IF OCCUPANT LOAD IS LESS THAN 50, THE | | OCCUPANT LOAD SHOULD BE AS PER THE USE OF THE SPACE. | | REVISE OCCUPANT LOAD FROM 100 SF PER PERSON TO OCCUPANT | | LOAD FOR RESTAURANT (15 SF, 200 SF KITCHEN), FBC B | | 1004. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2017-12-06 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-12-06 |
Time |
07:02 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-12-06 |
Time |
07:02 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-13 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-13 |
Time |
15:55 |
Sent To |
B |
|
Notes |
2017-11-13 15:55:24 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. BASED ON NEW SUBMISSION, THE 45 KVA TRANSFORMER IS | | SHOWN OVERLOADED. THE CAPACITY OF A 45KVA TRANSFORMER | | IS 125 AMPS PER PHASE, AND A TOTAL OF 45,000 VA. | | PROVIDE CORRECTION SO THAT TRANSFORMER IS NOT | | OVERLOADED. NEC 110.3, NEC 220 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-08-15 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-15 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-15 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-07-05 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-07-05 |
Time |
08:17 |
Sent To |
|
|
Notes |
2017-07-05 08:51:47 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW COMMENTS: | | | | 1. PROVIDE NOTE FOR EXIT AND EMERGENCY LIGHTS TO BE | | CONNECTED AHEAD OF TIMECLOCK CONTROL. NEC 700.12(F) | | 2. PROVIDE SERVICE OUTLET FOR CU-1. NEC 210.63 | | 3. PROVIDE SHOW WINDOW OUTLETS AND CIRCUIT WITH | | LIGHTING CONTROL. NEC 210.62; FBC C405.2.3 | | 4. LOAD CALCULATION IN PANEL SCHEDULE PROVIDED EXCEEDS | | THE VALUE OF THE TRANSFORMER FEEDING THE UNIT. PROVIDE | | CORRECTION. NEC 110.3 | | 5. LOAD CALCULATION IN PANEL SCHEDULE PROVIDED SHOWS | | THE SAME RATING FOR ALL REFRIGERATORS AND KITCHEN | | EQUIPMENT. PROVIDE SPEC SHEETS WITH DETAILS OF LOAD FOR | | EACH PIECE OF EQUIPMENT AND REVISE LOAD CALCULATION TO | | REFLECT THE ACTUAL LOADS. NEC 110.3, 215.5, 220 | | 6. PROVIDE DETAIL OF INTERIOR LIGHTING POWER | | REQUIREMENTS IN RELATION TO THE CONNECTED INTERIOR | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC C405.5 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-10-30 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2017-10-30 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2017-10-30 |
Time |
14:25 |
Sent To |
|
|
Notes |
2017-10-30 14:32:09 | PERMIT # 17061005 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | APPROVED PROVISO: | | | | 1) A SEPERATE PERMIT IS REQUIRED FOR THE INTALLATION OF | | THE VENTLESS COOKING HOOD SYSTEM. INSTALLATION SHALL | | COMPLY WITH ALL APPLICABLE NFPA CODES AND STANDARDS, | | INCLUDIN, BUT NOT | | LIMITED TO INTERCONNECTION WITH THE FIRE ALARM SYSTEM, | | IF APPLICABLE. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 644-7326 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-08-16 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2017-08-16 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2017-08-16 |
Time |
09:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-06-26 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2017-06-26 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2017-06-26 |
Time |
14:47 |
Sent To |
|
|
Notes |
2017-06-26 15:02:23 | PERMIT # 17061005 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | FAILED COMMENTS: | | | | 1) SHEET CVR: ADDRESS IS LISTED AS BOTH 511 AND 517 N. | | OLIVE AVE. PLEASE ENSURE THAT ONLY THE CORRECT ADDRESS | | IS LISTED ON THE PLANS. | | | | 2) SHEET ALS 1.1: OCCUPANCY LOAD IS LISTED AS "9 | | PERSONS", HOWEVER THE LAYOUT SHOWS SEATING FOR 17 | | PERSONS. | | PLEASE REVISE OCCUPANCY LOAD AND/OR SEATING PLAN TO | | SHOW ACCURATE OCCUPANCY. WHERE POSSIBLE, PLEASE BREAK | | DOWN THE OCCUPANCY LOAD BY DINIING/SEATING AREA, | | QUEUEING, AND KITCHEN LOADS. | | | | 3) SHEET ALS 1.1: THE DRAWINGS SHOW A DOOR IN REAR OF | | THE SPACE, PLEASE ADVISE IF THAT IS A 2ND MEANS OF | | EGREES (EMERGENCY EXIT), IF SO, IT NEEDS TO BE | | IDENTIFIED ACCORDINGLY. | | IF IT IS NOT A MEANS OF EGRESS, ALL EXTERIOR DOORS NOT | | FUNCTIONING AS EXITS SHALL BE PERMANENTLY MARKED AND | | CLEARLY INDICATED AS, "NOT AN EXIT." | | | | 4) SHEET A1.4: PLEASE PROVIDE MANUFACTURER'S SPECS FOR | | EQUIPMENT ITEM "8" - THE ALL IN ONE VENTLESS COOKING | | SYSTEM. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 644-7326 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-12-19 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-12-14 |
Time |
13:56 |
Sent To |
|
|
Notes |
2017-12-15 13:56:15 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-12-13 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-12-04 |
Time |
15:21 |
Sent To |
|
|
Notes |
2017-12-05 15:21:16 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-11-16 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-10-24 |
Time |
13:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-08-22 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-08-08 |
Time |
13:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-07-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-06 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-22 |
Time |
16:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-12-19 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-12-19 |
Time |
09:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2017-12-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-12-13 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-12-13 |
Time |
10:43 |
Sent To |
I |
|
Notes |
2017-12-13 11:03:56 | 4TH REVIEW FBC-2014 MECHANICAL | | PERMIT #17061005 | | 12/13/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | MANY OF THE PREVIOUS COMMENTS STILL EXIST. PER | | TELEPHONE CONVERSATION WITH MIGUEL OF GLIDDEN-SPINA THE | | CIMMENTS LISTED BELOW ARE UNDERSTOOD AND WILL BE | | ADDRESSED ON THE NEXT PLAN SUBMISSION. | | | | 1) SHEETS: A1.1 & A1.3 STILL SHOW THE AC CLOSET DOOR | | OPENING INTO THE KITCHEN. | | | | 2) SHEET A2 IS STILL INDICATING THE AC CLOSET DOOR TO | | BE WOOD AND NOT NON-COMBUSTIBLE. | | | | 3) REQUESTED AC COOLING AND HEATING CALCULATIONS NIT | | SUBMITTED. | | | | 4) UL 197 LISTING AND LABELING FOR THE ELECTRIC COOKING | | APPLIANCE NOT VERIFIED ON THE VENTLESS HOOD SUBMITTAL. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-11-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-11-02 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-11-02 |
Time |
07:20 |
Sent To |
|
|
Notes |
2017-11-02 08:40:56 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17061005 | | 11/2/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | THE COMMENTS FROM THE 2ND REVIEW WERE NOT ADDRESSED AND | | STILL EXIST. THOSE COMMENTS ARE PRINTED BELOW AN | | ADDITIONAL REVIEW COMMENTS BASED ON THE RESUBMITTED | | PLANS. | | | | 1) THE REVISED M2.1 PLAN SHOWS THE AC CLOSET LOUVERED | | DOOR RELOCATED TO THE WALL BETWEEN THE CLOSET AND THE | | KITCHEN. PLEASE REFER TOTABLE 403.3 FOOTNOTE B. AND | | SECTION 403.2.1(3) WHICH PROHIBITS AIR FROM THE KITCHEN | | TO BE RECIRCULATED TO THE DINING ROOM. ALL AIR TO THE | | KITCHEN SHALL BE EXHAUSTED. | | | | 2) SHEET A2.0: AS PREVIOUSLY NOTED IN THE 1ST REVIEW, | | THE AC CLOSET DOOR SHALL BE NON-COMBUSTIBLE, HOWEVER | | THE SCHEDULE IS STILL INDICATING A WOOD DOOR. | | | | | | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #17061005 | | 8/17/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS 400 | | CFMS OF FRESH AIR IS REQUIRED AS MAKEUP AIR FOR THE | | VENTLESS HOOD, HOWEVER NO AIR IS BEING PROVIDED PER THE | | AC EQUIPMENT SCHEDULE AND THE VENTILATION CALCULATIONS. | | PLEASE NOTE THAT THE SPECS ARE ALSO RECOMMENDING 400 | | CFMS OF FRESH AIR OUTSIDE OF THE COOKING AREA OR THE | | DINING AREA, HOWEVER THE SCHEDULE INDICATES ONLY 325 | | | | CFMS OF AIR BEING PROVIDED THERE- SECTION 507.2.1. | | | | 2) PROVIDE DOCUMENTATION THAT THE COOKING APPLIANCE IS | | LISTED AND LABELED IN ACCORDANCE WITH UL 197- SECTION | | 917.1. | | | | 3) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | NEW AC SYSTEMS- SECTION C403.2.1 FBC-14 ENERGY | | CONSERVATION. | | | | 4) PLEASE PLACE A NOTE ON THE PLANS INDICATING A | | SEPARATE PERMIT IS REQUIRED FOR INSTALLATION OF THE | | VENTLESS HOOD AND INTEGRAL FIRE SUPPRESSION SYSTEM- | | SECTION 107.1 WPB AMENDMENTS TO THE FBC. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-08-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-17 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-08-17 |
Time |
10:01 |
Sent To |
|
|
Notes |
2017-08-17 10:20:03 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #17061005 | | 8/17/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS 400 | | CFMS OF FRESH AIR IS REQUIRED AS MAKEUP AIR FOR THE | | VENTLESS HOOD, HOWEVER NO AIR IS BEING PROVIDED PER THE | | AC EQUIPMENT SCHEDULE AND THE VENTILATION CALCULATIONS. | | PLEASE NOTE THAT THE SPECS ARE ALSO RECOMMENDING 400 | | CFMS OF FRESH AIR OUTSIDE OF THE COOKING AREA OR THE | | DINING AREA, HOWEVER THE SCHEDULE INDICATES ONLY 325 | | | | CFMS OF AIR BEING PROVIDED THERE- SECTION 507.2.1. | | | | 2) PROVIDE DOCUMENTATION THAT THE COOKING APPLIANCE IS | | LISTED AND LABELED IN ACCORDANCE WITH UL 197- SECTION | | 917.1. | | | | 3) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | NEW AC SYSTEMS- SECTION C403.2.1 FBC-14 ENERGY | | CONSERVATION. | | | | 4) PLEASE PLACE A NOTE ON THE PLANS INDICATING A | | SEPARATE PERMIT IS REQUIRED FOR INSTALLATION OF THE | | VENTLESS HOOD AND INTEGRAL FIRE SUPPRESSION SYSTEM- | | SECTION 107.1 WPB AMENDMENTS TO THE FBC. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-07-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-07-03 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-07-03 |
Time |
14:34 |
Sent To |
|
|
Notes |
2017-07-03 14:53:18 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17061005 | | 7/3/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SUBMIT MANUFACTURER'S SPECIFCATIONS FOR THE VENTLESS | | COOKING SYSTEM- SECTION 917.1. | | | | 2) EXHAUST VENTILATION AT A RATE OF .070 CFMS PER | | SQ.FT. IS REQUIRED FOR THE KITCHEN PER TABLE 403.3, AND | | RECIRCULATION OF AIR FROM THE SPACE IS PROHIBITED PER | | FOOTNOTE B. THE CURRENT PLAN IS NOT IN COMPLIANCE- | | PLEASE CORRECT. | | | | 3) M0.1: THE OUTSIDE AIR CALCULATIONS FOR "OFFICES" ARE | | NOT APPLICABLE TO THE PROPOSED OCCUPANCY WHICH IS CAFE | | OR DINING/KITCHEN. | | | | 4) M2.1: A LOUVERED AC CLOSET DOOR IS INDICATED, | | HOWEVER THE DOOR SCHEDULE ON A2 INDICATES A SOLID WOOD | | DOOR- SEE SECTION C403.2.7.2 FBC-14 ENERGY COMPLIANCE | | AND SECTION 602.2.1- A NON-COMBUSTIBLE DOOR IS | | REQUIRED. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-11-04 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-11-04 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-11-03 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-08-22 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-08-22 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-07-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-06 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-06 |
Time |
14:25 |
Sent To |
|
|
Notes |
2017-07-06 16:16:30 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. A VENT IS REQUIRED ON THE FLOW CONTROL AT THE INLET | | OF GREASE INTERCEPTOR PER MANUFACTURE INSTALLATION | | GUIDE. | | | | 2. A VENT IS REQUIRED ON THE OUTLET OF THE GREASE | | INTERCEPTOR PER MANUFACTURE INSTALLATION GUIDE AND FBC | | PL 901.2- 901.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|