Plan Review Stops For Permit 17060927 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-22 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-22 |
Time |
09:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-19 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-15 |
Time |
11:25 |
Sent To |
M |
|
Notes |
2017-09-19 11:27:19 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | 2. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS OR | | SELECT TO DEFER THESE SUBMITALS AT A LATER DATE. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | SUBMITTALS. | | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-07-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-07-12 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-07-12 |
Time |
11:56 |
Sent To |
|
|
Notes |
2017-07-12 15:33:56 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE AN ENERGY SUBMITTAL. R-VALUE FOR ATTIC BATT | | INSULATION AND RIGID FLOOR INSULATION NOT IDENTIFIED ON | | PLAN. | | 2. PROVIDE PRODUCT APPROVALS REVIEWED AND APPROVED BY | | DESIGNER OF RECORD. | | 3. ROOFING PERMIT WILL BE REQUIRED. | | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | STORIES. ENERGY | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | - OR - | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | (MANDATORY). | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | FOUND IN APPENDIX C. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | SUBMITTALS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-09-11 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-11 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-11 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-07-11 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-07-11 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-07-11 |
Time |
10:41 |
Sent To |
|
|
Notes |
2017-07-11 11:05:06 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW COMMENTS: | | | | 1. RISER DIAGRAM SHOWS 3/0 AL CONDUCTORS IN SERVICE | | RISER. 3/0 AL IS NOT RATED FOR 200 AMPS. PROVIDE | | CORRECTION. NEC 310.15; FBC RE3603.1 | | 2. NOTE 1 STATES THAT RECEPTACLES SHALL BE TAMPER | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE4002.14 | | 3. NOTE 13 ALSO REFERENCES THE WRONG CODE SECTION FOR | | LIGHTING IN CLOTHES CLOSETS. PROVIDE CORRECTION. NEC | | 410.16; FBC RE4003.12 | | 4. REMOVE ANY NOTES NOT APPLICABLE TO THIS PROJECT. IF | | THERE WILL BE A POOL, PROVIDE NOTE THAT STATES THE POOL | | WILL BE UNDER SEPARATE PERMIT. FBC 107.2.1 | | 5. CIRCUITS 25, 27, 22, 24, AND 26 SHOULD BE AFCI | | PROTECTED CIRCUITS BASED ON THE DESCRIPTION. PROVIDE | | CORRECTION. NEC 210.12; FBC RE3902.12 | | 6. PROVIDE COMPLIANCE WITH LIGHTING ENERGY | | CONSERVATION: "A MINIMUM OF 75 PERCENT OF THE LAMPS IN | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE | | HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF THE | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN | | ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. FBC EC | | R404.1 | | 7. LIGHTING IN BATHTUB OR SHOWER AREAS AND PORCH AREA | | SHALL BE SUITABLE FOR DAMP LOCATIONS. THESE AREAS | | CURRENTLY SHOW A STANDARD RECESS LIGHT. PROVIDE | | CORRECTION. NEC 410.10(A), FBC RE4003.11 | | 8. LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS AND | | PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE | | PERMITTED IN CLOTHES CLOSETS. THE MASTER CLOSET SHOWS A | | STANDARD RECESS LIGHT. PROVIDE CORRECTION. NEC | | 410.16(B), FBC RE4003.12 | | 9. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | FROM A RECEPTACLE OUTLET. NEC 210.52; FBC RE3901.2.1 | | 10. PROVIDE OUTLET ON REAR OF HOUSE. FOR A ONE FAMILY | | DWELLING AND EACH UNIT OF A TWO-FAMILY DWELLING THAT IS | | AT GRADE LEVEL, AT LEAST ONE RECEPTACLE OUTLET READILY | | ACCESSIBLE FROM GRADE AND NOT MORE THAN 2.0 M (6.5 FT) | | ABOVE GRADE LEVEL SHALL BE INSTALLED AT THE FRONT AND | | BACK OF THE DWELLING. NEC 210.52(E)(1) FBC RE3901.7 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-08-25 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-08-25 |
Time |
14:02 |
Sent To |
B |
|
Notes |
2017-08-25 14:04:17 | 8/25/2017 - REVISED PLANS HAVE NO IMPACT TO HISTORIC | | PROVISIONS. DLE |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2017-06-29 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-06-29 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-06-29 |
Time |
15:15 |
Sent To |
B |
|
Notes |
2017-06-30 07:54:11 | 6/29/2017 - NO PRODUCT APPROVALS INCLUDED WITH PERMIT. | | DLE | 2017-06-29 15:18:08 | 6/29/2017 - MET WITH ARCHITECT TO DISCUSS PROPOSED | | RENOVATION TO LOCALLY DESIGNATED HISTORIC PROPERTY. ALL | | PROPOSED WORK MEETS DESIGN GUIDELINES, EXCEPT FOR | | MENTION OF VINYL LATTICE TO SHIELD CRAWLSPACE (A1.0, | | A2.1, A3.0 - PART R23). PLEASE REVISE TO WOOD LATTICE | | OR METAL SCREEN. DLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-09-19 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-08-17 |
Time |
12:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-07-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-07-19 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-06-20 |
Time |
14:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-09-19 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-09-19 |
Time |
13:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-07-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-07-19 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-07-19 |
Time |
11:01 |
Sent To |
|
|
Notes |
2017-07-19 13:36:13 | PLAN DENIED | | 1) CAN'T HAVE RETURN AIR IN KITCHEN. REFER TO | | SECTION M1602.2 PROHIBITED SOURCES #4 | | 2014 RESIDENTIAL CODE | | 2) MASTER BEDROOM REFER TO SECTION M1602.4 | | BALANCED RETURN AIR 2014 RESIDENTIAL CODE | | 3) HEAT LODE REQUIRED, REFER TO SECTION M1401.3 | | SIZING 2014 RESIDENTIAL CODE. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-09-14 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-09-14 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-09-14 |
Time |
14:52 |
Sent To |
|
|
Notes |
2017-09-14 15:15:04 | BACKFLOW REQUIRES SEPERATE PERMIT |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-07-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-11 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-11 |
Time |
13:31 |
Sent To |
|
|
Notes |
2017-07-11 14:06:14 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. PLEASE PUT A NOTE ON THE PLAN THAT A SEPARATE PERMIT | | IS REQUIRED FOR THE BACKFLOW. PER WPB AMEND TO FBC | | 107.2.1 | | | | 2. SHT P2.1 DETAIL #6 THE BACK FLOW IS REQUIRED TO BE | | LEAD FREE THE WATTS MODEL #909 THAT YOU REFERENCE ON | | DETAIL IS NOT LEAD FREE MANUFACTURE SPECS SHOWING | | DEVICE IS LEAD FREE WILL BE REQUIRED WITH SEPARATE | | PERMIT APPLICATION SO THIS DETAIL DOES NOT NEED TO BE | | ON THE MASTER SET OF PLANS. PER FBC RES P2905.2.1 | | | | 3. PLEASE SHOW WATER HEATER PAN DRAIN TERMINATION/ PER | | FBC RES P2801.5.2 | | | | 4. SHOW T AND P VALVE DISCHARGE PIPING. TO COMPLY WITH | | FBC RES P2803.6.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-22 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-22 |
Time |
09:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-19 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-15 |
Time |
16:16 |
Sent To |
|
|
Notes |
2017-09-19 11:30:15 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | 2. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM COMPONENTS | | OR REMOVE ROOFING FROM SCOPE OF WORK AND SUBMIT STAND | | ALONE ROOFING PERMIT PRIOR TO ROOFING INSTALLATION. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-08-25 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-08-25 |
Time |
14:03 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-06-29 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-06-29 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-06-29 |
Time |
15:18 |
Sent To |
B |
|
Notes |
|
|