Plan Review Details - Permit 17060873
Plan Review Stops For Permit 17060873
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-09-01 Cont ID  
Sent By cthroop Date 2017-09-01 Time 10:59 Rev Time 0.00
Received By cthroop Date 2017-09-01 Time 10:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-07-10 Cont ID  
Sent By cthroop Date 2017-07-10 Time 08:41 Rev Time 0.00
Received By cthroop Date 2017-07-10 Time 08:39 Sent To Z
Notes
2017-07-10 08:46:51BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THERE IS A DESCREPENCY OF FASTENER REQUIREMENTS
 BETWEEN THE PLAN PAGE AND ENGINEER'S DESIGN. PLAN PAGE
 SPECIFIES #12 CONCRETE SCREWS, ENGINEERED DESIGN
 SPECIFIES EITHER #10 SHEET METAL SCREWS FOR METAL WALL
 OR 3/8" EXPANSION ANCHORS FOR CONRETE WALL. PLEASE
 CLARIFY.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-08-31 Cont ID  
Sent By jleahy Date 2017-08-31 Time 11:54 Rev Time 0.00
Received By jleahy Date 2017-08-31 Time 11:54 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-06-30 Cont ID  
Sent By jleahy Date 2017-06-30 Time 16:23 Rev Time 0.00
Received By jleahy Date 2017-06-30 Time 16:23 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-09-01 Cont ID  
Sent By cthroop Date 2017-09-01 Time 10:59 Rev Time 0.00
Received By cthroop Date 2017-08-17 Time 10:06 Sent To  
Notes
2017-08-18 10:07:08RESUB ROUTD TO ESCHNEIDER VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-17 Cont ID  
Sent By eschneid Date 2017-07-17 Time 16:14 Rev Time 0.00
Received By eschneid Date 2017-06-20 Time 11:25 Sent To  
Notes
2017-06-21 11:25:14ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2017-08-30 Cont ID  
Sent By eschneid Date 2017-08-30 Time 14:33 Rev Time 0.25
Received By eschneid Date 2017-08-30 Time 14:28 Sent To E
Notes
2017-08-21 10:18:29ROUTED TO ERIC SCHNEIDER

Review Stop Z ZONING
Rev No 1 Status F Date 2017-07-17 Cont ID  
Sent By eschneid Date 2017-07-17 Time 15:55 Rev Time 0.25
Received By eschneid Date 2017-07-17 Time 15:55 Sent To  
Notes
2017-07-17 16:14:13FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES.
  
 1) CITYPLACE OFFICE TOWER MANAGEMENT APPROVAL IS
 REQUIRED ON THE PLANS.
  
 2) THE TEXT AND ELEVATION DRAWING APPROVED AS PART OF
 THE CITYPLACE MASTER SIGN PLAN PERMIT THE MEDIUM TENANT
 IDENTIFICATION SIGN AT THE TOP OF THE 5TH FLOOR ON THE
 EAST BUILDING ELEVATION. THE SUBMITTED EAST ELEVATION
 PLAN SHOWS THE SIGN AT THE TOP OF THE 6TH FLOOR.
 ADDITIONALLY, THE ELEVATION DRAWING INCLUDED IN THE
 CITYPLACE MASTER SIGN PLAN SHOW THE APPROVED SIGN
 LOCATION FURTHER TO THE NORTH ON THE BUILDING (IN LINE
 WITH THE SECOND COLUMN OF WINDOWS IN LINE WITH THE
 EXISTING INTECH SIGN).
  
 3) THE SIGN SIZE COMPLIES WITH CITYPLACE MASTER SIGN
 PLAN.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
2017-06-29 14:27:25ROUTED TO ERIC SCHNEIDER
2017-06-26 13:46:15ROUTED TO KEVIN MARTIN