Plan Review Details - Permit 17060769
Plan Review Stops For Permit 17060769 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-11-16 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-11-16 |
Time |
11:30 |
Sent To |
|
|
Notes |
2017-11-16 14:57:09 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17060769 / SHELL BUILDING | | ADD: 1560 PALM BEACH LAKES BLVD. | | CONT: IBIS BUILDING | | TEL: 561-318-8408 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 4TH REVIEW | | DATE: THURS. NOV. 16/ 2017 | | ACTION: BUILDING PROVISO | | | | 1) PROVISO: 2014 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | 110.3.9 AND GUIDELINES AND POLICIES FOR PROJECTS | | CONCERNING RESIDENT INSPECTORS. COMMENT # 14. ( 3 ) | | COPIES OF ALL SHOP DRAWINGS (PRODUCT APPROVALS, | | TRUSSES, BAR JOIST, ETC.) MUST BE SUBMITTED TO THE | | BUILDING DEPARTMENT. TWO REVIEWED SETS OF DOCUMENTS | | WILL BE RETURNED TO THE JOB SITE BEFORE ANY OF THE | | ABOVE IS INSTALLED ON THE JOB. | | | | 2) PROVISO: PLEASE CALL THE CITY OF WEST PALM BEACHS | | AUTOMATED TELEPHONE INSPECTIONS LINE (561) 805-6700) | | FOR IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | INSPECTIONS. | | | | 3) BUILDING PROVISO/ DEFERRED SUBMITTALS: 2014 FBC-B | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS ,MULLIONS | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, ROOF TOP | | VENTILATORS | | (G) PRE-ENGINEERED A/C STANDS | | | | 4) BUILDING PROVISO/ DEFERRED SUBMITTALS: IDENTIFY | | GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE PRODUCT | | APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND | | BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL | | PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE OPENING | | WIDTH & HEIGHT, TYPE OF GLAZING, MULLION INFORMATION IF | | REQUIRED, ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH | | OPENING SIZE. 2014 FBC-B 1405.13.1 INSTALLATION. | | WINDOWS AND DOORS SHALL BE INSTALLED IN ACCORDANCE WITH | | APPROVED MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND | | SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND | | SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING | | USED IN THE TESTS. | | | | 5) BUILDING PROVISO/ DEFERRED SUBMITTALS: FBC 107.3.4.1 | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED | | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | 6) BUILDING PROVISO/ DEFERRED SUBMITTALS: 107.2.1.2 FOR | | ROOF ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION | | DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE | | TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING | | REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE | | RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT | | EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE | | WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE. | | FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING | | SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF | | ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF | | ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | 7) BUILDING PROVISO/ DEFERRED SUBMITTALS: EFIS SYSTEMS: | | PLEASE PROVIDE THE PRODUCT APPROVAL FOR THE SYSTEM TO | | BE INSTALLED. PLEASE ALSO PROVIDE THE MANUFACTURERS | | INSTALLATION BROCHURE PROVIDING COMPLIANCE WITH 2014 | | FBC-B SECTIONS; | | 1408.2 PERFORMANCE CHARACTERISTICS. | | 1408.3 STRUCTURAL DESIGN. | | 1408.4 WEATHER RESISTANCE. | | 1408.4.1 EIFS WITH DRAINAGE. | | 408.4.1.1 WATER-RESISTIVE BARRIER. | | 1408.5 INSTALLATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-10-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-10-30 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-10-30 |
Time |
08:03 |
Sent To |
|
|
Notes |
2017-10-30 09:16:47 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17060769 | | ADD: 1560 PALM BEACH LAKES BLVD. | | CONT: IBIS BUILDING | | TEL: 561-318-8408 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: MON. OCT. 30/ 2017 | | ACTION: DENIED | | | | 1-2) COMPLIED. | | | | 3) SEMI-COMPLIED, ONLY 2 SOILS REPORTS SUBMITTED 3 | | REQUIRED FOR RESIDENT INSPECTOR. | | | | 4) 3RD REQUEST. RESPONSE, NOT YET SELECTED. RESIDENT | | INSPECTOR 2014 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | 110.3.9 OTHER INSPECTIONS SERVICES. THE BUILDING | | OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE | | INSPECTIONS REQUIRED BY SECTION 109. HE/SHE MAY ACCEPT | | REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION | | SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS | | SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A | | CERTIFICATE CALLED FOR BY ANY PROVISION OF THE | | TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS | | UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A | | RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING | | OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION | | SERVICE IN THE FOLLOWING INSTANCES: | | | | | | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II | | CONSTRUCTION | | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | STRENGTH (F ?C) IN EXCESS OF 3000 POUNDS PER SQUARE | | INCH | | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | METHODS OF CONSTRUCTION BOLTED AND WELDED CONNECTIONS. | | RESIDENT INSPECTOR WILL BE REQUIRED FROM FOUNDATION | | THROUGH ROOF FRAMING, ROOF DECKING, WINDOW FRAME AND | | GLAZING INSTALLATION. | | | | 4A) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL | | PARTIES NOTARIZED AND RETURNED TO THE BUILDING | | DEPARTMENT. | | FORMS SENT TO: [email protected] OCT. 30/ 2017 AT | | 09:15 AM. | | | | 4B) 3RD REQUEST. FOR THE RESIDENT INSPECTOR PLEASE | | PROVIDE A RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS | | PROJECT. THE RESUME' MUST BE ACCOMPANIED BY ALL | | CERTIFICATES AS SPECIFIED HEREIN. THE BUILDING OFFICIAL | | OR HIS DESIGNEE WILL REVIEW THE RESUME'. AFTER THE | | RESUME' IS REVIEWED, AN INTERVIEW WILL BE SCHEDULED | | | | 4C) 3RD REQUEST. THE CONTRACTOR WILL PRODUCE A JOB | | SUMMARY OR HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | 4D) 3RD REQUEST. NOTE FOR PAPER PLANS 3 SETS OF | | DOCUMENTS ARE REQUIRED. | | | | 4E) PROVISO: 2010 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | 110.3.9 AND GUIDELINES AND POLICIES FOR PROJECTS | | CONCERNING RESIDENT INSPECTORS. COMMENT # 14. ( 3 ) | | COPIES OF ALL SHOP DRAWINGS (HANDRAILS, PRECAST JOINT | | AND SLABS, PRODUCT APPROVALS, TRUSSES, BAR JOIST, ETC.) | | MUST BE SUBMITTED TO THE BUILDING DEPARTMENT. TWO | | REVIEWED SETS OF DOCUMENTS WILL BE RETURNED TO THE JOB | | SITE BEFORE ANY OF THE ABOVE IS INSTALLED ON THE JOB. | | | | 4F) PROVISO: PLEASE CALL THE CITY OF WEST PALM BEACHS | | AUTOMATED TELEPHONE INSPECTIONS LINE (561) 805-6700) | | FOR IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | INSPECTIONS. | | | | 5) COMPLIED. | | | | 6) BUILDING PROVISO/ DEFERRED SUBMITTALS: 2014 FBC-B | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS ,MULLIONS | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, ROOF TOP | | VENTILATORS | | (G) PRE-ENGINEERED A/C STANDS | | | | 7) BUILDING PROVISO/ DEFERRED SUBMITTALS: IDENTIFY | | GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE PRODUCT | | APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND | | BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL | | PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE OPENING | | WIDTH & HEIGHT, TYPE OF GLAZING, MULLION INFORMATION IF | | REQUIRED, ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH | | OPENING SIZE. 2014 FBC-B 1405.13.1 INSTALLATION. | | WINDOWS AND DOORS SHALL BE INSTALLED IN ACCORDANCE WITH | | APPROVED MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND | | SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND | | SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING | | USED IN THE TESTS. | | | | 8) BUILDING PROVISO/ DEFERRED SUBMITTALS: FBC 107.3.4.1 | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED | | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | 9) BUILDING PROVISO/ DEFERRED SUBMITTALS: 107.2.1.2 FOR | | ROOF ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION | | DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE | | TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING | | REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE | | RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT | | EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE | | WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE. | | FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING | | SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF | | ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF | | ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | 10) BUILDING PROVISO/ DEFERRED SUBMITTALS: EFIS | | SYSTEMS: PLEASE PROVIDE THE PRODUCT APPROVAL FOR THE | | SYSTEM TO BE INSTALLED. PLEASE ALSO PROVIDE THE | | MANUFACTURERS INSTALLATION BROCHURE PROVIDING | | COMPLIANCE WITH 2014 FBC-B SECTIONS; | | 1408.2 PERFORMANCE CHARACTERISTICS. | | 1408.3 STRUCTURAL DESIGN. | | 1408.4 WEATHER RESISTANCE. | | 1408.4.1 EIFS WITH DRAINAGE. | | 408.4.1.1 WATER-RESISTIVE BARRIER. | | 1408.5 INSTALLATION. | | | | 11) COMPLIED. FOR SHELL BUILDING. | | | | 12) COMPLIED. PALM BEACH COUNTY IMPACT FEES. | | | | 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-08-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-26 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-08-26 |
Time |
06:30 |
Sent To |
|
|
Notes |
2017-08-26 07:12:52 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17060769 | | ADD: 1560 PALM BEACH LAKES BLVD. | | CONT: TBD/ TO BE DETERMINED | | TEL: 407-786-9724 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: SAT. AUGUST 26/ 2017 | | ACTION: DENIED | | | | 1-2) COMPLIED. | | | | 3) 2ND REQUEST. RESPONSE, NOT YET SELECTED. THE SOILS | | REPORTS BY UNIVERSAL ENGINEERING SCIENCES DATED AUGUST | | 04/2016 UES REPORT NO. 13869 INDICATES THAT THREE SOILS | | SAMPLES TEST RESULT INDICATE ORGANIC CONTENTS RANGED | | FROM 10.7 TO 26.8 PERCENT AND MOISTURE CONTENTS RANGING | | FROM 50.6 TO 121 PERCENT. ORGANIC SOILS (10 PERCENT OR | | HIGHER) ENCOUNTERED IN STRUCTURAL AREAS SHOULD BE | | REMOVED AND REPLACED WITH GOOD QUALITY FILL. PLEASE | | PROVIDE WHICH SOILS ENGINEERING COMPANY WILL BE | | OVERSEEING THE REMOVAL AND REPLACEMENT OF GOOD QUALITY | | FILL IN ACCORDANCE TO THE SPECIFICATIONS AND PROCEDURES | | OUTLINED IN THE SITE PREPARATION SECTION OF THIS | | REPORT? 107.2.1.3 ADDITIONAL INFORMATION WILL BE | | REQUIRED. 2014 FBC-B 1803.4 QUALIFIED REPRESENTATIVE. | | | | 4) 2ND REQUEST. RESPONSE, NOT YET SELECTED. RESIDENT | | INSPECTOR 2014 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | 110.3.9 OTHER INSPECTIONS SERVICES. THE BUILDING | | OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE | | INSPECTIONS REQUIRED BY SECTION 109. HE/SHE MAY ACCEPT | | REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION | | SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS | | SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A | | CERTIFICATE CALLED FOR BY ANY PROVISION OF THE | | TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS | | UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A | | RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING | | OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION | | SERVICE IN THE FOLLOWING INSTANCES: | | | | | | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II | | CONSTRUCTION | | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | STRENGTH (F ?C) IN EXCESS OF 3000 POUNDS PER SQUARE | | INCH | | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | METHODS OF CONSTRUCTION BOLTED AND WELDED CONNECTIONS. | | RESIDENT INSPECTOR WILL BE REQUIRED FROM FOUNDATION | | THROUGH ROOF FRAMING, ROOF DECKING, WINDOW FRAME AND | | GLAZING INSTALLATION. | | | | 4A) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL | | PARTIES NOTARIZED AND RETURNED TO THE BUILDING | | DEPARTMENT. | | FORMS SENT TO: [email protected] 06/27/2017 97:15 AM | | | | 4B) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | AN INTERVIEW WILL BE SCHEDULED | | | | 4C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | 4D) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE | | PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND | | BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO | | SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR | | THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP | | INSPECTORS. | | | | 4E) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 AND | | GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | RESIDENT INSPECTORS. COMMENT # 14. 3 COPIES OF ALL SHOP | | DRAWINGS (HANDRAILS, PRECAST JOINT AND SLABS, PRODUCT | | APPROVALS, TRUSSES, BAR JOIST, ETC.) MUST BE SUBMITTED | | TO THE BUILDING DEPARTMENT. TWO REVIEWED SETS OF | | DOCUMENTS WILL BE RETURNED TO THE JOB SITE BEFORE ANY | | OF THE ABOVE IS INSTALLED ON THE JOB. | | | | 4F) PLEASE CALL THE CITY OF WEST PALM BEACHS AUTOMATED | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR | | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | INSPECTIONS. | | | | 5) COMPLIED. | | | | 6) BUILDING PROVISO/ DEFERRED SUBMITTALS: 2014 FBC-B | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS ,MULLIONS | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, ROOF TOP | | VENTILATORS | | (G) PRE-ENGINEERED A/C STANDS | | | | 7) BUILDING PROVISO/ DEFERRED SUBMITTALS: IDENTIFY | | GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE PRODUCT | | APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND | | BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL | | PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE OPENING | | WIDTH & HEIGHT, TYPE OF GLAZING, MULLION INFORMATION IF | | REQUIRED, ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH | | OPENING SIZE. 2014 FBC-B 1405.13.1 INSTALLATION. | | WINDOWS AND DOORS SHALL BE INSTALLED IN ACCORDANCE WITH | | APPROVED MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND | | SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND | | SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING | | USED IN THE TESTS. | | | | 8) BUILDING PROVISO/ DEFERRED SUBMITTALS: FBC 107.3.4.1 | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED | | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | 9) BUILDING PROVISO/ DEFERRED SUBMITTALS: 107.2.1.2 FOR | | ROOF ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION | | DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE | | TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING | | REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE | | RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT | | EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE | | WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE. | | FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING | | SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF | | ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF | | ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | 10) BUILDING PROVISO/ DEFERRED SUBMITTALS: EFIS | | SYSTEMS: PLEASE PROVIDE THE PRODUCT APPROVAL FOR THE | | SYSTEM TO BE INSTALLED. PLEASE ALSO PROVIDE THE | | MANUFACTURERS INSTALLATION BROCHURE PROVIDING | | COMPLIANCE WITH 2014 FBC-B SECTIONS; | | 1408.2 PERFORMANCE CHARACTERISTICS. | | 1408.3 STRUCTURAL DESIGN. | | 1408.4 WEATHER RESISTANCE. | | 1408.4.1 EIFS WITH DRAINAGE. | | 408.4.1.1 WATER-RESISTIVE BARRIER. | | 1408.5 INSTALLATION. | | | | 11) COMPLIED FOR SHELL BUILDING. | | | | 12) 2ND REQUEST. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-06-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-27 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-26 |
Time |
15:27 |
Sent To |
|
|
Notes |
2017-06-27 09:06:40 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17060769 | | ADD: 1560 PALM BEACH LAKES BLVD. | | CONT: TBD/ TO BE DETERMINED | | TEL: 407-786-9724 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MON. JUNE 26/ 2017 | | ACTION: DENIED | | | | 1) PLEASE PROVIDE A SURVEY WITH THE PROPOSED BUILDING | | LOCATION AND DISTANCES TO THE PROPERTY LINES SO | | COMPLIANCE WITH 2014 FBC-B TABLE 602 FOR FIRE | | RESISTANCE REQUIREMENTS FOR EXTERIOR WALLS BASED ON | | FIRE SEPARATION DISTANCE AND PERCENTAGE OF ALLOWABLE | | OPENINGS BASED ON FIRE SEPARATION PER TABLE 705.8. | | | | 2) THE SOILS REPORTS BY UNIVERSAL ENGINEERING SCIENCES | | DATED AUGUST 04/2016 UES REPORT NO. 13869 HAS A COPY OF | | A STAMPED SEAL AND SIGNATURE. | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | FL ADMIN CODE 61G15-23.002 ENGINEERS. EFFECTIVE DATE | | 05/06/2009. (2)(A) EVERY SHEET OF PLANS AND PRINTS | | WHICH MUST BE SEALED UNDER THE PROVISIONS OF CHAPTER | | 471, F.S., SHALL BE SEALED, SIGNED AND DATED BY THE | | PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE. | | 3) THE SOILS REPORTS BY UNIVERSAL ENGINEERING SCIENCES | | DATED AUGUST 04/2016 UES REPORT NO. 13869 INDICATES | | THAT THREE SOILS SAMPLES TEST RESULT INDICATE ORGANIC | | CONTENTS RANGED FROM 10.7 TO 26.8 PERCENT AND MOISTURE | | CONTENTS RANGING FROM 50.6 TO 121 PERCENT. ORGANIC | | SOILS (10 PERCENT OR HIGHER) ENCOUNTERED IN STRUCTURAL | | AREAS SHOULD BE REMOVED AND REPLACED WITH GOOD QUALITY | | FILL. PLEASE PROVIDE WHICH SOILS ENGINEERING COMPANY | | WILL BE OVERSEEING THE REMOVAL AND REPLACEMENT OF GOOD | | QUALITY FILL IN ACCORDANCE TO THE SPECIFICATIONS AND | | PROCEDURES OUTLINED IN THE SITE PREPARATION SECTION OF | | THIS REPORT? 107.2.1.3 ADDITIONAL INFORMATION WILL BE | | REQUIRED. 2014 FBC-B 1803.4 QUALIFIED REPRESENTATIVE. | | | | 4) 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER | | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, | | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED | | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS | | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: | | | | | | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II | | CONSTRUCTION | | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | STRENGTH (F ?C) IN EXCESS OF 3000 POUNDS PER SQUARE | | INCH | | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | METHODS OF CONSTRUCTION BOLTED AND WELDED CONNECTIONS. | | RESIDENT INSPECTOR WILL BE REQUIRED FROM FOUNDATION | | THROUGH ROOF FRAMING, ROOF DECKING, WINDOW FRAME AND | | GLAZING INSTALLATION. | | | | 4A) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL | | PARTIES NOTARIZED AND RETURNED TO THE BUILDING | | DEPARTMENT. | | FORMS SENT TO: [email protected] 06/27/2017 97:15 AM | | | | 4B) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | AN INTERVIEW WILL BE SCHEDULED | | | | 4C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | 4D) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE | | PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND | | BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO | | SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR | | THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP | | INSPECTORS. | | | | 4E) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 AND | | GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | RESIDENT INSPECTORS. COMMENT # 14. 3 COPIES OF ALL SHOP | | DRAWINGS (HANDRAILS, PRECAST JOINT AND SLABS, PRODUCT | | APPROVALS, TRUSSES, BAR JOIST, ETC.) MUST BE SUBMITTED | | TO THE BUILDING DEPARTMENT. TWO REVIEWED SETS OF | | DOCUMENTS WILL BE RETURNED TO THE JOB SITE BEFORE ANY | | OF THE ABOVE ARE INSTALLED ON THE JOB. | | | | 4F) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR | | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | INSPECTIONS. | | | | 5) SHEETS A5.1 DETAILS 1 & 4, A5.2 DETAILS 1 & 3, A5.3 | | DETAILS 1, 2, &4, A6.2 DETAILS 1 & 2, S3.1, S3.2 & S3.3 | | ALL WILL NEED TO SHOW COMPLIANCE WITH 2014 FBC-B 1403.8 | | (5) & 2114.2. | | 2014 FBC-B 1403.8 (5). | | MASONRY VENEERS CONSTRUCTED IN ACCORDANCE WITH SECTION | | 2114.2. | | 2114.2 CONCRETE BEARING LEDGE. BRICK, STONE OR OTHER | | VENEER SHALL BE SUPPORTED BY A CONCRETE BEARING LEDGE | | AT LEAST EQUAL TO THE TOTAL THICKNESS OF THE BRICK, | | STONE OR OTHER VENEER, WHICH IS POURED INTEGRALLY WITH | | THE CONCRETE FOUNDATION. NO SUPPLEMENTAL CONCRETE | | FOUNDATION POURS WHICH WILL CREATE A HIDDEN COLD JOINT | | SHALL BE USED WITHOUT SUPPLEMENTAL TREATMENT IN THE | | FOUNDATION, UNLESS THERE IS AN APPROVED PHYSICAL | | BARRIER. AN APPROVED PHYSICAL BARRIER SHALL ALSO BE | | INSTALLED FROM BELOW THE WALL SILL PLATE OR FIRST BLOCK | | COURSE HORIZONTALLY TO EMBED IN A MORTAR JOINT. IF | | MASONRY VENEER EXTENDS BELOW GRADE, A TERMITE | | PROTECTIVE TREATMENT MUST BE APPLIED TO THE CAVITY | | CREATED BETWEEN THE VENEER AND THE FOUNDATION, IN LIEU | | OF A PHYSICAL BARRIER. | | EXCEPTION: VENEER SUPPORTED BY A SHELF, ANGLE OR LINTEL | | SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH | | TMS 402/ACI 530/ASCE 5, PROVIDED AT LEAST A 6-INCH (152 | | MM) CLEAR INSPECTION SPACE OF THE FOUNDATION SIDEWALL | | EXTERIOR EXIST BETWEEN THE VENEER AND THE TOP OF ANY | | SOIL, SOD, MULCH OR OTHER ORGANIC LANDSCAPING | | COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK | | IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE. | | | | 6) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS ,MULLIONS | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, ROOF TOP | | VENTILATORS | | (G) PRE-ENGINEERED A/C STANDS | | | | 7) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | MULLION INFORMATION IF REQUIRED, ATTACHMENTS AND | | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2014 FBC-B | | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE | | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S | | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE | | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED | | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. | | | | 8) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 9) 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, | | THE CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE | | AND DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS, | | FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND | | RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED. | | PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE | | COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE | | SPECIFIC SITE. FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY | | ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES | | FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL | | LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF | | ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR | | BOTH INSULATION & THE BASE SHEET AS CALCULATED IN | | COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117. | | CALCULATION PREPARED, SIGNED AND SEALED BY A FLORIDA | | REGISTERED PROFESSIONAL ENGINEER OR REGISTERED | | ARCHITECT. 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | 10) EFIS SYSTEMS: PLEASE PROVIDE THE PRODUCT APPROVAL | | FOR THE SYSTEM TO BE INSTALLED. PLEASE ALSO PROVIDE THE | | MANUFACTURERS INSTALLATION BROCHURE PROVIDING | | COMPLIANCE WITH 2014 FBC-B SECTIONS; | | 1408.2 PERFORMANCE CHARACTERISTICS. | | 1408.3 STRUCTURAL DESIGN. | | 1408.4 WEATHER RESISTANCE. | | 1408.4.1 EIFS WITH DRAINAGE. | | 408.4.1.1 WATER-RESISTIVE BARRIER. | | 1408.5 INSTALLATION. | | | | 11) SHEET A2.1 ON THE DOOR HARDWARE SCHEDULE ALL THE | | EXTERIOR DOORS SHOW HARDWARE GROUP 1 WITH PUSH/ PULL | | HARDWARE. PLEASE NOTE WHEN THE OCCUPANT LOAD IS 50 OR | | MORE OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR | | LOCK UNLESS IT IS PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | | 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-14 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-14 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-22 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-22 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-07-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-07-13 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-07-13 |
Time |
09:40 |
Sent To |
|
|
Notes |
2017-07-13 10:07:46 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW COMMENTS: | | | | 1. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO | | INDICATE NEC 110.16. ARC FLASH WARNING SIGNS AND NEC | | 110.24- AVAILABLE FAULT CURRENT- FIELD MARKINGS; SEE | | VERBIAGE IN CODE. | | 2. NOTE 8 ON RISER DIAGRAM STATES THE EQUIPMENT | | GROUNDING CONDUCTOR (EGC) IS SIZED AT 1/0 COPPER, WHICH | | IS NOT PER CODE FOR A 1200 AMP SYSTEM. PROVIDE | | CORRECTION. NEC 250.122 | | 3. PROVIDE ACTUAL FAULT CURRENT FROM FPL. AN ESTIMATED | | VALUE IS NOT ACCEPTABLE. NEC 110.10 | | 4. SHEET EP1.2, PLEASE IDENTIFY WHICH LIGHT FIXTURE | | MODEL WILL BE USED. FBC 107.2.1 | | 5. INDICATE VOLTAGE DROP COMPLIANCE WITH FBC ENERGY | | CODE. A NOTE WILL SUFFICE. NOTE SHOULD INCLUDE | | INDICATION OF SUBMITTAL OF COMPLETION DOCUMENTS PER FBC | | C405.7.4 FBC C405.7.3 | | 6. LOAD CALCULATIONS PROVIDED IS INCOMPLETE. PROVIDE | | ACCURATE LOAD CALCULATIONS TO JUSTIFY SERVICE SIZE. NEC | | 215.2, 215.5, 220; FBC 107.2.1 | | 7. WHY IS WIRING SHOWN TO THE RTU'S IN UNIT 9, BUT NOT | | IN ANY OTHER UNIT? WHY IS THERE NO WIRING SHOWN TO | | EMERGENCY AND EXIT LIGHTS REQUIRED? PROVIDE | | CLARIFICATION. FBC 107.2.1 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-11-14 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-11-14 |
Time |
12:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2017-10-02 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2017-10-02 |
Time |
16:11 |
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2017-10-02 |
Time |
16:11 |
Sent To |
ENG |
|
Notes |
2017-10-02 15:54:40 | PLAN REIVEW FOR SITE DEVELOPMENT THROUGH ENGINEERING | | AND ENGINEER OF RECORD - CIVIL. | | | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-11-15 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-11-15 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-11-15 |
Time |
10:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-08-25 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-08-25 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-08-25 |
Time |
11:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-06-28 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-06-28 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-06-28 |
Time |
11:55 |
Sent To |
|
|
Notes |
2017-06-28 12:14:56 | 1560 PALM BEACH LAKES BOULEVARD | | PERMIT #17060769 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | *****SHELL ONLY***** SEPARATE PERMITS AND SUBPERMITS | | WILL BE NEEDED FOR TENANT FITOUT WORK. NO CERTIFICATE | | OF OCCUPANCY WILL BE GRANTED FOR THE SHELL-ONLY WORK. | | | | DESIGN SHALL CONFORM TO THE 5TH EDITION OF THE FLORIDA | | FIRE PREVENTION CODE WHICH CONTAINS THE 2012 EDITION OF | | BOTH NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS. | | | | NO SITE OR CIVIL PLANS SUBMITTED SHOWING FIRE HYDRANTS | | FOR FIRE DEPARTMENT ACCESS ROADS/LANES. | | | | PLANS DO NOT INDICATE ANY PORTABLE FIRE EXTINGUISHERS, | | EMERGENCY LIGHTING, ILLUMINATED EXIT SIGNS, TACTILE | | SIGNAGE. | | | | PER NFPA 101 SECTION 8.3.2.4, EACH FIRE BARRIER SHALL | | BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING | | READING "FIRE BARRIER-PROTECT ALL OPENINGS." CHARACTERS | | SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN | | WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 | | FEET ON CENTER. | | | | FIRE PROTECTION BACKFLOW PREVENTER IS LOCATED CLOSER | | THAN 40 FEET FROM THE BUILDING. | | PER NFPA 24 SECTION 6.2.1, ALL CONNECTIONS TO PRIVATE | | FIRE SERVICE MAINS FOR FIRE PROTECTION SYSTEMS SHALL BE | | ARRANGED IN ACCORDANCE WITH ONE OF THE FOLLOWING SO | | THAT THEY CAN BE ISOLATED: | | (1)A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40 | | FEET FROM THE BUILDING. | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST | | INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED | | CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE | | BUILDING AS THE HEIGHT OF THE WALL FACING THE POST | | INDICATOR VALVE. | | (2) A WALL POST INDICATOR VALVE | | (3) AN INDICATING VALVE IN A PIT, INSTALLED IN | | ACCORDANCE WITH SECTION 6.4 | | (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING | | VALVE NOT LESS THAN 40 FEET FROM THE BUILDING. | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A | | BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE | | SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET | | BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF | | THE WALL FACING THE BACKFLOW PREVENTER. | | (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM | | ACCESSIBLE FROM THE EXTERIOR | | (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE | | ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE | | AUTHORITY HAVING JURISDICTION | | | | PROVIDE A DRAWING NOTE INDICATING: AN APPROVED WRITTEN | | EMERGENCY PLAN FOR THE EMERGENCY EGRESS OF OCCUPANTS IS | | REQUIRED PRIOR TO OCCUPANCY. ALL EMPLOYEES SHALL BE | | INSTRUCTED AND PERIODICALLY DRILLED WITH RESPECT TO | | THEIR DUTIES UNDER THE PLAN. EMPLOYEES SHALL BE | | PERIODICALLY TRAINED OR INSTRUCTED IN THE USE OF | | PORTABLE FIRE EXTINGUISHERS. | | | | A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED | | AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON | | THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED DURING PLAN RESUBMISSION. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
F |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-11-16 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-11-06 |
Time |
15:39 |
Sent To |
|
|
Notes |
2017-11-16 09:36:46 | 11/16 TO JW DESK | | | | | 2017-11-07 15:39:39 | C31 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-10-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-10-30 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-10-26 |
Time |
13:35 |
Sent To |
|
|
Notes |
2017-10-27 13:35:38 | RESUB ROUTED TO JWITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-10-04 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-10-04 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-08-22 |
Time |
16:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-08-09 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-08-09 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-06-15 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
N |
Date |
2017-10-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-10-30 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-10-30 |
Time |
08:09 |
Sent To |
|
|
Notes |
2017-10-30 08:22:39 | OCT. 30/2017 | | PALM BEACH COUNTY IMPACT FEES PAID | | DATE RECEIVED: 10/26/2017 | | TRACKING NUMBER: MU-2017-0289-0000 | | RECEIPT NUMBER: 2017-1026-304 | | TOTAL $207,112.42 | | J. WITMER W. P. B. PLAN REVIEW | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2017-08-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-26 |
Time |
07:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-08-26 |
Time |
07:13 |
Sent To |
|
|
Notes |
2017-08-26 07:13:24 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-06-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-26 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-26 |
Time |
16:56 |
Sent To |
|
|
Notes |
2017-06-26 16:57:19 | IMPACT FEES | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-11-14 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-11-14 |
Time |
12:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-09-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-09-20 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-09-20 |
Time |
12:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-07-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-07-07 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-07-07 |
Time |
07:32 |
Sent To |
|
|
Notes |
2017-07-07 12:46:07 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17060769 | | 7/7/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M2.1: THE NUMBER OF PEOPLE FOR THE OCCUPANCIES | | LISTED IN THE O/A SCHEDULE ARE NOT IN COMPLIANCE WITH | | EITHER TABLE 6-1 ASHRAE 62.1-2010, OR TABLE 403.3 | | FBC-14 MECHANICAL. OCCUPANT DENSITY FOR RETAIL IS 15 | | PERSONS PER 1000 SQ. FT. WHICH RESULTS IN 32 PEOPLE FOR | | RTU-1, AND 19 PEOPLE FOR RTU-2-8. CONCERNING THE | | RESTAURANT OCCUPANCY (RTU- 9A, 9B, 9C) PLEASE PROVIDE A | | BREAKDOWN CALCULATION THAT DINING AND OTHER AREAS FROM | | THE KITCHEN AREA. PLEASE NOTE THAT THE OCCUPANT DENSITY | | FOR DINING IS 70 PER 1000 SQ. FT. PLEASE REVISE THE | | SCHEDULE ACCORDINGLING. | | | | 2) PLEASE ADJUST THE AC COOLING AND HEATING | | CALCULATIONS TO INCLUDE THE ACCURATE NUMBER OF | | OCCUPANTS AND ALSO THE APPLIANCE LOADS FOR EACH | | OCCUPANCY. | | | | 3) SHEETS M2.1 & S4.3: PLEASE CHOOSE ONE OF THE TWO RTU | | AND CURB INSTALLATION DETAILS WILL BE USED, AND MATCH | | THE OTHER DETAIL TO IT. THERE ARE DIFFERENCES BETWEEN | | THE TYPES AND NUMBER QUANTITIES OF FASTENERS AND ANCHOR | | BOLTS. CORRECT THE WIND SPEED SHOWN ON M2.1 TO 170 MPH. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-11-14 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-11-14 |
Time |
12:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-09-27 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-09-27 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-09-27 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-07-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-13 |
Time |
18:51 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-13 |
Time |
18:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-11-14 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-11-14 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-09-22 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-09-20 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-07-18 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-07-18 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-07-18 |
Time |
15:48 |
Sent To |
|
|
Notes |
2017-07-18 15:49:34 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 07.18.2017 | | PERMIT NO.: 17060769 | | ADDRESS: 1560 PALM BEACH LAKES BOULEVARD | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | SHALL BE PROVIDED. | | | | 2. TWO (2) COPIES OF A SITE PLAN SHALL BE PROVIDED. THE | | SITE PLANS SHALL INCLUDE THE FOLLOWING: | | | | A. DATE, NORTH ARROW, AND A GRAPHIC SCALE. | | | | B. VICINITY MAP SHOWING THE PROPERTY IN RELATION TO | | THE SURROUNDING AREA. | | | | C. LOCATION OF THE PROPERTY LINE, RIGHT-OF-WAY, | | PROPOSED/EXISTING EASEMENTS, WATER COURSES AND OTHER | | ESSENTIAL FEATURES. | | | | D. STREETS, DRIVEWAYS, INTERSECTIONS, CURBS CUTS AND | | TURNING LANES ADJACENT TO OR ACROSS FROM THE SUBJECT | | PROPERTY. | | | | E. THE OUTLINES OF ALL BUILDINGS SHOWING THEIR | | PROPOSED USES, SETBACKS, DIMENSIONS, FLOOR AREA, NUMBER | | OF STORIES, HEIGHT AND POINTS OF ACCESS. | | | | F. LOCATION AND DIMENSIONS OF ALL PERIMETER TREATMENT | | (SIDEWALKS, FENCES, WALLS, OR BERMS). | | | | G. LOCATION, HEIGHT AND SIZE OF ALL FREESTANDING SIGNS | | AND OTHER ACCESSORY STRUCTURES. | | | | H. MEANS OF VEHICULAR AND PEDESTRIAN ACCESS TO AND | | FROM THE SITE. | | | | I. LAYOUT AND LOCATION OF ALL OFF-STREET PARKING, | | LOADING AND OTHER VEHICULAR USE AREAS. | | | | J. LOCATION OF ALL DISABLED SPACES, RAMPS AND SIGNS. | | | | K. LOCATION AND SCREENING OF ALL GARBAGE RECEPTACLES. | | | | L. STANDARD CITY DETAILS OF PARKING (SMALL CAR, | | HANDICAP SPACE, STANDARD SPACE), HANDICAP RAMPS, | | DRIVEWAYS, DUMPSTERS AND SIGNS. | | | | M. SUPPLY A DATA TABLE IN THE FOLLOWING FORMAT: | | | | I. EXISTING/PROPOSED LAND USE AND ZONING. | | | | II. TOTAL ACRES OF THE PROJECT. | | | | III. TOTAL GROSS BUILDING SQUARE FOOTAGE. | | | | IV. PERCENT OF OPEN SPACE, LANDSCAPING, BUILDING | | COVERAGE & IMPERMEABLE SURFACE. | | | | V. ACRES AND PERCENT OF WATER BODIES. | | | | VI. DENSITY AND NUMBER OF DWELLING UNITS | | (RESIDENTIAL). | | | | VII. PARKING COMPUTATIONS (PARKING REQUIRED, | | PROVIDED, ETC.) | | | | VIII. FLOOR AREA RATIO (FAR). | | | | 3. PURSUANT TO THE HOME DEPOT COMMERCIAL PLANNED | | DEVELOPMENT (CPD) DEVELOPMENT ORDER (RESOLUTION NO. | | 101-17), THE FOLLOWING SHALL BE ADDRESSED PRIOR TO THE | | ISSUANCE OF A BUILDING PERMIT: | | | | A. AN EASEMENT ABANDONMENT MUST BE FILED AND APPROVED | | BY THE CITY OF WEST PALM BEACH FOR THE SIX (6) FOOT | | UTILITY EASEMENT (PLAT BOOK 86, PAGE 13) THAT IS | | LOCATED BENEATH THE PROPOSED BUILDING. | | | | B. THE FINAL PLACEMENT, ANGLE, AND SIZE OF THE | | DUMPSTER ENCLOSURE SHALL BE REVIEWED AND APPROVED BY | | THE CITY?S PUBLIC WORKS DEPARTMENT. PLEASE PROVIDE | | WRITTEN APPROVAL FROM PETER BIENIEK, DIRECTOR OF PUBLIC | | WORKS, OR OTHER AUTHORIZED INDIVIDUAL. MR. BIENIEK MAY | | BE REACHED AT 561.494.1099 OR [email protected]. | | | | 4. A SEPARATE LANDSCAPE PERMIT SHALL BE OBTAINED. TWO | | (2) COPIES OF SIGNED/SEALED LANDSCAPE PLANS SHALL BE | | SUBMITTED TO THE BUILDING DIVISION WITH A PERMIT | | APPLICATION. PLEASE NOTE THE FOLLOWING SHALL BE | | ADDRESSED PRIOR TO ISSUANCE OF THE LANDSCAPE PERMIT | | (PER RESOLUTION NO. 101-17): | | | | A. LOCATIONS OF ROOT BARRIERS SHALL BE INDICATED TO | | PROTECT INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS | | INCLUDES WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, | | AND ANY FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE | | ROOTS. | | | | B. TREES/PALMS SHOWN DIRECTLY ON TOP OF THE WATER | | SERVICE AND SEWER LINE SHALL BE ADJUSTED TO AVOID | | CONFLICTS AND ADD ROOT BARRIERS WHERE NEEDED. | | | | 5. THE BUILDING APPROVED VIA RESOLUTION NO. 101-17 | | CONSISTED OF 15,030 GROSS SQUARE FEET; THE PERMIT | | APPLICATION INDICATES THAT THE BUILDING IS PROPOSED TO | | BE 15,064 SQUARE FEET. ANY INCREASE IN SQUARE FOOTAGE | | SHALL BE REQUIRED TO SUBMIT AN AMENDMENT TO THE HOME | | DEPOT CPD. THE TYPE OF AMENDMENT IS DETERMINED BY THE | | CRITERIA IN SEC. 94-207(E) OF THE CITY?S ZONING AND | | LAND DEVELOPMENT REGULATIONS. PLEASE NOTE THAT | | ADDITIONAL SQUARE FOOTAGE MAY IMPACT THE PARKING | | REQUIREMENTS, AS WELL AS REQUIRE ADDITIONAL TRAFFIC | | CONCURRENCY APPROVALS FROM PALM BEACH COUNTY. | | | | 6. PLEASE CLARIFY WHY THE AWNINGS PROPOSED ON THE | | ?TENANT 2? SPACE ARE OF A DIFFERENT MATERIAL THAN THE | | REST OF THE BUILDING. IT IS STAFF?S DIRECTION THAT | | THESE AWNINGS SHOULD BE OF THE SAME MATERIAL AND STYLE. | | IF THE AWNING OVER THE OUTDOOR SEATING NEEDS TO CONSIST | | OF A FABRIC MATERIAL, THEN IT SHOULD HAVE A PLAIN | | VALENCE (NOT SCALLOPED) TO MATCH THE OVERALL STYLE OF | | THE BUILDING. | | | | 7. ACCORDING TO THE ELEVATIONS AND ELECTRICAL PLAN, ALL | | OF THE METERS ARE SHOWN ON THE EAST ELEVATION OF THE | | BUILDING. STAFF WOULD LIKE TO DISCUSS HOW THESE CAN BE | | SCREENED FROM VIEW THROUGH LANDSCAPING, PAINTING OF THE | | EQUIPMENT, ETC. PLEASE CONTACT ME TO DISCUSS. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
|