Plan Review Details - Permit 17060532
Plan Review Stops For Permit 17060532 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-12-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-12-29 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-12-29 |
Time |
17:07 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-02-20 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-02-07 |
Time |
14:01 |
Sent To |
|
|
Notes |
2018-02-08 14:01:31 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-12-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-12-29 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-12-14 |
Time |
11:30 |
Sent To |
|
|
Notes |
2017-12-15 11:30:21 | RESUB OF REVISION ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-06-15 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-06-13 |
Time |
11:33 |
Sent To |
|
|
Notes |
2017-06-14 11:33:55 | REVISION ROUTED TO CCOLE |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2018-02-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-02-20 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-02-20 |
Time |
16:58 |
Sent To |
I |
|
Notes |
2018-02-20 17:02:35 | 3RD REVIEW FBC-2014 MECHANICAL | | REVISION #17060532 | | MASTER #16041147 | | 12/28/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | COMMENTS #1 AND #3 FROM THE 1ST AND 2ND REVIEWS WERE | | NOT ADDRESSED AND STILL EXIST. I HAVE REPRINTED THE | | COMMENTS BELOW- PLEASE COMPLY. | | | | 1) THE AC CONTRACTOR WHO PREPARED THE REVISED | | MECHANICAL PLAN (KAREN OLIVER) SHALL SUBMIT A | | SUB-PERMIT APPLICATION AS REQUIRED BY SECTION 105.3.1.2 | | ITEM #3 WPB AMENDMENTS TO THE FBC-10 BUILDING. IF SHE | | IS NOT THE INSTALLING MECHANICAL CONTRACTOR ON THE | | PROJECT THAN SHE CANNOT BE THE MECHANICAL DESIGNER. | | | | 3) REFER TO SECTION 602.1: THE NEW AC CLOSETS ARE | | PLENUM ENCLOSURES AND MUST BE CONTRUCTED IN ACCORDANCE | | WITH SECTION 602.2. PLEASE NOTE NON-COMBUSTIBLE CLOSET | | DOORS ARE REQUIRED. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | CCO |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-12-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-12-28 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-12-28 |
Time |
12:05 |
Sent To |
E |
|
Notes |
2017-12-28 12:13:03 | 2ND REVIEW FBC-2014 MECHANICAL | | REVISION #17060532 | | MASTER #16041147 | | 12/28/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | COMMENT #1 AND #3 FROM THE 1ST REVIEW WERE NOT | | ADDRESSED AND STILL EXIST. I HAVE REPRINTED THOSE | | COMMENTS BELOW- PLEASE COMPLY. | | | | ONLY ONE SET OF ENERGY CALCULATIONS AND AC CALCULATIONS | | WERE RESUBMITTED. PLEASE PROVIDE THE SECOND COPIES. | | | | 1) THE AC CONTRACTOR WHO PREPARED THE REVISED | | MECHANICAL PLAN SHALL SUBMIT A SUB-PERMIT APPLICATION | | AS REQUIRED BY SECTION 105.3.1.2 ITEM #3 WPB AMENDMENTS | | TO THE FBC-10 BUILDING. | | | | 3) REFER TO SECTION 602.1: THE NEW AC CLOSETS ARE | | PLENUM ENCLOSURES AND MUST BE CONTRUCTED IN ACCORDANCE | | WITH SECTION 602.2. PLEASE NOTE NON-COMBUSTIBLE CLOSET | | DOORS ARE REQUIRED. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-06-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-06-15 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-06-15 |
Time |
10:36 |
Sent To |
|
|
Notes |
2017-06-15 11:37:22 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17060532 | | 6/15/17 | | | | RESULTS: DENIED. | | | | 1) THE AC CONTRACTOR WHO PREPARED THE REVISED | | MECHANICAL PLAN SHALL SUBMIT A SUB-PERMIT APPLICATION | | AS REQUIRED BY SECTION 105.3.1.2 ITEM #3 WPB AMENDMENTS | | TO THE FBC-10 BUILDING. | | | | 2) THE ENGINEER OF RECORD MAURICE EVAN LORD PE WHO DID | | THE ORIGINAL MECHANICAL DESIGN ON SHEET E-1 MUST | | PROVIDE REVISED ELECTRICAL PLANS TO ACCOMODATE THE NEW | | AC SYSTEM. BECAUSE LORD IS STILL THE MECHANICAL | | DESIGNER OF RECORD, HE MUST REVIEW AND APPROVE THE NEW | | AC DRAWINGS. | | | | 3) REFER TO SECTION 602.1: THE NEW AC CLOSETS ARE | | PLENUM ENCLOSURES AND MUST BE CONTRUCTED IN ACCORDANCE | | WITH SECTION 602.2. PLEASE NOTE NON-COMBUSTIBLE CLOSET | | DOORS ARE REQUIRED. | | | | 4) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | CONDENSATE PUMPS. | | | | 5) SUBMIT TWO COPIES OF THE MIAMI-DADE NOA FOR THE | | CONDENSER TIE DOWN CLIPS AND LIST THE NOA NUMBER BY THE | | CONDENSER DETAIL ON SHEET M.1. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
|