Plan Review Details - Permit 17060531
Plan Review Stops For Permit 17060531
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-09-05 Cont ID  
Sent By jgomez Date 2017-09-05 Time 13:33 Rev Time 0.00
Received By jgomez Date 2017-09-05 Time 07:53 Sent To  
Notes
2017-09-05 07:54:37 
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-07-18 Cont ID  
Sent By jgomez Date 2017-07-17 Time 18:40 Rev Time 0.00
Received By jgomez Date 2017-07-17 Time 12:11 Sent To  
Notes
2017-07-17 15:50:06RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 2- SPECIFY ON PLANS CARBON MONOXIDE ALARMS LOCATION FOR
 ALL THE BEDROOMS AS REQUIRED BY SEC. R315.1
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 3- SPECIFY ON PLANS GUTTERS WITH DOWNSPOUTS AS REQUIRED
 BY SEC. R318.5 FBC-RESIDENTIAL.
  
 4- SPECIFY ON PLANS ROOF VENTILATION AS REQUIRED BY
 SEC. R806 FBC-RESIDENTIAL.
  
 5- SPECIFY ON PLANS COMPLIANCE WITH THE WOOD DECAY
 PROTECTION OF ALL THE FLOOR FRAMING MEMBERS AS REQUIRED
 BY SEC. R317.1 FBC-RESIDENTIAL.
  
 6- SPECIFY ON WALL SECTIONS COMPLIANCE WITH THE 6"
 CLEARANCE AS REQUIRED BY SEC. R318.7 FOR TERMITE
 INSPECTION. REVISE ALL WALL SECTIONS ON SHEET S3 AS
 REQUIRED.
  
 7- PROVIDE COMPLETE FRAMING DETAILS FOR NEW DOORS AND
 WINDOWS. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 8-WALLS SECTION ON SHEET S3:
 A) SPECIFY ALL CONNECTORS OF ALL FRAMING MEMBERS TO
 SHOW COMPLIANCE WITH THE LOAD PATH AS REQUIRED BY SEC.
 R601.2 FBC-RESIDENTIAL. HOW ARE THE STUDS CONNECTED TO
 THE TOP AND BOTTOM PLATES?. SPECIFY CONNECTORS IN ALL
 THE WALL SECTIONS. ALSO, PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS, INCLUDING CONNECTORS FOR THE
 CONSTRUCTION OF THE CRICKETS, SEC. R301.1
 FBC-RESIDENTIAL.
  
 B) SPECIFY THE RISER AND TREAD DIMENSION ON SECTION
 4/S3. SEC. R311.7.5 FBC-RESIDENTIAL.
  
 C) PROVIDE COMPLETE DETAIL SHOWING HOW THE SIMPSON
 "SP1" CONNECTOR IS INSTALLED TO HOLD THE FLOOR JOISTS.
 IT LOOKS LIKE THIS CONNECTOR MAY NO WORK IN THIS
 APPLICATION. REVISE ALL WALLS SECTIONS AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 D) THE ORIENTATION OF THE FLOOR JOIST SHOWN ON SECTIONS
 3/S3 AND 4/S3 DON'T MATCH FOUNDATION PLAN. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 E) WALL SECTION 2/S3: PROVIDE SPECIFICATIONS FOR THE
 CONNECTION OF NEW 12"X12" SPREAD FOOTING TO THE
 EXISTING FOOTING. SEC. R401.2 FBC-RESIDENTIAL.
  
 F) PROVIDE DETAILS AND SPECIFICATIONS FOR FLASHING IN
 ALL AREAS AS REQUIRED BY SEC. R703.8 FBC-RESIDENTIAL.
  
 9- ROOFING MATERIAL IS NOT CLEAR. MATERIALS AND COLOR
 INFORMATION ON SHEET SP-1 AND WEST ELEVATION ON SHEET
 A-4 CALL FOR SHINGLES TO MATCH EXISTING SHINGLES. BUT,
 PRODUCT APPROVAL FL7804-R9 SUBMITTED IS FOR CONCRETE
 ROOF TILE. PRODUCT APPROVAL AND SPECIFICATIONS NEED TO
 MATCH. SEC. 107.2.1 CITY AMENDMENTS. NOTE: IF USING
 CONCRETE TILE, THEN SPECIFY IF EXISTING HOUSE IS GOING
 TO RECEIVE CONCRETE TILE ALSO. AND, PROVIDE ENGINEERING
 ANALYSIS SHOWING THAT THE EXISTING STRUCTURE IS
 ADEQUATE TO RECEIVE THE ADDITIONAL CONCRETE TILE LOAD.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 10- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A) ROOF SHINGLES. NOTE: COORDINATE WITH ITEM #9 ABOVE.
  
 B) ROOF UNDERLAYMENT. FLORIDA PRODUCT APPROVAL
 FL5259-R25 SUBMITTED WAS REVISED. PROVIDE 2 COPIES OF
 REVISED PRODUCT APPROVAL FL5259-R26 AND CLEARLY MARK
 WHICH SPECIFIC UNDERLAYMENT IS GOING TO BE USED.
  
 C) ROOF TILE ADHESIVE AS HIGHLIGHTED ON ROOF TILE
 PRODUCT APPROVAL SUBMITTED. NOTE: COORDINATE WITH ITEM
 #9 ABOVE.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS, DETAILS AND WALL SECTIONS. PROVIDE THE FLORIDA
 PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING THE
 SPECIFIED CONNECTOR. OR DESIGNER OF RECORD TO LIST THE
 FLORIDA PRODUCT APPROVAL NEXT TO EACH SPECIFIED
 CONNECTOR.
  
 11- DESIGNER OF RECORD TO REVIEW AND APPROVE ABOVE
 PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS WITH NEW SET OF
 PLANS. SUBMIT OLD DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-09-14 Cont ID  
Sent By jleahy Date 2017-09-14 Time 16:33 Rev Time 0.00
Received By jleahy Date 2017-09-14 Time 16:33 Sent To I
Notes
2017-09-05 09:24:25REVISED DRAWINGS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-07-03 Cont ID  
Sent By jleahy Date 2017-07-03 Time 07:48 Rev Time 0.00
Received By jleahy Date 2017-07-03 Time 07:26 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-07-17 Cont ID  
Sent By gjohnson Date 2017-07-17 Time 15:52 Rev Time 0.00
Received By gjohnson Date 2017-07-17 Time 15:52 Sent To  
Notes
2017-07-17 15:52:45GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2017-09-07 Cont ID  
Sent By fmittner Date 2017-09-07 Time 11:43 Rev Time 0.00
Received By fmittner Date 2017-09-07 Time 11:43 Sent To  
Notes
2017-09-05 09:23:30REVISED DRAWINGS SUBMITTED. JG.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-06-29 Cont ID  
Sent By fmittner Date 2017-06-29 Time 16:44 Rev Time 0.00
Received By fmittner Date 2017-06-29 Time 16:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-09-14 Cont ID  
Sent By jleahy Date 2017-09-14 Time 16:33 Rev Time 0.00
Received By jleahy Date 2017-08-24 Time 15:46 Sent To  
Notes
2017-08-25 15:47:00R21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-18 Cont ID  
Sent By jgomez Date 2017-07-18 Time 14:40 Rev Time 0.00
Received By jgomez Date 2017-06-13 Time 13:01 Sent To  
Notes
2017-06-14 13:01:14R21

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-09-05 Cont ID  
Sent By jgomez Date 2017-09-05 Time 09:27 Rev Time 0.00
Received By jgomez Date 2017-09-05 Time 09:27 Sent To  
Notes
2017-09-05 09:28:15$236.59 PAID. MU-2017-023084.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-07-18 Cont ID  
Sent By jgomez Date 2017-07-18 Time 13:43 Rev Time 0.00
Received By jgomez Date 2017-07-18 Time 13:43 Sent To  
Notes
2017-07-18 13:43:57 
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-09-05 Cont ID  
Sent By jgomez Date 2017-09-05 Time 16:47 Rev Time 0.00
Received By jgomez Date 2017-09-05 Time 15:38 Sent To  
Notes
2017-09-05 15:41:29 
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-07-18 Cont ID  
Sent By jgomez Date 2017-07-18 Time 13:53 Rev Time 0.00
Received By jgomez Date 2017-07-18 Time 07:50 Sent To  
Notes
2017-07-18 14:06:43RESIDENTIAL (R3) ADDITION/ALTERATION MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- ARCHITECT OF RECORD TO COORDINATE A/C PLAN WITH
 EQUIPMENT SIZING CALCULATIONS SUBMITTED. CFM'S DON'T
 MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 2- ARCHITECT TO SPECIFY ON THE A/C PLAN THE CFM'S FOR
 THE EXISTING LIVING ROOM. SEC. 107.3.5.3(10) CITY
 AMENDMENTS.
  
 3- ARCHITECT TO SPECIFY ON PLANS THE EQUIPMENT
 MANUFACTURER AND MODEL #. SEC. 107.3.5.3(10) CITY
 AMENDMENTS. COORDINATE WITH THE EQUIPMENT SIZING
 CALCULATIONS SUBMITTED.
  
 4- ARCHITECT TO CLARIFY WHY THE RETURN AIR DUCTWORK IS
 CONNECTED TO THE DISCONNECT?. REVISE AS REQUIRED. SEC.
 107.2.1 CITY AMENDMENTS.
  
 5- ARCHITECT TO SPECIFY ON A/C PLAN COMPLIANCE WITH THE
 BALANCED RETURN AIR FOR THE NEW FAMILY ROOM AS REQUIRED
 BY SEC. M1602.4 FBC-RESIDENTIAL.
  
 6- PERSON PREPARING THE EQUIPMENT SIZING CALCULATIONS
 TO CLARIFY WHY SPECIFYING 10 PEOPLE FOR A 3 BEDROOM
 HOUSE. TYPICALLY A 3 BEDROOM HOUSE DOESN'T HAVE 10
 OCCUPANTS. NUMBER OF OCCUPANTS MAY AFFECT THE SIZING OF
 THE EQUIPMENT. EQUIPMENT SIZING SHALL BE DONE BASED ON
 THE ACTUAL NUMBER OF PEOPLE. PROVIDE JUSTIFICATIONS OF
 WHY 10 PEOPLE. CLARIFY/REVISE AS REQUIRED. SEC. 107.2.1
 CITY AMENDMENTS.
  
 7- EQUIPMENT SIZING CALCULATIONS SUBMITTED ARE
 INCOMPLETE. NEED TO PROVIDE COMPLETE INFORMATION FOR
 THE EQUIPMENT. COORDINATE WITH ARCHITECT'S A/C PLAN.
 ALSO, SEE ARCHITECT'S A/C PLAN FOR CORRECT FLOOR LAYOUT
 AND LOCATION OF REGISTERS. SEC. 107.3.5.3(10) CITY
 AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS WITH NEW SET OF
 PLANS. SUBMIT OLD DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-07-05 Cont ID  
Sent By gjohnson Date 2017-07-05 Time 10:33 Rev Time 0.00
Received By gjohnson Date 2017-07-05 Time 09:45 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2017-09-05 Cont ID  
Sent By jgomez Date 2017-09-05 Time 12:57 Rev Time 0.00
Received By jgomez Date 2017-09-05 Time 11:44 Sent To  
Notes
2017-09-05 11:45:39MAIN HOUSE R-ROOFING IS NOT PART OF THE SCOPE OF WORK
 FOR THIS PERMIT. SEE PERMIT #17050703 FOR MAIN HOUSE
 RE-ROOFING. JG.
  
 1) ROOF TILE FL7804-R9.
 2) UNDERLAYMENT FL5259-R26.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2017-07-18 Cont ID  
Sent By jgomez Date 2017-07-18 Time 17:48 Rev Time 0.00
Received By jgomez Date 2017-07-18 Time 17:44 Sent To  
Notes
2017-07-18 17:48:521- ROOFING MATERIAL IS NOT CLEAR. MATERIALS AND COLOR
 INFORMATION ON SHEET SP-1 AND WEST ELEVATION ON SHEET
 A-4 CALL FOR SHINGLES TO MATCH EXISTING SHINGLES. BUT,
 PRODUCT APPROVAL FL7804-R9 SUBMITTED IS FOR CONCRETE
 ROOF TILE. PRODUCT APPROVAL AND SPECIFICATIONS NEED TO
 MATCH. SEC. 107.2.1 CITY AMENDMENTS. NOTE: IF USING
 CONCRETE TILE, THEN SPECIFY IF EXISTING HOUSE IS GOING
 TO RECEIVE CONCRETE TILE ALSO. AND, PROVIDE ENGINEERING
 ANALYSIS SHOWING THAT THE EXISTING STRUCTURE IS
 ADEQUATE TO RECEIVE THE ADDITIONAL CONCRETE TILE LOAD.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 2- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A) ROOF SHINGLES. NOTE: COORDINATE WITH ITEM ABOVE.
  
 B) ROOF UNDERLAYMENT. FLORIDA PRODUCT APPROVAL
 FL5259-R25 SUBMITTED WAS REVISED. PROVIDE 2 COPIES OF
 REVISED PRODUCT APPROVAL FL5259-R26 AND CLEARLY MARK
 WHICH SPECIFIC UNDERLAYMENT IS GOING TO BE USED.
  
 C) ROOF TILE ADHESIVE AS HIGHLIGHTED ON ROOF TILE
 PRODUCT APPROVAL SUBMITTED. NOTE: COORDINATE WITH ITEM
 #9 ABOVE.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2017-06-29 Cont ID  
Sent By fmittner Date 2017-06-29 Time 16:44 Rev Time 0.00
Received By fmittner Date 2017-06-29 Time 16:44 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved