Plan Review Stops For Permit 17060358 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-07-14 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-07-10 |
Time |
13:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-06-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-06-26 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-06-26 |
Time |
07:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2017-08-14 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-08-14 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-08-14 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2017-07-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-25 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-25 |
Time |
12:06 |
Sent To |
|
|
Notes |
2017-07-25 12:25:00 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | PREVIOUS COMMENT HAS NOT COMPLIED 2ND REQUEST 3. SUBMIT | | CALCULATIONS FOR COMBUSTION AIR PER THE FBC-2014 FUEL | | GAS CODE SEC. 304. | | | | THE RESPONSE TO THIS COMMENT IS INCORRECT THE SECTION | | OF THE FBC FG 505.2 DOES NOT EXIST AND SEC 505 DEALS | | WITH DIRECT-VENT AND INTEGRAL VENT APPLIANCES AND | | MECHANICAL VENTING SYSTEMS AND EXHAUST HOOD VENTING | | | | COMBUSTION AIR SHALL COMPLY WITH FBC FG 304.1 GENERAL. | | AIR FOR COMBUSTION, VENTILATION AND DILUTION OF FLUE | | GASES FOR APPLIANCES INSTALLED IN BUILDINGS SHALL BE | | PROVIDED BY APPLICATION OF ONE OF THE METHODS | | PRESCRIBED IN SECTIONS 304.5 THROUGH 304.9. WHERE THE | | REQUIREMENTS OF SECTION 304.5 ARE NOT MET, OUTDOOR AIR | | SHALL BE INTRODUCED IN ACCORDANCE WITH ONE OF THE | | METHODS PRESCRIBED IN SECTIONS 304.6 THROUGH 304.9. | | DIRECT-VENT APPLIANCES, GAS APPLIANCES OF OTHER THAN | | NATURAL DRAFT DESIGN AND VENTED GAS APPLIANCES OTHER | | THAN CATEGORY I SHALL BE PROVIDED WITH COMBUSTION, | | VENTILATION AND DILUTION AIR IN ACCORDANCE WITH THE | | APPLIANCE MANUFACTURER?S INSTRUCTIONS. | | | | THE ONLY EXCEPTION FOR COMBUSTION AIR IS FOR CLOTHES | | DRYERS | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-06-21 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-06-21 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-21 |
Time |
16:59 |
Sent To |
|
|
Notes |
2017-06-21 17:01:24 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | SEC. 502 THRU 505. | | | | 2. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | 3. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2017-06-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-06-14 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-06-14 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-08-17 |
Time |
|
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-08-10 |
Time |
14:37 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-07-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-25 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-19 |
Time |
09:28 |
Sent To |
|
|
Notes |
2017-07-21 09:28:32 | RESUB ROUTED TO GJOHNSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-07-17 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-06-08 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2017-07-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-25 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-25 |
Time |
12:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-07-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-07-14 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-07-14 |
Time |
09:58 |
Sent To |
|
|
Notes |
2017-07-14 10:59:51 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-08-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-17 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-08-17 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2017-07-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-07-17 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-07-17 |
Time |
07:38 |
Sent To |
|
|
Notes |
2017-07-17 08:15:20 | MECHANICAL PROVISOS | | 7/17/2017 | | | | 1) MANUFACTURER'S SPECIFICATIONS FOR THE GAS FIREPLACE, | | GAS RANGE AND EXHAUST HOOD SHALL BE ONSITE AT TIME OF | | ROUGH INSPECTION. | | | | 2) RELOCATE THE LOUVERED DOOR FOR AHU-1 TO AVOID RETURN | | AIR BEING TAKEN FROM THE KITCHEN. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-06-21 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-21 |
Time |
15:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-07-14 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-07-14 |
Time |
09:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-06-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-06-14 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-06-14 |
Time |
13:58 |
Sent To |
|
|
Notes |
2017-06-14 13:58:24 | DRIVEWAY UNDER SEPARATE PERMIT. SAHLL BE 3' OFF | | PROPERTY LINE. |
|
|