Plan Review Stops For Permit 17060265 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-12-19 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-12-19 |
Time |
12:55 |
Sent To |
|
|
Notes |
2017-12-19 12:57:45 | 12/19/17 MET WITH KEVIN. HE SAID TO PROCESS PERMIT WITH | | PROVISO. JG. | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- PROVIDE COMPLETE REVISED ENERGY CALCULATIONS REPORT. | | NOTE: COORDINATE WITH PLANS. | | 2- REVISE DOORS INFORMATION ON PAGE 3 OF 4 TO MATCH | | PLANS & PRODUCT APPROVALS. | | 3- COORDINATE COOLING AND HEATING INFORMATION TO MATCH | | EQUIPMENT SIZING CALCULATIONS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2017-12-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-12-15 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-12-15 |
Time |
16:16 |
Sent To |
|
|
Notes |
2017-12-15 16:17:25 | | | RESIDENTIAL (R3) ADDITION/ALTERATION 7TH BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE: ON PREVIOUS REVIEWS THE PROVISO OPTION WAS | | OFFERED. UNFORTUNATELY, RE-SUBMITTALS ARE RAISING MORE | | QUESTIONS THAN ANSWERS, THEREFORE DELAYING THE PERMIT | | PROCESS. | | | | ENERGY CALCULATIONS SUBMITTED: | | 1- ENERGY CALCULATIONS NEED TO BE CERTIFIED AT THE | | BOTTOM OF THE FORM BY THE OWNER OR LEGALLY DESIGNATED | | AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | 2- HEATING AND COOLING INFORMATION SHOWN ON THE REVISED | | ENERGY CALCULATIONS DOESN'T MATCH INFORMATION SHOWN ON | | THE EQUIPMENT SIZING CALCULATIONS SUBMITTED. | | RESPONSE: REPEAT COMMENT. REVISE AS REQUIRED TO MATCH. | | | | 3- ON PREVIOUS REVIEW IT WAS REQUESTED TO SUBMIT THE | | COMPLETE ENERGY CALCULATIONS REPORT BECAUSE THEY WERE | | REVISED AND ONLY SOME PAGES WERE SUBMITTED. REPORT | | SUBMITTED NOW IS MISMATCHING PAGES FROM OLD REPORTS | | WITH PAGES OF THE LATEST REVISED REPORT. SOME PAGES ARE | | DATED 12/5/17 AND SOME PAGES ARE DATED 10/25/17. WHEN | | THERE ARE CHANGES A COMPLETE REPORT RUN ON THE SAME | | DATED NEED TO BE GENERATED. MISMATCHING PAGES IS NOT | | ALLOWED BECAUSE ANY CHANGE AFFECTS THE OVERALL REPORT. | | NOTE: INFORMATION SHOWN ON PAGE 3 OF 4 DATED 10/25/17 | | IS INCORRECT. FOR EXAMPLE THE WINDOWS INFORMATION | | DOESN'T MATCH PLANS. PROVIDE COMPLETE ENERGY | | CALCULATIONS REPORT THAT MATCHES PLANS TO AVOID MORE | | DELAYS OR CONFLICTS. | | | | 4- DOORS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T MATCH | | PLANS. CLARIFY WHICH INSULATED DOORS ARE LOCATED EAST | | AND WEST. REVISE AS REQUIRED TO MATCH PLANS AND PRODUCT | | APPROVALS SUBMITTED. SEC. R101.5.1.1.2 FBC-ENERGY | | CONSERVATION. NOTE: ONLY THE DOORS THAT SEPARATE A/C | | SPACE FROM NON A/C SPACE ARE TO BE CONSIDERED. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2017-11-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-30 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-30 |
Time |
11:32 |
Sent To |
|
|
Notes |
2017-11-28 16:03:16 | RESIDENTIAL (R3) ADDITION/ALTERATION SIXTH BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO: PROVISO | | MEANS THAT CONTRACTOR MAY SUBMIT REQUIRED REVISED | | INFORMATION AFTER THE PERMIT IS ISSUED, BUT BEFORE ANY | | INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO | | ADVICE IF THE PROVISO OPTION IS PREFERRED AT THIS TIME. | | REVISION FEES APPLY IF INFORMATION IS SUBMITTED AFTER | | THE PERMIT IS ISSUED. | | | | NEW COMMENT: | | 1- EQUIPMENT SPECIFIED ON THE NEW ENERGY CALCULATIONS | | SUBMITTED DOESN'T MATCH EQUIPMENT SHOWN ON THE A/C PLAN | | SUBMITTED. EQUIPMENT SIZE AND MANUFACTURER DON'T MATCH. | | REVISE AS REQUIRED TO MATCH. SEC. R101.5.1.1.2 | | FBC-ENERGY CONSERVATION. | | NOTE: COORDINATE WITH EQUIPMENT CALCULATIONS REQUESTED | | ON THE MECHANICAL REVIEW. SEE MECHANICAL REVIEW | | COMMENTS. | | | | 2- NEW ENERGY CALCULATIONS FORM 405-2014 SUBMITTED: | | ORIGINAL COMMENT: | | A) PERSON PREPARING THE ENERGY CALCULATIONS IS TAKING | | THE "WHOLE HOUSE FAN OPTION". IN ORDER TO TAKE THIS | | CREDIT THE REQUIREMENTS OF SEC. R405.7.5 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014) MUST BE MET. | | ARCHITECTURAL PLANS DON'T SHOW ANY INFORMATION FOR | | WHOLE HOUSE FAN. PERSON PREPARING THE ENERGY | | CALCULATIONS TO PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW THESE REQUIREMENTS ARE MET. | | RESPONSE: | | IT LOOKS LIKE THE ENERGY CALCULATIONS WERE REVISED BUT | | THE ENERGY CALCULATIONS WERE NOT RESUBMITTED IN ITS | | ENTIRETY. ONLY A COUPLE OF PAGES WERE RESUBMITTED. | | SUBMIT 2 COPIES OF COMPLETE REVISED ENERGY | | CALCULATIONS. | | | | ORIGINAL COMMENT: | | B) DOORS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T MATCH | | PLANS. CLARIFY WHICH INSULATED DOORS ARE LOCATED EAST | | AND WEST. REVISE AS REQUIRED TO MATCH PLANS AND PRODUCT | | APPROVALS SUBMITTED. SEC. R101.5.1.1.2 FBC-ENERGY | | CONSERVATION. | | RESPONSE: | | CALCULATIONS WERE REVISED BUT THEY DON'T MATCH PLANS. | | WHICH 36"X80" INSULATED DOOR IS LOCATED IN THE SOUTH | | WALL?. AND, WHICH 26"X80" INSULATED DOOR IS LOCATED IN | | THE NORTH WALL?. NOTE: ONLY THE DOORS THAT SEPARATE A/C | | AREA FROM NON A/C AREA ARE THE ONES TO BE CONSIDERED. | | | | 2- TRUSS PACKAGE SUBMITTED; | | A) ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | TRUSS PACKAGE BEFORE SUBMITTAL TO THIS OFFICE. SEC. | | 107.3.4.2 CITY AMENDMENTS. | | RESPONSE: | | SHOP DRAWINGS REVIEW STAMP IS MISSING THE ARCHITECT'S | | INFORMATION. IT DOESN'T IDENTIFY WHO REVIEW THE TRUSS | | PACKAGE. PROVIDE SHOP DRAWINGS REVIEW STAMP THAT | | INCLUDES THE ARCHITECT'S INFORMATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2017-11-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-06 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-06 |
Time |
10:50 |
Sent To |
|
|
Notes |
2017-11-06 11:24:30 | RESIDENTIAL (R3) ADDITION/ALTERATION FIFTH BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO: PROVISO | | MEANS THAT CONTRACTOR MAY SUBMIT REQUIRED REVISED | | INFORMATION AFTER THE PERMIT IS ISSUED, BUT BEFORE ANY | | INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO | | ADVICE IF THE PROVISO OPTION IS PREFERRED AT THIS TIME. | | REVISION FEES APPLY. | | | | | | 1- NEW ENERGY CALCULATIONS FORM 405-2014 SUBMITTED: | | A) PERSON PREPARING THE ENERGY CALCULATIONS IS TAKING | | THE "WHOLE HOUSE FAN OPTION". IN ORDER TO TAKE THIS | | CREDIT THE REQUIREMENTS OF SEC. R405.7.5 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014) MUST BE MET. | | ARCHITECTURAL PLANS DON'T SHOW ANY INFORMATION FOR | | WHOLE HOUSE FAN. PERSON PREPARING THE ENERGY | | CALCULATIONS TO PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW THESE REQUIREMENTS ARE MET. | | NOTE: THIS INFORMATION IS ONLY REQUIRED WHEN THE ENERGY | | CALCULATIONS ARE TAKING ANY CREDITS ON ITEM #15. | | | | B) DOORS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T MATCH | | PLANS. CLARIFY WHICH INSULATED DOORS ARE LOCATED EAST | | AND WEST. REVISE AS REQUIRED TO MATCH PLANS AND PRODUCT | | APPROVALS SUBMITTED. SEC. R101.5.1.1.2 FBC-ENERGY | | CONSERVATION. | | | | C) WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T | | MATCH PLANS. REVISE AS REQUIRED. REVISE WINDOWS | | ORIENTATION AND SQUARE FOOTAGE TO MATCH PLANS AND | | PRODUCT APPROVALS SUBMITTED. SEC. R101.5.1.1.2 | | FBC-ENERGY CONSERVATION. | | NOTE: SEE SURVEY FOR CORRECT BUILDING ORIENTATION TO | | AVOID MORE CONFLICTS/DELAYS. | | | | 2- TYPICAL WALL SECTION @ FAMILY ROOM: PLANS WERE | | REVISED TO BUILD A NEW ROOF OVER THE PROPOSED FAMILY | | AREA ADDITION. SPECIFY ROOF VENTILATION AS REQUIRED BY | | SEC. R806 FBC-RESIDENTIAL, 5TH EDITION (2014). REVISED | | WALL SECTION IS MISSING THIS INFORMATION. SPECIFY VENT | | SIZE AND SPACING. | | | | 3- TRUSS PACKAGE SUBMITTED; | | A) MISSING THE TRUSS LAYOUT. NOTE: TRUSS LAYOUT AND | | ARCHITECT'S ROOF FRAMING PLAN NEED TO MATCH. SEC. | | R301.1 FBC-RESIDENTIAL. PROVIDE TRUSS LAYOUT. | | | | B) ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | TRUSS PACKAGE BEFORE SUBMITTAL TO THIS OFFICE. SEC. | | 107.3.4.2 CITY AMENDMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2017-10-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-03 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-02 |
Time |
10:37 |
Sent To |
|
|
Notes |
2017-10-02 11:31:59 | RESIDENTIAL (R3) ADDITION/ALTERATION FOURTH BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO: PROVISO | | MEANS THAT CONTRACTOR MAY SUBMIT REQUIRED REVISED | | INFORMATION AFTER THE PERMIT IS ISSUED, BUT BEFORE ANY | | INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO | | ADVICE IF THE PROVISO OPTION IS PREFERRED AT THIS TIME. | | REVISION FEES APPLY. SIGN ENERGY CALCULATIONS. | | | | | | 1- DIFFERENT ENERGY CALCULATIONS PRESCRIPTIVE FORM | | R402-2014 SUBMITTED: | | NOTE: PRESCRIPTIVE METHOD IS MORE STRICT THAN THE | | PREVIOUS FORM R405-2014 SUBMITTED. NEED TO COMPLY WITH | | ALL THE REQUIREMENTS OF TABLE R402A. THE FOLLOWING | | CONDITIONS NEED TO BE MET: | | A) THE PRESCRIPTIVE FORM R402-2014 CAN NOT BE USED IF | | THE AIR HANDLER UNIT IS LOCATED IN THE ATTIC. SEE AIR | | DISTRIBUTION INFORMATION ON TABLE R402A OF FORM | | SUBMITTED. ACCORDING TO PLANS SUBMITTED, IT LOOKS LIKE | | THE AIR HANDLER IS LOCATED IN THE ATTIC OF THE MAIN | | HOUSE. CLEARLY IDENTIFY LOCATION OF AIR HANDLER UNIT. | | | | B) THE CONDITIONED FLOOR AREA SHOWN ON ITEM #5 NEEDS TO | | BE REVISED. THE PROPOSED ADDITION IS 19'-9" X 12'-5". | | THEREFORE THE CORRECT AREA IS =/- 245 S.F. NOT 208 S.F. | | NOTE: ARCHITECTURAL PLANS NEED TO BE REVISED ALSO. | | | | C) THE WINDOWS U-FACTOR AND SHGC FACTOR SHOWN ON ITEM | | #6 DON'T COMPLY WITH THE MIN. REQUIRED FACTORS SHOWN ON | | TABLE R402A. SEE GENERAL INSTRUCTION #1 ON FRONT PAGE | | OF FORM SUBMITTED AND REVISE AS REQUIRED. AND, PROVIDE | | WINDOW AND DOORS MANUFACTURER'S SPECS SHOWING THAT THE | | PROPOSED WINDOWS MEET THE REQUIRED FACTORS. | | | | D) THE CONCRETE BLOCK WALL INFORMATION SHOWN ON ITEM | | #9(A)(2). CONCRETE BLOCK WALLS NEED TO HAVE INSULATION | | ON THE INTERIOR AND EXTERIOR SIDE OF THE WALL AS | | REQUIRED BY TABLE R402A . SEE NOTE #4 OF TABLE R402A. | | PLANS DON'T SHOW ANY INSULATION ON THE INTERIOR AND | | EXTERIOR SIDE OF THE WALL. PERSON PREPARING THE ENERGY | | CALCULATIONS TO PROVIDE COMPLETE DOCUMENTATION SHOWING | | COMPLIANCE WITH THIS REQUIREMENT. SEC. R103.2 | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). REVISE AS | | REQUIRED. | | | | E) THE CEILING INFORMATION ON ITEM 10 DOESN'T COMPLY | | WITH TABLE R402A. THIS IS A SINGLE ASSEMBLY CEILING, | | THERE IS NOT ATTIC AND THE MINIMUM CEILING INSULATION | | REQUIRED BY TABLE R402A IS R-30. ALSO, ACCORDING TO | | ARCHITECTURAL PLANS THE CEILING JOISTS ARE 2X6. IT | | DOESN'T SEEM TO BE ENOUGH ROOM FOR THE R-30 INSULATION. | | PROVIDE COMPLETE DETAILS L AND SPECIFICATIONS SHOWING | | HOW INSTALLING R-30 INSULATION ON A 2X6 ROOF JOIST?. | | SEC. R1074.2.1 CITY AMENDMENTS. ALSO, COORDINATE | | CEILING AREA WITH ITEM #1(B) ABOVE. | | | | F) NEED TO COMPLETE THE MANDATORY REQUIREMENTS OF TABLE | | R402B AS REQUIRED BY NOTE #3 OF THE GENERAL | | INSTRUCTIONS OF FORM R402-2014 SUBMITTED. | | | | G) OWNER OR LEGALLY DESIGNATED AGENT NEED TO CERTIFY | | AND DATE AT THE BOTTOM OF THE ENERGY CALCULATIONS | | SUBMITTED AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | RESPONSE: REPEAT COMMENT. NEW FORM SUBMITTED WAS NOT | | CERTIFIED AT THE BOTTOM OF THE FORM BY THE OWNER. | | PERMIT CAN NOT BE ISSUED WITHOUT THE OWNER'S | | CERTIFICATION. | | | | NOTE: | | LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND | | SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS IS | | REQUIRED WHEN CALCULATIONS ARE NO USING THE DEFAULT | | FACTORS. | | | | | | 2- THE "NEW PORCH ENCLOSURE" CONDITIONED FLOOR AREA | | SHOWN ON THE AREA CALCULATIONS NEEDS TO BE REVISED. THE | | PROPOSED "PORCH ENCLOSURE" ADDITION IS 19'-9" X 12'-5". | | THEREFORE THE CORRECT AREA IS =/- 245 S.F. NOT 208 S.F. | | NOTE: ARCHITECTURAL PLANS NEED TO BE REVISED. SEC. | | 107.2.1 CITY AMENDMENTS. | | | | 3- TYPICAL WALL SECTION @ FAMILY ROOM: | | A) SPECIFY CEILING INSULATION. SEC. R103.2 FBC-ENERGY | | CONSERVATION. NOTE: KEEP IN MIND SIZE OF EXISTING ROOF | | JOISTS (2X6). SPECIFY INSULATION TYPE AND R-VALUE. | | ALSO, WALL SECTION SPECIFIES "EXISTING VENTED SOFFIT". | | KEEP IN MIND THE CLEARANCE REQUIRED BETWEEN THE | | INSULATION AND UNDERSIDE OF ROOF SHEATHING FOR CROSS | | VENTILATION AS REQUIRED BY SEC. R806.3 FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | (REPEAT COMMENT). | | | | B) SPECIFY R-VALUE FOR CONCRETE BLOCK WALL INSULATION. | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | (REPEAT COMMENT). | | | | C) PROVIDE SPECIFICATIONS FOR NEW CEILING FINISH THAT | | IS COVERING THE INSULATION. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | NOTE: | | ARCHITECT MAY BE CHARGED FOUR TIMES THE PLAN REVIEW | | FEES FOR MULTIPLE REJECTIONS AS REQUIRED BY FLORIDA | | STATUTE 553.80(2)(B) | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-08-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-08-28 |
Time |
18:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-08-28 |
Time |
09:19 |
Sent To |
|
|
Notes |
2017-08-28 09:24:41 | RESIDENTIAL (R3) ADDITION/ALTERATION THIRD BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- ENERGY CALCULATIONS SUBMITTED (NOTE: ENERGY | | CALCULATIONS AND PLANS NEED TO BE COORDINATED TO AVOID | | CONFLICT/DELAYS): | | A) OWNER OR LEGALLY DESIGNATED AGENT NEED TO CERTIFY | | AND DATE AT THE BOTTOM OF THE ENERGY CALCULATIONS | | SUBMITTED AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | | | B) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | (EPL) DISPLAY CARD SUBMITTED AS REQUIRED BY SEC. | | R103.1.1.2 FBC-ENERGY CONSERVATION. | | | | C) PLANS SUBMITTED DON'T SHOW ANY INFORMATION FOR THE | | R-30 CEILING INSULATION (SPECIALLY ON THE FLAT ROOF OF | | THE FAMILY AREA ADDITION) AND WALLS. PERSON PREPARING | | THE ENERGY CALCULATIONS TO CLARIFY WHERE IS THIS | | INFORMATION TAKEN FROM. NOTE: R-30 INSULATION MAY NOT | | FIT IN THE FLAT ROOF OF THE NEW ADDITION. ALSO, PLANS | | SUBMITTED DON'T SHOW ANY OVERHANG ON THE FLAT ROOF. | | COORDINATE WITH ARCHITECT OF RECORD TO AVOID | | CONFLICT/DELAYS AND REVISE AS REQUIRED. SEC. R103.2.1 | | FBC-ENERGY CONSERVATION. | | | | D) PLANS SUBMITTED DON'T SHOW ANY INFORMATION FOR THE | | CEILING VENTILATION ON THE FAMILY ADDITION AND GARAGE | | ENCLOSURE. PERSON PREPARING THE ENERGY CALCULATIONS TO | | CLARIFY WHERE IS THIS INFORMATION TAKEN FROM. ALSO, | | PLANS SUBMITTED DON'T SHOW ANY OVERHANG ON THE FLAT | | ROOF. COORDINATE WITH ARCHITECT OF RECORD TO AVOID | | CONFLICT/DELAYS AND REVISE AS REQUIRED. SEC. R103.2.1 | | FBC-ENERGY CONSERVATION. | | | | E) REVISE THE ROOF TYPE ON PAGE 2 OF 4. THE ROOF TYPE | | IS GABLE NOT HIP. REVISE THE GABLE AREA AS WELL. SEC. | | R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | F) DOORS INFORMATION ON PAGE 3 OF 4 SPECIFY 3 INSULATED | | DOORS. COORDINATE WITH PLANS AND PRODUCT APPROVALS AND | | REVISE AS REQUIRED. NOTE: OVERHEAD GARAGE DOORS ARE NO | | TO BE CONSIDERED. DOORS TO BE BE CONSIDERED ARE THOSE | | THAT SEPARATE A/C SPACE FROM NON-A/C SPACE. REVISE AS | | REQUIRED. | | | | NOTE: | | LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND | | SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS IS | | REQUIRED WHEN CALCULATIONS ARE NO USING THE DEFAULT | | FACTORS. | | | | 2- PLANS SUBMITTED NEED TO HAVE ARCHITECT'S ORIGINAL | | SEAL AND SIGNATURE. PERMIT APPLICATION AND PLANS | | SUBMITTED ARE HARD COPIES NOT DIGITAL SUBMITTAL. PLANS | | SUBMITTED SHOW A DIGITAL SIGNATURE. THIS IS NOT ALLOWED | | ON HARD COPIES SUBMITTAL. SEC. 481.221 F.S. | | | | 3- PROVIDE COMPLETE WALL SECTION THRU THE NEW FAMILY | | ROOM ADDITION AND THRU THE NEW GARAGE ENCLOSURE. | | SPECIFY ALL THE STRUCTURAL CONNECTIONS SHOWING | | COMPLIANCE WITH THE LOAD PATH AS REQUIRED BY SEC. | | R801.2, R601.2 AND R401.2 FBC-RESIDENTIAL. | | RESPONSE. CLEARLY SPECIFY TYPE AND SIZE OF SIMPSON MTS | | STRAP. SPECIFIED STRAP IS A WOOD TO WOOD CONNECTOR. | | PROPOSED CONSTRUCTION LOOKS LIKE WOOD TO CONCRETE | | BLOCK. SPECIFY SPACING OF STRAPS FROM WOOD BEAM TO | | CONCRETE BLOCK BEAM. REVISE/CLARIFY DETAIL AS REQUIRED. | | | | 4- PROVIDE COMPLETE ROOF FRAMING PLAN FOR THE FAMILY | | ROOM ADDITION. SEC. R301.1 FBC-RESIDENTIAL. SPECIFY ALL | | FRAMING MEMBERS SIZES AND CONNECTORS. | | RESPONSE. REPEAT COMMENT. THERE IS NO INFORMATION ABOUT | | THE ROOF FRAMING SYSTEM AND CONNECTORS. SPECIFY FRAMING | | MEMBERS SIZING, SPACING AND CONNECTORS TO VERIFY | | COMPLIANCE WITH THE CURRENT WIND LOADS. NOTE: THIS AREA | | WAS AN ENCLOSED PORCH. NOW IS PROPOSED TO BE LIVABLE | | AREA. THAT'S WHY THE STRUCTURE NEEDS TO COMPLY WITH | | CURRENT WIND LOADS. | | | | 5- ENERGY CALCULATIONS SUBMITTED CALL FOR R-30 CEILING | | INSULATION. PLANS NEED TO PROVIDE SPECIFICATIONS FOR | | THE CEILING AND WALLS INSULATION AS REQUIRED BY SEC. | | R103.1.1.2 FBC-ENERGY CONSERVATION. NOTE: KEEP IN MIND | | THAT R-30 BUTT INSULATION IS ABOUT 9-1/2" THICK. SIZE | | OF ROOF FRAMING MEMBERS MAY NOT ALLOW R-30 INSULATION | | AND CROSS VENTILATION (IF VENTILATION IS SPECIFIED BY | | THE ARCHITECT). COORDINATE WITH ITEM #4, ITEM #1(C) AND | | #1(D) ABOVE. | | | | 6- SPECIFY ROOF VENTILATION FOR THE FAMILY ROOM | | ADDITION AND GARAGE ENCLOSURE. SEC. R806.1 | | FBC-RESIDENTIAL. | | RESPONSE. REPEAT COMMENT. ENERGY CALCULATIONS AND PLANS | | NEED TO BE COORDINATED TO AVOID CONFLICTS/DELAYS. | | COORDINATE WITH ITEM #1(C) AND #1(D) ABOVE. | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | PLANS. PROVIDE THE FLORIDA PRODUCT APPROVAL COVER PAGE | | THAT CORRESPONDS TO REPORT SUBMITTED. OR ARCHITECT TO | | LIST THE CURRENT FLORIDA PRODUCT APPROVAL NUMBER NEXT | | TO EACH SPECIFIED CONNECTOR. | | | | 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL THE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | RESPONSE. | | A) ARCHITECT'S LETTER SUBMITTED IS TOO GENERAL. IF | | USING A LETTER AS A RESPONSE FOR THE REVIEW OF EACH | | PRODUCT APPROVAL, THEN CLEARLY IDENTIFY EACH PRODUCT | | APPROVAL BY MANUFACTURER'S NAME AND SPECIFIC NOA OR | | FLORIDA PRODUCT APPROVAL NUMBER. | | | | B) LETTER SUBMITTED NEEDS ARCHITECT'S ORIGINAL SEAL AND | | SIGNATURE. PERMIT APPLICATION AND PLANS SUBMITTED ARE | | HARD COPIES NOT DIGITAL SUBMITTAL. LETTER SUBMITTED | | SHOW A DIGITAL SIGNATURE. THIS IS NOT ALLOWED ON HARD | | COPIES SUBMITTAL. SEC. 481.221 F.S. | | | | 9- NEW GARAGE DOOR PRODUCT APPROVAL SUBMITTED REQUIRES | | 4.000 PSI MINIMUM CONCRETE JAMB. SEE NOA 14-0822.06 | | SUBMITTED. REVISE GARAGE DOOR JAMB DETAILS AND | | SPECIFICATIONS ON THE FLOOR PLAN AND DETAILS AS | | REQUIRED BY THE NOA SUBMITTED. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-07-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-17 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-07-17 |
Time |
11:27 |
Sent To |
|
|
Notes |
2017-07-17 11:29:43 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 3- PLANS SUBMITTED ARE MISSING SHEET 2 OF 2. SEC. | | 107.2.1 CITY AMENDMENTS. PROVIDE COMPLETE SET OF PLANS. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 4- SPECIFY CARBON MONOXIDE ALARMS BY ALL THE BEDROOMS | | AS REQUIRED BY SEC. R315.1 FBC-RESIDENTIAL, 5TH EDITION | | (2014). | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 5- OPENING BETWEEN EXISTING BATHROOM AND PROPOSED | | GARAGE NEEDS TO COMPLY WITH THE OPENING PROTECTION AS | | REQUIRED BY SEC. R302.5.1 FBC-RESIDENTIAL. REVISE PLANS | | SHOWING COMPLIANCE. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 6- PROVIDE SPECIFICATIONS FOR THE GARAGE DOOR FIRE | | SPECIFICATIONS AND SELF CLOSING DEVICE AS REQUIRED BY | | SEC. R302.5.1 FBC-RESIDENTIAL. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 7- EXISTING BATHROOM ADJACENT TO THE PROPOSED GARAGE | | NEEDS TO COMPLY WITH THE VENTILATION REQUIREMENTS OF | | SEC. R303.3 FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS FOR | | THE VENTILATION. NOTE: COORDINATE WITH ITEM # 5 ABOVE. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 8- PROVIDE COMPLETE WALL SECTION THRU THE NEW FAMILY | | ROOM ADDITION AND THRU THE NEW GARAGE ENCLOSURE. | | SPECIFY ALL THE STRUCTURAL CONNECTIONS SHOWING | | COMPLIANCE WITH THE LOAD PATH AS REQUIRED BY SEC. | | R801.2, R601.2 AND R401.2 FBC-RESIDENTIAL. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 9- PROVIDE FOUNDATION PLAN FOR NEW FAMILY ROOM ADDITION | | AND PROPOSED GARAGE. SEC. R301.1 FBC-RESIDENTIAL. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 10- PROVIDE COMPLETE ROOF FRAMING PLAN FOR THE FAMILY | | ROOM ADDITION. SEC. R301.1 FBC-RESIDENTIAL. SPECIFY ALL | | FRAMING MEMBERS SIZES AND CONNECTORS. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 11- SPECIFY ROOF VENTILATION FOR THE FAMILY ROOM | | ADDITION. SEC. R806.1 FBC-RESIDENTIAL. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 12- PROVIDE OVERHEAD GARAGE DOOR STRUCTURAL BUCK | | DETAIL. SEC. R301.1 FBC-RESIDENTIAL. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 13- PROVIDE STRUCTURAL BUCK DETAIL FOR NEW FRENCH DOORS | | AND WINDOWS. SEC. R612..7.2.1 FBC-RESIDENTIAL. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 14- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) WINDOW MULLIONS AS SPECIFIED ON PLANS. NOTE: | | ARCHITECT OF RECORD TO SPECIFY MULLION SIZE TO BE USED | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | R301.1 FBC-RESIDENTIAL. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | B) PRECAST LINTELS AS SPECIFIED ON PLANS. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | C) ALL SIMPSON (OR ANY OTHER STRUCTURAL CONNECTOR) | | STRUCTURAL CONNECTORS SPECIFIED ON PLANS. PROVIDE ONLY | | THE FLORIDA PRODUCT APPROVAL COVER PAGE AND PAGE | | SHOWING THE SPECIFIED CONNECTOR. OR ARCHITECT TO LIST | | THE CURRENT FLORIDA PRODUCT APPROVAL NUMBER NEXT TO | | EACH SPECIFIED CONNECTOR. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | D) NEW OVERHEAD GARAGE DOOR THAT MEETS THE SIZE | | SPECIFIED ON PLANS. NOA 15-0225.06 SUBMITTED IS FOR | | GARAGE DOORS UP TO 9'-0" WIDE. SIZE OF DOOR SPECIFIED | | ON PLANS IS WIDER. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 15- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN | | WRITING (NOT SIGNING AND SEALING) ALL THE PRODUCT | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | 16- PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR THE | | NEW OPENING AND FRAMING FOR RELOCATED DOOR BETWEEN THE | | GARAGE AND KITCHEN AREA. SEC. R301.1 FBC-RESIDENTIAL. | | AND PROVIDE DETAIL./SPECS FOR CLOSING THE EXISTING DOOR | | OPENING. | | RESPONSE. REPEAT COMMENT. NOT ADDRESSED. | | | | *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-07-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-10 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-07-10 |
Time |
09:16 |
Sent To |
|
|
Notes |
2017-07-10 09:18:29 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | 3- PLANS SUBMITTED ARE MISSING SHEET 2 OF 2. SEC. | | 107.2.1 CITY AMENDMENTS. PROVIDE COMPLETE SET OF PLANS. | | | | 4- SPECIFY CARBON MONOXIDE ALARMS BY ALL THE BEDROOMS | | AS REQUIRED BY SEC. R315.1 FBC-RESIDENTIAL, 5TH EDITION | | (2014). | | | | 5- OPENING BETWEEN EXISTING BATHROOM AND PROPOSED | | GARAGE NEEDS TO COMPLY WITH THE OPENING PROTECTION AS | | REQUIRED BY SEC. R302.5.1 FBC-RESIDENTIAL. REVISE PLANS | | SHOWING COMPLIANCE. | | | | 6- PROVIDE SPECIFICATIONS FOR THE GARAGE DOOR FIRE | | SPECIFICATIONS AND SELF CLOSING DEVICE AS REQUIRED BY | | SEC. R302.5.1 FBC-RESIDENTIAL. | | | | 7- EXISTING BATHROOM ADJACENT TO THE PROPOSED GARAGE | | NEEDS TO COMPLY WITH THE LIGHT AND VENTILATION | | REQUIREMENTS OF SEC. R303.3 FBC-RESIDENTIAL. PROVIDE | | SPECIFICATIONS FOR THE LIGHT AND VENTILATION. NOTE: | | COORDINATE WITH ITEM # 5 ABOVE. | | | | 8- PROVIDE COMPLETE WALL SECTION THRU THE NEW FAMILY | | ROOM ADDITION AND THRU THE NEW GARAGE ENCLOSURE. | | SPECIFY ALL THE STRUCTURAL CONNECTIONS SHOWING | | COMPLIANCE WITH THE LOAD PATH AS REQUIRED BY SEC. | | R801.2, R601.2 AND R401.2 FBC-RESIDENTIAL. | | | | 9- PROVIDE FOUNDATION PLAN FOR NEW FAMILY ROOM ADDITION | | AND PROPOSED GARAGE. SEC. R301.1 FBC-RESIDENTIAL. | | | | 10- PROVIDE COMPLETE ROOF FRAMING PLAN FOR THE FAMILY | | ROOM ADDITION. SEC. R301.1 FBC-RESIDENTIAL. SPECIFY ALL | | FRAMING MEMBERS SIZES AND CONNECTORS. | | | | 11- SPECIFY ROOF VENTILATION FOR THE FAMILY ROOM | | ADDITION. SEC. R806.1 FBC-RESIDENTIAL. | | | | 12- PROVIDE OVERHEAD GARAGE DOOR STRUCTURAL BUCK | | DETAIL. SEC. R301.1 FBC-RESIDENTIAL. | | | | 13- PROVIDE STRUCTURAL BUCK DETAIL FOR NEW FRENCH DOORS | | AND WINDOWS. SEC. R612..7.2.1 FBC-RESIDENTIAL. | | | | 14- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) WINDOW MULLIONS AS SPECIFIED ON PLANS. NOTE: | | ARCHITECT OF RECORD TO SPECIFY MULLION SIZE TO BE USED | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | R301.1 FBC-RESIDENTIAL. | | | | B) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | C) ALL SIMPSON (OR ANY OTHER STRUCTURAL CONNECTOR) | | STRUCTURAL CONNECTORS SPECIFIED ON PLANS. PROVIDE ONLY | | THE FLORIDA PRODUCT APPROVAL COVER PAGE AND PAGE | | SHOWING THE SPECIFIED CONNECTOR. OR ARCHITECT TO LIST | | THE CURRENT FLORIDA PRODUCT APPROVAL NUMBER NEXT TO | | EACH SPECIFIED CONNECTOR. | | | | D) NEW OVERHEAD GARAGE DOOR THAT MEETS THE SIZE | | SPECIFIED ON PLANS. NOA 15-0225.06 SUBMITTED IS FOR | | GARAGE DOORS UP TO 9'-0" WIDE. SIZE OF DOOR SPECIFIED | | ON PLANS IS WIDER. | | | | 15- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN | | WRITING (NOT SIGNING AND SEALING) ALL THE PRODUCT | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | | | 16- PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR THE | | NEW OPENING AND FRAMING FOR RELOCATED DOOR BETWEEN THE | | GARAGE AND KITCHEN AREA. SEC. R301.1 FBC-RESIDENTIAL. | | AND PROVIDE DETAIL./SPECS FOR CLOSING THE EXISTING DOOR | | OPENING. | | | | *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2017-12-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-12-05 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-12-05 |
Time |
12:26 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-11-13 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-11-13 |
Time |
08:35 |
Sent To |
|
|
Notes |
2017-11-13 08:49:25 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | GARAGE DOES NOT SHOW ANY OUTLETS. CODE STATES: "AT | | LEAST ONE RECEPTACLE OUTLET, IN ADDITION TO THOSE FOR | | SPECIFIC EQUIPMENT, SHALL BE INSTALLED IN EACH | | BASEMENT, IN EACH ATTACHED GARAGE, AND IN EACH DETACHED | | GARAGE OR ACCESSORY BUILDING WITH ELECTRIC POWER". | | PROVIDE OUTLET. NEC 210.52(G); FBC RE3901.9 | | | | PROVIDE GFCI PROTECTION FOR ALL OUTLETS IN GARAGE. NEC | | 210.8; FBC RE3902.2 | | | | PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER | | CODE. FBC R314.3, 315.1; FBC 107.2.1 | | | | PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF EACH | | ROOM USED FOR SLEEPING PURPOSES. FBC R315.1 | | | | | | SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | INSTALLED | | SO THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR | | LINE OF ANY WALL SPACE IS MORE THAN 6 FEET FROM A | | RECEPTACLE OUTLET. PROVIDE CORRECTION. NEC 210.52; FBC | | RE3901.2.1 | | | | THE WALL SPACING REQUIREMENTS FOR KITCHEN COUNTER SPACE | | STATE THAT RECEPTACLE OUTLETS SHALL BE INSTALLED | | SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24 | | INCHES MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET | | IN THAT SPACE. THE PLAN PROVIDED DOES NOT MEET THIS | | CODE IN SOME AREAS. PROVIDE CORRECTION. NEC | | 210.52(C)(1); | | FBC RE3901.4 | | | | E3903.2 HABITABLE ROOMS. AT LEAST ONE WALL | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED IN | | EVERY HABITABLE | | ROOM AND BATHROOM. [210.70(A)(1)] GARAGE AND NEW PORCH | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2017-10-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-10-04 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-10-04 |
Time |
16:09 |
Sent To |
Z |
|
Notes |
2017-10-04 16:10:35 | SEE REVIEW #2 FOR NOTES JLEAHY | 2017-10-03 15:24:15 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-09-06 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-09-06 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-09-06 |
Time |
11:00 |
Sent To |
|
|
Notes |
2017-09-06 11:04:09 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NEED RISER DIAGRAM, LOAD CALCULATION. | | | | OUTLET AND LIGHTING OUTLETS NOT PER ARTICLE 210 | 2017-08-28 09:25:14 | REVISED DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-06-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-06-23 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-06-23 |
Time |
14:13 |
Sent To |
|
|
Notes |
2017-06-23 14:37:16 | NEED RISER DIAGRAM | | | | LOAD CALCULATION | | | | PANEL SCHEDULE BEFORE FINAL ELECTRICAL INSPECTION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-12-19 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-12-19 |
Time |
12:54 |
Sent To |
|
|
Notes |
2017-12-19 12:55:18 | MET WITH KEVIN. HE SAID TO PROCESS PERMIT WITH PROVISO. | | JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2017-12-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-12-15 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-12-12 |
Time |
15:44 |
Sent To |
I |
|
Notes |
2017-12-13 15:44:57 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-12-12 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-11-17 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-11-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-11-13 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-10-26 |
Time |
13:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-10-05 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-09-19 |
Time |
18:55 |
Sent To |
|
|
Notes |
2017-10-02 11:23:47 | R12 | 2017-09-19 18:55:27 | JGOMEZ'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-09-06 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-09-06 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-08-23 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-07-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-17 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-07-10 |
Time |
10:27 |
Sent To |
|
|
Notes |
2017-07-12 10:28:02 | RESUB ROUTED TO AWOOTEN VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-07-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-10 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-06-07 |
Time |
13:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2017-08-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-08-28 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-08-28 |
Time |
10:33 |
Sent To |
|
|
Notes |
2017-08-28 10:34:03 | NO FEES DUE. MU-2017-20578. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2017-07-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-17 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-07-17 |
Time |
11:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-07-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-10 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-07-10 |
Time |
07:53 |
Sent To |
|
|
Notes |
2017-07-10 09:18:47 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
|
Date |
2018-01-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-01-19 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-19 |
Time |
09:24 |
Sent To |
|
|
Notes |
2018-01-19 09:32:09 | 01/19/18 | | PRELIMINARY REVIEW DONE FOR JOE (ASTRO AIR INC) FOR A/C | | PERMIT (E-MAIL RECEIVED ON 01/18/18) | | -2014 FORM NOT 2017 | | -CORRECT BUILDER NAME NOT THE A/C | | --NAME OF PREPARER AND SIGNATURE OF OWNER A THE BOTTOM | | OF PAGE ONE. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
N |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-12-19 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-12-19 |
Time |
17:18 |
Sent To |
|
|
Notes |
2017-12-19 17:20:36 | 12/19/17 MET WITH KEVIN. HE SAID TO PROCESS PERMIT WITH | | MECHANICAL UNDER A SEPARATE PERMIT. JG. | | | | | | | | 1) PROVIDE COMPLETE A/C PLANS AND EQUIPMENT SIZING | | CALCULATIONS UNDER A SEPARATE PERMIT. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2017-12-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-12-15 |
Time |
18:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-12-15 |
Time |
18:03 |
Sent To |
|
|
Notes |
2017-12-15 18:06:25 | RESIDENTIAL (R3) ADDITION/ALTERATION FIFTH MECHANICAL | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE: ON PREVIOUS REVIEWS THE PROVISO OPTION WAS | | OFFERED. UNFORTUNATELY, RE-SUBMITTALS ARE RAISING MORE | | QUESTIONS THAN ANSWERS, THEREFORE DELAYING THE PERMIT | | PROCESS. | | | | 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED | | ON THE BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION | | OF THE BUILDING AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY | | CONSERVATION. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | 2- ARCHITECT OF RECORD TO SIGN AND SEAL BOTH A/C PLANS | | SUBMITTED AS REQUIRED BY CHAPTER 481 FLORIDA STATUTE | | WHEN SUBMITTING PLANS FOR PUBLIC RECORDS. NOTE: ONLY | | ONE COPY WAS SIGNED AT THIS TIME. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | NOTE: CONTRACTOR MAY PROVIDE COMPLETE INFORMATION UNDER | | A SEPARATE MECHANICAL PERMIT. ADVICE IF THIS OPTION IS | | PREFERRED AT HIS TIME. | | | | | | *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2017-11-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-30 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-30 |
Time |
11:48 |
Sent To |
|
|
Notes |
2017-11-29 08:01:56 | RESIDENTIAL (R3) ADDITION/ALTERATION FOURTH MECHANICAL | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE: | | MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO: PROVISO | | MEANS THAT CONTRACTOR MAY SUBMIT REQUIRED REVISED | | INFORMATION AFTER THE PERMIT IS ISSUED, BUT BEFORE ANY | | INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO | | ADVICE IF THE PROVISO OPTION IS PREFERRED AT THIS TIME. | | REVISION FEES APPLY IF INFORMATION IS SUBMITTED AFTER | | THE PERMIT IS ISSUED. | | | | NEW COMMENT: | | 1- A) EQUIPMENT SIZE SPECIFIED ON THE A/C PLAN | | SUBMITTED DOESN'T MATCH EQUIPMENT SIZE SPECIFIED ON THE | | ENERGY CALCULATIONS SUBMITTED. REVISE AS REQUIRED TO | | MATCH. SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. | | | | B) EQUIPMENT SPECIFIED ON THE A/C PLAN SUBMITTED | | DOESN'T MATCH EQUIPMENT SPECIFIED ON THE EQUIPMENT | | SIZING CALCULATIONS SUBMITTED. REVISE AS REQUIRED TO | | MATCH. SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED | | ON THE BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION | | OF THE BUILDING AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY | | CONSERVATION. | | | | | | 3- ARCHITECT OF RECORD TO SIGN AND SEAL BOTH A/C PLANS | | SUBMITTED AS REQUIRED BY CHAPTER 481 FLORIDA STATUTE | | WHEN SUBMITTING PLANS FOR PUBLIC RECORDS. NOTE: ONLY | | ONE COPY WAS SIGNED AT THIS TIME. | | | | | | NOTE: CONTRACTOR MAY PROVIDE COMPLETE INFORMATION UNDER | | A SEPARATE MECHANICAL PERMIT. ADVICE IF THIS OPTION IS | | PREFERRED AT HIS TIME. | | | | | | *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-11-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-06 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-06 |
Time |
16:10 |
Sent To |
|
|
Notes |
2017-11-06 16:12:05 | RESIDENTIAL (R3) ADDITION/ALTERATION THIRD MECHANICAL | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PLANS SUBMITTED DON'T SHOW ANY MECHANICAL WORK, BUT | | A/C EQUIPMENT SIZING CALCULATIONS WERE SUBMITTED WITH | | THE ENERGY CALCULATIONS. CLARIFY IF DOING ANY | | MECHANICAL WORK. PROVIDE COMPLETE PLANS AND COMPLETE | | EQUIPMENT SIZING CALCULATIONS IF DOING ANY MECHANICAL | | WORK. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | NOTE: CONTRACTOR MAY PROVIDE COMPLETE INFORMATION UNDER | | A SEPARATE MECHANICAL PERMIT. ADVICE IF THIS OPTION IS | | PREFERRED AT HIS TIME. | | | | *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-10-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-03 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-03 |
Time |
15:29 |
Sent To |
|
|
Notes |
2017-10-03 15:32:01 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND MECHANICAL | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PLANS SUBMITTED DON'T SHOW ANY MECHANICAL WORK, BUT | | A/C EQUIPMENT SIZING CALCULATIONS WERE SUBMITTED WITH | | THE ENERGY CALCULATIONS. CLARIFY IF DOING ANY | | MECHANICAL WORK. PROVIDE COMPLETE PLANS AND COMPLETE | | EQUIPMENT SIZING CALCULATIONS IF DOING ANY MECHANICAL | | WORK. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | NOTE: CONTRACTOR MAY PROVIDE COMPLETE INFORMATION UNDER | | A SEPARATE MECHANICAL PERMIT. ADVICE IF THIS OPTION IS | | PREFERRED AT HIS TIME. | | | | *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-08-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-08-28 |
Time |
18:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-08-28 |
Time |
18:57 |
Sent To |
|
|
Notes |
2017-08-28 19:01:51 | RESIDENTIAL (R3) ADDITION/ALTERATION MECHANICAL REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PLANS SUBMITTED DON'T SHOW ANY MECHANICAL WORK, BUT | | A/C EQUIPMENT SIZING CALCULATIONS WERE SUBMITTED WITH | | THE ENERGY CALCULATIONS. CLARIFY IF DOING ANY | | MECHANICAL WORK. PROVIDE COMPLETE PLANS AND COMPLETE | | EQUIPMENT SIZING CALCULATIONS IF DOING ANY MECHANICAL | | WORK. | | | | *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2017-11-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-30 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-30 |
Time |
12:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2017-11-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-06 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-06 |
Time |
16:09 |
Sent To |
|
|
Notes |
2017-11-06 11:44:18 | NEW PLANS SUBMITTED. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-10-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-03 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-03 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-08-28 |
Time |
18:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-08-28 |
Time |
18:56 |
Sent To |
|
|
Notes |
2017-08-28 09:25:41 | REVISED DRAWINGS SUBMITTED. JG. | | | | RESIDENTIAL (R3) ADDITION/ALTERATION PLUMBING REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PLANS SUBMITTED NEED TO HAVE ARCHITECT'S ORIGINAL | | SEAL AND SIGNATURE. PERMIT APPLICATION AND PLANS | | SUBMITTED ARE HARD COPIES NOT DIGITAL SUBMITTAL. PLANS | | SUBMITTED SHOW A DIGITAL SIGNATURE. THIS IS NOT ALLOWED | | ON HARD COPIES SUBMITTAL. SEC. 481.221 F.S. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-06-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-06-23 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-21 |
Time |
15:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2017-11-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-06 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-06 |
Time |
16:06 |
Sent To |
|
|
Notes |
2017-11-06 16:07:42 | ASPHALT SHINGLES FL18355-R2. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
AW |
Date |
2017-12-12 |
Time |
|
Rev Time |
0.00 |
Received By |
ajones |
Date |
2017-12-06 |
Time |
16:01 |
Sent To |
|
|
Notes |
2017-11-28 16:09:47 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-11-09 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2017-11-08 |
Time |
|
Sent To |
|
|
Notes |
2017-11-06 11:43:49 | NEW PLANS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-10-05 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2017-10-05 |
Time |
|
Sent To |
|
|
Notes |
2017-10-04 16:56:29 | ROUTED TO ALANA WOOTEN | 2017-10-03 15:27:25 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2017-09-05 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2017-09-05 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
awooten |
Date |
2017-09-05 |
Time |
|
Sent To |
E |
|
Notes |
2017-09-05 09:49:35 | **************ZONING REVIEW | | FAILED*************************** | | | | PLESE ADDRESS THE COMMENTS FROM PLUMBING ABOUT THE | | PLANS BEING SIGNED AND SEALED. | | | | THANKS, | | ALANA WOOTEN | | ASSOCIATE PLANNER | | ZONING | | 561-822-1449 | | [email protected] | 2017-08-28 09:25:59 | REVISED DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-07-13 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2017-07-13 |
Time |
10:31 |
Sent To |
B |
|
Notes |
2017-07-12 16:45:36 | ROUTED TO ALANA WOOTEN |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-06-13 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2017-06-13 |
Time |
11:45 |
Sent To |
|
|
Notes |
2017-06-14 11:23:22 | *****************ZONING | | REVIEW**************************** | | | | ENCLOSING CARPORT--PLEASE SUBMIT SURVEY. | | | | PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS. | | | | THANKS, | | ALANA WOOTEN | | ASSOCIATE PLANNER | | [email protected] | | 561-822-1449 |
|
|