Plan Review Details - Permit 17060265
Plan Review Stops For Permit 17060265
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2017-12-19 Cont ID  
Sent By jgomez Date 2017-12-19 Time 16:45 Rev Time 0.00
Received By jgomez Date 2017-12-19 Time 12:55 Sent To  
Notes
2017-12-19 12:57:4512/19/17 MET WITH KEVIN. HE SAID TO PROCESS PERMIT WITH
 PROVISO. JG.
  
  
 BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE COMPLETE REVISED ENERGY CALCULATIONS REPORT.
 NOTE: COORDINATE WITH PLANS.
 2- REVISE DOORS INFORMATION ON PAGE 3 OF 4 TO MATCH
 PLANS & PRODUCT APPROVALS.
 3- COORDINATE COOLING AND HEATING INFORMATION TO MATCH
 EQUIPMENT SIZING CALCULATIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2017-12-15 Cont ID  
Sent By jgomez Date 2017-12-15 Time 16:58 Rev Time 0.00
Received By jgomez Date 2017-12-15 Time 16:16 Sent To  
Notes
2017-12-15 16:17:25 
 RESIDENTIAL (R3) ADDITION/ALTERATION 7TH BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE: ON PREVIOUS REVIEWS THE PROVISO OPTION WAS
 OFFERED. UNFORTUNATELY, RE-SUBMITTALS ARE RAISING MORE
 QUESTIONS THAN ANSWERS, THEREFORE DELAYING THE PERMIT
 PROCESS.
  
 ENERGY CALCULATIONS SUBMITTED:
 1- ENERGY CALCULATIONS NEED TO BE CERTIFIED AT THE
 BOTTOM OF THE FORM BY THE OWNER OR LEGALLY DESIGNATED
 AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 2- HEATING AND COOLING INFORMATION SHOWN ON THE REVISED
 ENERGY CALCULATIONS DOESN'T MATCH INFORMATION SHOWN ON
 THE EQUIPMENT SIZING CALCULATIONS SUBMITTED.
 RESPONSE: REPEAT COMMENT. REVISE AS REQUIRED TO MATCH.
  
 3- ON PREVIOUS REVIEW IT WAS REQUESTED TO SUBMIT THE
 COMPLETE ENERGY CALCULATIONS REPORT BECAUSE THEY WERE
 REVISED AND ONLY SOME PAGES WERE SUBMITTED. REPORT
 SUBMITTED NOW IS MISMATCHING PAGES FROM OLD REPORTS
 WITH PAGES OF THE LATEST REVISED REPORT. SOME PAGES ARE
 DATED 12/5/17 AND SOME PAGES ARE DATED 10/25/17. WHEN
 THERE ARE CHANGES A COMPLETE REPORT RUN ON THE SAME
 DATED NEED TO BE GENERATED. MISMATCHING PAGES IS NOT
 ALLOWED BECAUSE ANY CHANGE AFFECTS THE OVERALL REPORT.
 NOTE: INFORMATION SHOWN ON PAGE 3 OF 4 DATED 10/25/17
 IS INCORRECT. FOR EXAMPLE THE WINDOWS INFORMATION
 DOESN'T MATCH PLANS. PROVIDE COMPLETE ENERGY
 CALCULATIONS REPORT THAT MATCHES PLANS TO AVOID MORE
 DELAYS OR CONFLICTS.
  
 4- DOORS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T MATCH
 PLANS. CLARIFY WHICH INSULATED DOORS ARE LOCATED EAST
 AND WEST. REVISE AS REQUIRED TO MATCH PLANS AND PRODUCT
 APPROVALS SUBMITTED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION. NOTE: ONLY THE DOORS THAT SEPARATE A/C
 SPACE FROM NON A/C SPACE ARE TO BE CONSIDERED.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2017-11-30 Cont ID  
Sent By jgomez Date 2017-11-30 Time 11:32 Rev Time 0.00
Received By jgomez Date 2017-11-30 Time 11:32 Sent To  
Notes
2017-11-28 16:03:16RESIDENTIAL (R3) ADDITION/ALTERATION SIXTH BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO: PROVISO
 MEANS THAT CONTRACTOR MAY SUBMIT REQUIRED REVISED
 INFORMATION AFTER THE PERMIT IS ISSUED, BUT BEFORE ANY
 INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO
 ADVICE IF THE PROVISO OPTION IS PREFERRED AT THIS TIME.
 REVISION FEES APPLY IF INFORMATION IS SUBMITTED AFTER
 THE PERMIT IS ISSUED.
  
 NEW COMMENT:
 1- EQUIPMENT SPECIFIED ON THE NEW ENERGY CALCULATIONS
 SUBMITTED DOESN'T MATCH EQUIPMENT SHOWN ON THE A/C PLAN
 SUBMITTED. EQUIPMENT SIZE AND MANUFACTURER DON'T MATCH.
 REVISE AS REQUIRED TO MATCH. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
 NOTE: COORDINATE WITH EQUIPMENT CALCULATIONS REQUESTED
 ON THE MECHANICAL REVIEW. SEE MECHANICAL REVIEW
 COMMENTS.
  
 2- NEW ENERGY CALCULATIONS FORM 405-2014 SUBMITTED:
 ORIGINAL COMMENT:
 A) PERSON PREPARING THE ENERGY CALCULATIONS IS TAKING
 THE "WHOLE HOUSE FAN OPTION". IN ORDER TO TAKE THIS
 CREDIT THE REQUIREMENTS OF SEC. R405.7.5 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014) MUST BE MET.
 ARCHITECTURAL PLANS DON'T SHOW ANY INFORMATION FOR
 WHOLE HOUSE FAN. PERSON PREPARING THE ENERGY
 CALCULATIONS TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS SHOWING HOW THESE REQUIREMENTS ARE MET.
 RESPONSE:
 IT LOOKS LIKE THE ENERGY CALCULATIONS WERE REVISED BUT
 THE ENERGY CALCULATIONS WERE NOT RESUBMITTED IN ITS
 ENTIRETY. ONLY A COUPLE OF PAGES WERE RESUBMITTED.
 SUBMIT 2 COPIES OF COMPLETE REVISED ENERGY
 CALCULATIONS.
  
 ORIGINAL COMMENT:
 B) DOORS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T MATCH
 PLANS. CLARIFY WHICH INSULATED DOORS ARE LOCATED EAST
 AND WEST. REVISE AS REQUIRED TO MATCH PLANS AND PRODUCT
 APPROVALS SUBMITTED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
 RESPONSE:
 CALCULATIONS WERE REVISED BUT THEY DON'T MATCH PLANS.
 WHICH 36"X80" INSULATED DOOR IS LOCATED IN THE SOUTH
 WALL?. AND, WHICH 26"X80" INSULATED DOOR IS LOCATED IN
 THE NORTH WALL?. NOTE: ONLY THE DOORS THAT SEPARATE A/C
 AREA FROM NON A/C AREA ARE THE ONES TO BE CONSIDERED.
  
 2- TRUSS PACKAGE SUBMITTED;
 A) ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 TRUSS PACKAGE BEFORE SUBMITTAL TO THIS OFFICE. SEC.
 107.3.4.2 CITY AMENDMENTS.
 RESPONSE:
 SHOP DRAWINGS REVIEW STAMP IS MISSING THE ARCHITECT'S
 INFORMATION. IT DOESN'T IDENTIFY WHO REVIEW THE TRUSS
 PACKAGE. PROVIDE SHOP DRAWINGS REVIEW STAMP THAT
 INCLUDES THE ARCHITECT'S INFORMATION.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2017-11-06 Cont ID  
Sent By jgomez Date 2017-11-06 Time 15:38 Rev Time 0.00
Received By jgomez Date 2017-11-06 Time 10:50 Sent To  
Notes
2017-11-06 11:24:30RESIDENTIAL (R3) ADDITION/ALTERATION FIFTH BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO: PROVISO
 MEANS THAT CONTRACTOR MAY SUBMIT REQUIRED REVISED
 INFORMATION AFTER THE PERMIT IS ISSUED, BUT BEFORE ANY
 INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO
 ADVICE IF THE PROVISO OPTION IS PREFERRED AT THIS TIME.
 REVISION FEES APPLY.
  
  
 1- NEW ENERGY CALCULATIONS FORM 405-2014 SUBMITTED:
 A) PERSON PREPARING THE ENERGY CALCULATIONS IS TAKING
 THE "WHOLE HOUSE FAN OPTION". IN ORDER TO TAKE THIS
 CREDIT THE REQUIREMENTS OF SEC. R405.7.5 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014) MUST BE MET.
 ARCHITECTURAL PLANS DON'T SHOW ANY INFORMATION FOR
 WHOLE HOUSE FAN. PERSON PREPARING THE ENERGY
 CALCULATIONS TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS SHOWING HOW THESE REQUIREMENTS ARE MET.
 NOTE: THIS INFORMATION IS ONLY REQUIRED WHEN THE ENERGY
 CALCULATIONS ARE TAKING ANY CREDITS ON ITEM #15.
  
 B) DOORS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T MATCH
 PLANS. CLARIFY WHICH INSULATED DOORS ARE LOCATED EAST
 AND WEST. REVISE AS REQUIRED TO MATCH PLANS AND PRODUCT
 APPROVALS SUBMITTED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 C) WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T
 MATCH PLANS. REVISE AS REQUIRED. REVISE WINDOWS
 ORIENTATION AND SQUARE FOOTAGE TO MATCH PLANS AND
 PRODUCT APPROVALS SUBMITTED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
 NOTE: SEE SURVEY FOR CORRECT BUILDING ORIENTATION TO
 AVOID MORE CONFLICTS/DELAYS.
  
 2- TYPICAL WALL SECTION @ FAMILY ROOM: PLANS WERE
 REVISED TO BUILD A NEW ROOF OVER THE PROPOSED FAMILY
 AREA ADDITION. SPECIFY ROOF VENTILATION AS REQUIRED BY
 SEC. R806 FBC-RESIDENTIAL, 5TH EDITION (2014). REVISED
 WALL SECTION IS MISSING THIS INFORMATION. SPECIFY VENT
 SIZE AND SPACING.
  
 3- TRUSS PACKAGE SUBMITTED;
 A) MISSING THE TRUSS LAYOUT. NOTE: TRUSS LAYOUT AND
 ARCHITECT'S ROOF FRAMING PLAN NEED TO MATCH. SEC.
 R301.1 FBC-RESIDENTIAL. PROVIDE TRUSS LAYOUT.
  
 B) ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 TRUSS PACKAGE BEFORE SUBMITTAL TO THIS OFFICE. SEC.
 107.3.4.2 CITY AMENDMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2017-10-03 Cont ID  
Sent By jgomez Date 2017-10-03 Time 15:11 Rev Time 0.00
Received By jgomez Date 2017-10-02 Time 10:37 Sent To  
Notes
2017-10-02 11:31:59RESIDENTIAL (R3) ADDITION/ALTERATION FOURTH BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO: PROVISO
 MEANS THAT CONTRACTOR MAY SUBMIT REQUIRED REVISED
 INFORMATION AFTER THE PERMIT IS ISSUED, BUT BEFORE ANY
 INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO
 ADVICE IF THE PROVISO OPTION IS PREFERRED AT THIS TIME.
 REVISION FEES APPLY. SIGN ENERGY CALCULATIONS.
  
  
 1- DIFFERENT ENERGY CALCULATIONS PRESCRIPTIVE FORM
 R402-2014 SUBMITTED:
 NOTE: PRESCRIPTIVE METHOD IS MORE STRICT THAN THE
 PREVIOUS FORM R405-2014 SUBMITTED. NEED TO COMPLY WITH
 ALL THE REQUIREMENTS OF TABLE R402A. THE FOLLOWING
 CONDITIONS NEED TO BE MET:
 A) THE PRESCRIPTIVE FORM R402-2014 CAN NOT BE USED IF
 THE AIR HANDLER UNIT IS LOCATED IN THE ATTIC. SEE AIR
 DISTRIBUTION INFORMATION ON TABLE R402A OF FORM
 SUBMITTED. ACCORDING TO PLANS SUBMITTED, IT LOOKS LIKE
 THE AIR HANDLER IS LOCATED IN THE ATTIC OF THE MAIN
 HOUSE. CLEARLY IDENTIFY LOCATION OF AIR HANDLER UNIT.
  
 B) THE CONDITIONED FLOOR AREA SHOWN ON ITEM #5 NEEDS TO
 BE REVISED. THE PROPOSED ADDITION IS 19'-9" X 12'-5".
 THEREFORE THE CORRECT AREA IS =/- 245 S.F. NOT 208 S.F.
 NOTE: ARCHITECTURAL PLANS NEED TO BE REVISED ALSO.
  
 C) THE WINDOWS U-FACTOR AND SHGC FACTOR SHOWN ON ITEM
 #6 DON'T COMPLY WITH THE MIN. REQUIRED FACTORS SHOWN ON
 TABLE R402A. SEE GENERAL INSTRUCTION #1 ON FRONT PAGE
 OF FORM SUBMITTED AND REVISE AS REQUIRED. AND, PROVIDE
 WINDOW AND DOORS MANUFACTURER'S SPECS SHOWING THAT THE
 PROPOSED WINDOWS MEET THE REQUIRED FACTORS.
  
 D) THE CONCRETE BLOCK WALL INFORMATION SHOWN ON ITEM
 #9(A)(2). CONCRETE BLOCK WALLS NEED TO HAVE INSULATION
 ON THE INTERIOR AND EXTERIOR SIDE OF THE WALL AS
 REQUIRED BY TABLE R402A . SEE NOTE #4 OF TABLE R402A.
 PLANS DON'T SHOW ANY INSULATION ON THE INTERIOR AND
 EXTERIOR SIDE OF THE WALL. PERSON PREPARING THE ENERGY
 CALCULATIONS TO PROVIDE COMPLETE DOCUMENTATION SHOWING
 COMPLIANCE WITH THIS REQUIREMENT. SEC. R103.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). REVISE AS
 REQUIRED.
  
 E) THE CEILING INFORMATION ON ITEM 10 DOESN'T COMPLY
 WITH TABLE R402A. THIS IS A SINGLE ASSEMBLY CEILING,
 THERE IS NOT ATTIC AND THE MINIMUM CEILING INSULATION
 REQUIRED BY TABLE R402A IS R-30. ALSO, ACCORDING TO
 ARCHITECTURAL PLANS THE CEILING JOISTS ARE 2X6. IT
 DOESN'T SEEM TO BE ENOUGH ROOM FOR THE R-30 INSULATION.
 PROVIDE COMPLETE DETAILS L AND SPECIFICATIONS SHOWING
 HOW INSTALLING R-30 INSULATION ON A 2X6 ROOF JOIST?.
 SEC. R1074.2.1 CITY AMENDMENTS. ALSO, COORDINATE
 CEILING AREA WITH ITEM #1(B) ABOVE.
  
 F) NEED TO COMPLETE THE MANDATORY REQUIREMENTS OF TABLE
 R402B AS REQUIRED BY NOTE #3 OF THE GENERAL
 INSTRUCTIONS OF FORM R402-2014 SUBMITTED.
  
 G) OWNER OR LEGALLY DESIGNATED AGENT NEED TO CERTIFY
 AND DATE AT THE BOTTOM OF THE ENERGY CALCULATIONS
 SUBMITTED AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 RESPONSE: REPEAT COMMENT. NEW FORM SUBMITTED WAS NOT
 CERTIFIED AT THE BOTTOM OF THE FORM BY THE OWNER.
 PERMIT CAN NOT BE ISSUED WITHOUT THE OWNER'S
 CERTIFICATION.
  
 NOTE:
 LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND
 SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS IS
 REQUIRED WHEN CALCULATIONS ARE NO USING THE DEFAULT
 FACTORS.
  
  
 2- THE "NEW PORCH ENCLOSURE" CONDITIONED FLOOR AREA
 SHOWN ON THE AREA CALCULATIONS NEEDS TO BE REVISED. THE
 PROPOSED "PORCH ENCLOSURE" ADDITION IS 19'-9" X 12'-5".
 THEREFORE THE CORRECT AREA IS =/- 245 S.F. NOT 208 S.F.
 NOTE: ARCHITECTURAL PLANS NEED TO BE REVISED. SEC.
 107.2.1 CITY AMENDMENTS.
  
 3- TYPICAL WALL SECTION @ FAMILY ROOM:
 A) SPECIFY CEILING INSULATION. SEC. R103.2 FBC-ENERGY
 CONSERVATION. NOTE: KEEP IN MIND SIZE OF EXISTING ROOF
 JOISTS (2X6). SPECIFY INSULATION TYPE AND R-VALUE.
 ALSO, WALL SECTION SPECIFIES "EXISTING VENTED SOFFIT".
 KEEP IN MIND THE CLEARANCE REQUIRED BETWEEN THE
 INSULATION AND UNDERSIDE OF ROOF SHEATHING FOR CROSS
 VENTILATION AS REQUIRED BY SEC. R806.3 FBC-RESIDENTIAL,
 5TH EDITION (2014).
 (REPEAT COMMENT).
  
 B) SPECIFY R-VALUE FOR CONCRETE BLOCK WALL INSULATION.
 SEC. R103.2 FBC-ENERGY CONSERVATION.
 (REPEAT COMMENT).
  
 C) PROVIDE SPECIFICATIONS FOR NEW CEILING FINISH THAT
 IS COVERING THE INSULATION. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 NOTE:
 ARCHITECT MAY BE CHARGED FOUR TIMES THE PLAN REVIEW
 FEES FOR MULTIPLE REJECTIONS AS REQUIRED BY FLORIDA
 STATUTE 553.80(2)(B)
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2017-08-28 Cont ID  
Sent By jgomez Date 2017-08-28 Time 18:43 Rev Time 0.00
Received By jgomez Date 2017-08-28 Time 09:19 Sent To  
Notes
2017-08-28 09:24:41RESIDENTIAL (R3) ADDITION/ALTERATION THIRD BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- ENERGY CALCULATIONS SUBMITTED (NOTE: ENERGY
 CALCULATIONS AND PLANS NEED TO BE COORDINATED TO AVOID
 CONFLICT/DELAYS):
 A) OWNER OR LEGALLY DESIGNATED AGENT NEED TO CERTIFY
 AND DATE AT THE BOTTOM OF THE ENERGY CALCULATIONS
 SUBMITTED AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 B) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD SUBMITTED AS REQUIRED BY SEC.
 R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 C) PLANS SUBMITTED DON'T SHOW ANY INFORMATION FOR THE
 R-30 CEILING INSULATION (SPECIALLY ON THE FLAT ROOF OF
 THE FAMILY AREA ADDITION) AND WALLS. PERSON PREPARING
 THE ENERGY CALCULATIONS TO CLARIFY WHERE IS THIS
 INFORMATION TAKEN FROM. NOTE: R-30 INSULATION MAY NOT
 FIT IN THE FLAT ROOF OF THE NEW ADDITION. ALSO, PLANS
 SUBMITTED DON'T SHOW ANY OVERHANG ON THE FLAT ROOF.
 COORDINATE WITH ARCHITECT OF RECORD TO AVOID
 CONFLICT/DELAYS AND REVISE AS REQUIRED. SEC. R103.2.1
 FBC-ENERGY CONSERVATION.
  
 D) PLANS SUBMITTED DON'T SHOW ANY INFORMATION FOR THE
 CEILING VENTILATION ON THE FAMILY ADDITION AND GARAGE
 ENCLOSURE. PERSON PREPARING THE ENERGY CALCULATIONS TO
 CLARIFY WHERE IS THIS INFORMATION TAKEN FROM. ALSO,
 PLANS SUBMITTED DON'T SHOW ANY OVERHANG ON THE FLAT
 ROOF. COORDINATE WITH ARCHITECT OF RECORD TO AVOID
 CONFLICT/DELAYS AND REVISE AS REQUIRED. SEC. R103.2.1
 FBC-ENERGY CONSERVATION.
  
 E) REVISE THE ROOF TYPE ON PAGE 2 OF 4. THE ROOF TYPE
 IS GABLE NOT HIP. REVISE THE GABLE AREA AS WELL. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 F) DOORS INFORMATION ON PAGE 3 OF 4 SPECIFY 3 INSULATED
 DOORS. COORDINATE WITH PLANS AND PRODUCT APPROVALS AND
 REVISE AS REQUIRED. NOTE: OVERHEAD GARAGE DOORS ARE NO
 TO BE CONSIDERED. DOORS TO BE BE CONSIDERED ARE THOSE
 THAT SEPARATE A/C SPACE FROM NON-A/C SPACE. REVISE AS
 REQUIRED.
  
 NOTE:
 LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND
 SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS IS
 REQUIRED WHEN CALCULATIONS ARE NO USING THE DEFAULT
 FACTORS.
  
 2- PLANS SUBMITTED NEED TO HAVE ARCHITECT'S ORIGINAL
 SEAL AND SIGNATURE. PERMIT APPLICATION AND PLANS
 SUBMITTED ARE HARD COPIES NOT DIGITAL SUBMITTAL. PLANS
 SUBMITTED SHOW A DIGITAL SIGNATURE. THIS IS NOT ALLOWED
 ON HARD COPIES SUBMITTAL. SEC. 481.221 F.S.
  
 3- PROVIDE COMPLETE WALL SECTION THRU THE NEW FAMILY
 ROOM ADDITION AND THRU THE NEW GARAGE ENCLOSURE.
 SPECIFY ALL THE STRUCTURAL CONNECTIONS SHOWING
 COMPLIANCE WITH THE LOAD PATH AS REQUIRED BY SEC.
 R801.2, R601.2 AND R401.2 FBC-RESIDENTIAL.
 RESPONSE. CLEARLY SPECIFY TYPE AND SIZE OF SIMPSON MTS
 STRAP. SPECIFIED STRAP IS A WOOD TO WOOD CONNECTOR.
 PROPOSED CONSTRUCTION LOOKS LIKE WOOD TO CONCRETE
 BLOCK. SPECIFY SPACING OF STRAPS FROM WOOD BEAM TO
 CONCRETE BLOCK BEAM. REVISE/CLARIFY DETAIL AS REQUIRED.
  
 4- PROVIDE COMPLETE ROOF FRAMING PLAN FOR THE FAMILY
 ROOM ADDITION. SEC. R301.1 FBC-RESIDENTIAL. SPECIFY ALL
 FRAMING MEMBERS SIZES AND CONNECTORS.
 RESPONSE. REPEAT COMMENT. THERE IS NO INFORMATION ABOUT
 THE ROOF FRAMING SYSTEM AND CONNECTORS. SPECIFY FRAMING
 MEMBERS SIZING, SPACING AND CONNECTORS TO VERIFY
 COMPLIANCE WITH THE CURRENT WIND LOADS. NOTE: THIS AREA
 WAS AN ENCLOSED PORCH. NOW IS PROPOSED TO BE LIVABLE
 AREA. THAT'S WHY THE STRUCTURE NEEDS TO COMPLY WITH
 CURRENT WIND LOADS.
  
 5- ENERGY CALCULATIONS SUBMITTED CALL FOR R-30 CEILING
 INSULATION. PLANS NEED TO PROVIDE SPECIFICATIONS FOR
 THE CEILING AND WALLS INSULATION AS REQUIRED BY SEC.
 R103.1.1.2 FBC-ENERGY CONSERVATION. NOTE: KEEP IN MIND
 THAT R-30 BUTT INSULATION IS ABOUT 9-1/2" THICK. SIZE
 OF ROOF FRAMING MEMBERS MAY NOT ALLOW R-30 INSULATION
 AND CROSS VENTILATION (IF VENTILATION IS SPECIFIED BY
 THE ARCHITECT). COORDINATE WITH ITEM #4, ITEM #1(C) AND
 #1(D) ABOVE.
  
 6- SPECIFY ROOF VENTILATION FOR THE FAMILY ROOM
 ADDITION AND GARAGE ENCLOSURE. SEC. R806.1
 FBC-RESIDENTIAL.
 RESPONSE. REPEAT COMMENT. ENERGY CALCULATIONS AND PLANS
 NEED TO BE COORDINATED TO AVOID CONFLICTS/DELAYS.
 COORDINATE WITH ITEM #1(C) AND #1(D) ABOVE.
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS. PROVIDE THE FLORIDA PRODUCT APPROVAL COVER PAGE
 THAT CORRESPONDS TO REPORT SUBMITTED. OR ARCHITECT TO
 LIST THE CURRENT FLORIDA PRODUCT APPROVAL NUMBER NEXT
 TO EACH SPECIFIED CONNECTOR.
  
 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL THE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
 RESPONSE.
 A) ARCHITECT'S LETTER SUBMITTED IS TOO GENERAL. IF
 USING A LETTER AS A RESPONSE FOR THE REVIEW OF EACH
 PRODUCT APPROVAL, THEN CLEARLY IDENTIFY EACH PRODUCT
 APPROVAL BY MANUFACTURER'S NAME AND SPECIFIC NOA OR
 FLORIDA PRODUCT APPROVAL NUMBER.
  
 B) LETTER SUBMITTED NEEDS ARCHITECT'S ORIGINAL SEAL AND
 SIGNATURE. PERMIT APPLICATION AND PLANS SUBMITTED ARE
 HARD COPIES NOT DIGITAL SUBMITTAL. LETTER SUBMITTED
 SHOW A DIGITAL SIGNATURE. THIS IS NOT ALLOWED ON HARD
 COPIES SUBMITTAL. SEC. 481.221 F.S.
  
 9- NEW GARAGE DOOR PRODUCT APPROVAL SUBMITTED REQUIRES
 4.000 PSI MINIMUM CONCRETE JAMB. SEE NOA 14-0822.06
 SUBMITTED. REVISE GARAGE DOOR JAMB DETAILS AND
 SPECIFICATIONS ON THE FLOOR PLAN AND DETAILS AS
 REQUIRED BY THE NOA SUBMITTED. SEC. R301.1
 FBC-RESIDENTIAL.
  
 *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-07-17 Cont ID  
Sent By jgomez Date 2017-07-17 Time 11:53 Rev Time 0.00
Received By jgomez Date 2017-07-17 Time 11:27 Sent To  
Notes
2017-07-17 11:29:43RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 3- PLANS SUBMITTED ARE MISSING SHEET 2 OF 2. SEC.
 107.2.1 CITY AMENDMENTS. PROVIDE COMPLETE SET OF PLANS.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 4- SPECIFY CARBON MONOXIDE ALARMS BY ALL THE BEDROOMS
 AS REQUIRED BY SEC. R315.1 FBC-RESIDENTIAL, 5TH EDITION
 (2014).
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 5- OPENING BETWEEN EXISTING BATHROOM AND PROPOSED
 GARAGE NEEDS TO COMPLY WITH THE OPENING PROTECTION AS
 REQUIRED BY SEC. R302.5.1 FBC-RESIDENTIAL. REVISE PLANS
 SHOWING COMPLIANCE.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 6- PROVIDE SPECIFICATIONS FOR THE GARAGE DOOR FIRE
 SPECIFICATIONS AND SELF CLOSING DEVICE AS REQUIRED BY
 SEC. R302.5.1 FBC-RESIDENTIAL.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 7- EXISTING BATHROOM ADJACENT TO THE PROPOSED GARAGE
 NEEDS TO COMPLY WITH THE VENTILATION REQUIREMENTS OF
 SEC. R303.3 FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS FOR
 THE VENTILATION. NOTE: COORDINATE WITH ITEM # 5 ABOVE.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 8- PROVIDE COMPLETE WALL SECTION THRU THE NEW FAMILY
 ROOM ADDITION AND THRU THE NEW GARAGE ENCLOSURE.
 SPECIFY ALL THE STRUCTURAL CONNECTIONS SHOWING
 COMPLIANCE WITH THE LOAD PATH AS REQUIRED BY SEC.
 R801.2, R601.2 AND R401.2 FBC-RESIDENTIAL.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 9- PROVIDE FOUNDATION PLAN FOR NEW FAMILY ROOM ADDITION
 AND PROPOSED GARAGE. SEC. R301.1 FBC-RESIDENTIAL.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 10- PROVIDE COMPLETE ROOF FRAMING PLAN FOR THE FAMILY
 ROOM ADDITION. SEC. R301.1 FBC-RESIDENTIAL. SPECIFY ALL
 FRAMING MEMBERS SIZES AND CONNECTORS.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 11- SPECIFY ROOF VENTILATION FOR THE FAMILY ROOM
 ADDITION. SEC. R806.1 FBC-RESIDENTIAL.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 12- PROVIDE OVERHEAD GARAGE DOOR STRUCTURAL BUCK
 DETAIL. SEC. R301.1 FBC-RESIDENTIAL.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 13- PROVIDE STRUCTURAL BUCK DETAIL FOR NEW FRENCH DOORS
 AND WINDOWS. SEC. R612..7.2.1 FBC-RESIDENTIAL.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 14- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) WINDOW MULLIONS AS SPECIFIED ON PLANS. NOTE:
 ARCHITECT OF RECORD TO SPECIFY MULLION SIZE TO BE USED
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC.
 R301.1 FBC-RESIDENTIAL.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 B) PRECAST LINTELS AS SPECIFIED ON PLANS.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 C) ALL SIMPSON (OR ANY OTHER STRUCTURAL CONNECTOR)
 STRUCTURAL CONNECTORS SPECIFIED ON PLANS. PROVIDE ONLY
 THE FLORIDA PRODUCT APPROVAL COVER PAGE AND PAGE
 SHOWING THE SPECIFIED CONNECTOR. OR ARCHITECT TO LIST
 THE CURRENT FLORIDA PRODUCT APPROVAL NUMBER NEXT TO
 EACH SPECIFIED CONNECTOR.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 D) NEW OVERHEAD GARAGE DOOR THAT MEETS THE SIZE
 SPECIFIED ON PLANS. NOA 15-0225.06 SUBMITTED IS FOR
 GARAGE DOORS UP TO 9'-0" WIDE. SIZE OF DOOR SPECIFIED
 ON PLANS IS WIDER.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 15- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN
 WRITING (NOT SIGNING AND SEALING) ALL THE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 16- PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR THE
 NEW OPENING AND FRAMING FOR RELOCATED DOOR BETWEEN THE
 GARAGE AND KITCHEN AREA. SEC. R301.1 FBC-RESIDENTIAL.
 AND PROVIDE DETAIL./SPECS FOR CLOSING THE EXISTING DOOR
 OPENING.
 RESPONSE. REPEAT COMMENT. NOT ADDRESSED.
  
 *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-07-10 Cont ID  
Sent By jgomez Date 2017-07-10 Time 09:37 Rev Time 0.00
Received By jgomez Date 2017-07-10 Time 09:16 Sent To  
Notes
2017-07-10 09:18:29RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE.
  
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 3- PLANS SUBMITTED ARE MISSING SHEET 2 OF 2. SEC.
 107.2.1 CITY AMENDMENTS. PROVIDE COMPLETE SET OF PLANS.
  
 4- SPECIFY CARBON MONOXIDE ALARMS BY ALL THE BEDROOMS
 AS REQUIRED BY SEC. R315.1 FBC-RESIDENTIAL, 5TH EDITION
 (2014).
  
 5- OPENING BETWEEN EXISTING BATHROOM AND PROPOSED
 GARAGE NEEDS TO COMPLY WITH THE OPENING PROTECTION AS
 REQUIRED BY SEC. R302.5.1 FBC-RESIDENTIAL. REVISE PLANS
 SHOWING COMPLIANCE.
  
 6- PROVIDE SPECIFICATIONS FOR THE GARAGE DOOR FIRE
 SPECIFICATIONS AND SELF CLOSING DEVICE AS REQUIRED BY
 SEC. R302.5.1 FBC-RESIDENTIAL.
  
 7- EXISTING BATHROOM ADJACENT TO THE PROPOSED GARAGE
 NEEDS TO COMPLY WITH THE LIGHT AND VENTILATION
 REQUIREMENTS OF SEC. R303.3 FBC-RESIDENTIAL. PROVIDE
 SPECIFICATIONS FOR THE LIGHT AND VENTILATION. NOTE:
 COORDINATE WITH ITEM # 5 ABOVE.
  
 8- PROVIDE COMPLETE WALL SECTION THRU THE NEW FAMILY
 ROOM ADDITION AND THRU THE NEW GARAGE ENCLOSURE.
 SPECIFY ALL THE STRUCTURAL CONNECTIONS SHOWING
 COMPLIANCE WITH THE LOAD PATH AS REQUIRED BY SEC.
 R801.2, R601.2 AND R401.2 FBC-RESIDENTIAL.
  
 9- PROVIDE FOUNDATION PLAN FOR NEW FAMILY ROOM ADDITION
 AND PROPOSED GARAGE. SEC. R301.1 FBC-RESIDENTIAL.
  
 10- PROVIDE COMPLETE ROOF FRAMING PLAN FOR THE FAMILY
 ROOM ADDITION. SEC. R301.1 FBC-RESIDENTIAL. SPECIFY ALL
 FRAMING MEMBERS SIZES AND CONNECTORS.
  
 11- SPECIFY ROOF VENTILATION FOR THE FAMILY ROOM
 ADDITION. SEC. R806.1 FBC-RESIDENTIAL.
  
 12- PROVIDE OVERHEAD GARAGE DOOR STRUCTURAL BUCK
 DETAIL. SEC. R301.1 FBC-RESIDENTIAL.
  
 13- PROVIDE STRUCTURAL BUCK DETAIL FOR NEW FRENCH DOORS
 AND WINDOWS. SEC. R612..7.2.1 FBC-RESIDENTIAL.
  
 14- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) WINDOW MULLIONS AS SPECIFIED ON PLANS. NOTE:
 ARCHITECT OF RECORD TO SPECIFY MULLION SIZE TO BE USED
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC.
 R301.1 FBC-RESIDENTIAL.
  
 B) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 C) ALL SIMPSON (OR ANY OTHER STRUCTURAL CONNECTOR)
 STRUCTURAL CONNECTORS SPECIFIED ON PLANS. PROVIDE ONLY
 THE FLORIDA PRODUCT APPROVAL COVER PAGE AND PAGE
 SHOWING THE SPECIFIED CONNECTOR. OR ARCHITECT TO LIST
 THE CURRENT FLORIDA PRODUCT APPROVAL NUMBER NEXT TO
 EACH SPECIFIED CONNECTOR.
  
 D) NEW OVERHEAD GARAGE DOOR THAT MEETS THE SIZE
 SPECIFIED ON PLANS. NOA 15-0225.06 SUBMITTED IS FOR
 GARAGE DOORS UP TO 9'-0" WIDE. SIZE OF DOOR SPECIFIED
 ON PLANS IS WIDER.
  
 15- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN
 WRITING (NOT SIGNING AND SEALING) ALL THE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 16- PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR THE
 NEW OPENING AND FRAMING FOR RELOCATED DOOR BETWEEN THE
 GARAGE AND KITCHEN AREA. SEC. R301.1 FBC-RESIDENTIAL.
 AND PROVIDE DETAIL./SPECS FOR CLOSING THE EXISTING DOOR
 OPENING.
  
 *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2017-12-05 Cont ID  
Sent By jleahy Date 2017-12-05 Time 12:26 Rev Time 0.00
Received By jleahy Date 2017-12-05 Time 12:26 Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2017-11-13 Cont ID  
Sent By jleahy Date 2017-11-13 Time 08:35 Rev Time 0.00
Received By jleahy Date 2017-11-13 Time 08:35 Sent To  
Notes
2017-11-13 08:49:25FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 GARAGE DOES NOT SHOW ANY OUTLETS. CODE STATES: "AT
 LEAST ONE RECEPTACLE OUTLET, IN ADDITION TO THOSE FOR
 SPECIFIC EQUIPMENT, SHALL BE INSTALLED IN EACH
 BASEMENT, IN EACH ATTACHED GARAGE, AND IN EACH DETACHED
 GARAGE OR ACCESSORY BUILDING WITH ELECTRIC POWER".
 PROVIDE OUTLET. NEC 210.52(G); FBC RE3901.9
  
 PROVIDE GFCI PROTECTION FOR ALL OUTLETS IN GARAGE. NEC
 210.8; FBC RE3902.2
  
 PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER
 CODE. FBC R314.3, 315.1; FBC 107.2.1
  
 PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF EACH
 ROOM USED FOR SLEEPING PURPOSES. FBC R315.1
  
  
 SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE
 INSTALLED
 SO THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR
 LINE OF ANY WALL SPACE IS MORE THAN 6 FEET FROM A
 RECEPTACLE OUTLET. PROVIDE CORRECTION. NEC 210.52; FBC
 RE3901.2.1
  
 THE WALL SPACING REQUIREMENTS FOR KITCHEN COUNTER SPACE
 STATE THAT RECEPTACLE OUTLETS SHALL BE INSTALLED
 SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24
 INCHES MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET
 IN THAT SPACE. THE PLAN PROVIDED DOES NOT MEET THIS
 CODE IN SOME AREAS. PROVIDE CORRECTION. NEC
 210.52(C)(1);
 FBC RE3901.4
  
 E3903.2 HABITABLE ROOMS. AT LEAST ONE WALL
 SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED IN
 EVERY HABITABLE
 ROOM AND BATHROOM. [210.70(A)(1)] GARAGE AND NEW PORCH
  
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2017-10-04 Cont ID  
Sent By jleahy Date 2017-10-04 Time 16:09 Rev Time 0.00
Received By jleahy Date 2017-10-04 Time 16:09 Sent To Z
Notes
2017-10-04 16:10:35SEE REVIEW #2 FOR NOTES JLEAHY
2017-10-03 15:24:15NEW DRAWINGS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-09-06 Cont ID  
Sent By jleahy Date 2017-09-06 Time 11:00 Rev Time 0.00
Received By jleahy Date 2017-09-06 Time 11:00 Sent To  
Notes
2017-09-06 11:04:09FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NEED RISER DIAGRAM, LOAD CALCULATION.
  
 OUTLET AND LIGHTING OUTLETS NOT PER ARTICLE 210
2017-08-28 09:25:14REVISED DRAWINGS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-06-23 Cont ID  
Sent By jleahy Date 2017-06-23 Time 14:36 Rev Time 0.00
Received By jleahy Date 2017-06-23 Time 14:13 Sent To  
Notes
2017-06-23 14:37:16NEED RISER DIAGRAM
  
 LOAD CALCULATION
  
 PANEL SCHEDULE BEFORE FINAL ELECTRICAL INSPECTION

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2017-12-19 Cont ID  
Sent By jgomez Date 2017-12-19 Time 17:20 Rev Time 0.00
Received By jgomez Date 2017-12-19 Time 12:54 Sent To  
Notes
2017-12-19 12:55:18MET WITH KEVIN. HE SAID TO PROCESS PERMIT WITH PROVISO.
 JG.

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2017-12-15 Cont ID  
Sent By jgomez Date 2017-12-15 Time 18:12 Rev Time 0.00
Received By jgomez Date 2017-12-12 Time 15:44 Sent To I
Notes
2017-12-13 15:44:57RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date   Cont ID  
Sent By   Date 2017-12-12 Time   Rev Time 0.00
Received By lmarchan Date 2017-11-17 Time 14:10 Sent To  
Notes
2017-11-20 14:10:28R28

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2017-11-13 Cont ID  
Sent By jleahy Date 2017-11-13 Time 09:16 Rev Time 0.00
Received By jleahy Date 2017-10-26 Time 13:30 Sent To  
Notes
2017-10-27 13:30:34R24

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-10-05 Cont ID  
Sent By cpuell Date 2017-10-05 Time 16:09 Rev Time 0.00
Received By cpuell Date 2017-09-19 Time 18:55 Sent To  
Notes
2017-10-02 11:23:47R12
2017-09-19 18:55:27JGOMEZ'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-09-06 Cont ID  
Sent By jleahy Date 2017-09-06 Time 11:04 Rev Time 0.00
Received By jleahy Date 2017-08-23 Time 14:00 Sent To  
Notes
2017-08-24 14:00:25R11

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-17 Cont ID  
Sent By jgomez Date 2017-07-17 Time 11:54 Rev Time 0.00
Received By jgomez Date 2017-07-10 Time 10:27 Sent To  
Notes
2017-07-12 10:28:02RESUB ROUTED TO AWOOTEN VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-10 Cont ID  
Sent By jgomez Date 2017-07-10 Time 10:09 Rev Time 0.00
Received By jgomez Date 2017-06-07 Time 13:06 Sent To  
Notes
2017-06-08 13:06:34R42

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2017-08-28 Cont ID  
Sent By jgomez Date 2017-08-28 Time 10:33 Rev Time 0.00
Received By jgomez Date 2017-08-28 Time 10:33 Sent To  
Notes
2017-08-28 10:34:03NO FEES DUE. MU-2017-20578.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2017-07-17 Cont ID  
Sent By jgomez Date 2017-07-17 Time 11:42 Rev Time 0.00
Received By jgomez Date 2017-07-17 Time 11:42 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-07-10 Cont ID  
Sent By jgomez Date 2017-07-10 Time 09:18 Rev Time 0.00
Received By jgomez Date 2017-07-10 Time 07:53 Sent To  
Notes
2017-07-10 09:18:471- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE.
  

Review Stop M MECHANICAL (A/C)
Rev No 7 Status   Date 2018-01-19 Cont ID  
Sent By jgomez Date 2018-01-19 Time 10:10 Rev Time 0.00
Received By jgomez Date 2018-01-19 Time 09:24 Sent To  
Notes
2018-01-19 09:32:0901/19/18
 PRELIMINARY REVIEW DONE FOR JOE (ASTRO AIR INC) FOR A/C
 PERMIT (E-MAIL RECEIVED ON 01/18/18)
 -2014 FORM NOT 2017
 -CORRECT BUILDER NAME NOT THE A/C
 --NAME OF PREPARER AND SIGNATURE OF OWNER A THE BOTTOM
 OF PAGE ONE.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 6 Status N Date 2017-12-19 Cont ID  
Sent By jgomez Date 2017-12-19 Time 17:18 Rev Time 0.00
Received By jgomez Date 2017-12-19 Time 17:18 Sent To  
Notes
2017-12-19 17:20:3612/19/17 MET WITH KEVIN. HE SAID TO PROCESS PERMIT WITH
 MECHANICAL UNDER A SEPARATE PERMIT. JG.
  
  
  
 1) PROVIDE COMPLETE A/C PLANS AND EQUIPMENT SIZING
 CALCULATIONS UNDER A SEPARATE PERMIT.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2017-12-15 Cont ID  
Sent By jgomez Date 2017-12-15 Time 18:04 Rev Time 0.00
Received By jgomez Date 2017-12-15 Time 18:03 Sent To  
Notes
2017-12-15 18:06:25RESIDENTIAL (R3) ADDITION/ALTERATION FIFTH MECHANICAL
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE: ON PREVIOUS REVIEWS THE PROVISO OPTION WAS
 OFFERED. UNFORTUNATELY, RE-SUBMITTALS ARE RAISING MORE
 QUESTIONS THAN ANSWERS, THEREFORE DELAYING THE PERMIT
 PROCESS.
  
 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED
 ON THE BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION
 OF THE BUILDING AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY
 CONSERVATION.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 2- ARCHITECT OF RECORD TO SIGN AND SEAL BOTH A/C PLANS
 SUBMITTED AS REQUIRED BY CHAPTER 481 FLORIDA STATUTE
 WHEN SUBMITTING PLANS FOR PUBLIC RECORDS. NOTE: ONLY
 ONE COPY WAS SIGNED AT THIS TIME.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
  
 NOTE: CONTRACTOR MAY PROVIDE COMPLETE INFORMATION UNDER
 A SEPARATE MECHANICAL PERMIT. ADVICE IF THIS OPTION IS
 PREFERRED AT HIS TIME.
  
  
 *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2017-11-30 Cont ID  
Sent By jgomez Date 2017-11-30 Time 11:48 Rev Time 0.00
Received By jgomez Date 2017-11-30 Time 11:48 Sent To  
Notes
2017-11-29 08:01:56RESIDENTIAL (R3) ADDITION/ALTERATION FOURTH MECHANICAL
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO: PROVISO
 MEANS THAT CONTRACTOR MAY SUBMIT REQUIRED REVISED
 INFORMATION AFTER THE PERMIT IS ISSUED, BUT BEFORE ANY
 INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO
 ADVICE IF THE PROVISO OPTION IS PREFERRED AT THIS TIME.
 REVISION FEES APPLY IF INFORMATION IS SUBMITTED AFTER
 THE PERMIT IS ISSUED.
  
 NEW COMMENT:
 1- A) EQUIPMENT SIZE SPECIFIED ON THE A/C PLAN
 SUBMITTED DOESN'T MATCH EQUIPMENT SIZE SPECIFIED ON THE
 ENERGY CALCULATIONS SUBMITTED. REVISE AS REQUIRED TO
 MATCH. SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 B) EQUIPMENT SPECIFIED ON THE A/C PLAN SUBMITTED
 DOESN'T MATCH EQUIPMENT SPECIFIED ON THE EQUIPMENT
 SIZING CALCULATIONS SUBMITTED. REVISE AS REQUIRED TO
 MATCH. SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
  
 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED
 ON THE BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION
 OF THE BUILDING AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY
 CONSERVATION.
  
  
 3- ARCHITECT OF RECORD TO SIGN AND SEAL BOTH A/C PLANS
 SUBMITTED AS REQUIRED BY CHAPTER 481 FLORIDA STATUTE
 WHEN SUBMITTING PLANS FOR PUBLIC RECORDS. NOTE: ONLY
 ONE COPY WAS SIGNED AT THIS TIME.
  
  
 NOTE: CONTRACTOR MAY PROVIDE COMPLETE INFORMATION UNDER
 A SEPARATE MECHANICAL PERMIT. ADVICE IF THIS OPTION IS
 PREFERRED AT HIS TIME.
  
  
 *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2017-11-06 Cont ID  
Sent By jgomez Date 2017-11-06 Time 16:12 Rev Time 0.00
Received By jgomez Date 2017-11-06 Time 16:10 Sent To  
Notes
2017-11-06 16:12:05RESIDENTIAL (R3) ADDITION/ALTERATION THIRD MECHANICAL
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- PLANS SUBMITTED DON'T SHOW ANY MECHANICAL WORK, BUT
 A/C EQUIPMENT SIZING CALCULATIONS WERE SUBMITTED WITH
 THE ENERGY CALCULATIONS. CLARIFY IF DOING ANY
 MECHANICAL WORK. PROVIDE COMPLETE PLANS AND COMPLETE
 EQUIPMENT SIZING CALCULATIONS IF DOING ANY MECHANICAL
 WORK.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 NOTE: CONTRACTOR MAY PROVIDE COMPLETE INFORMATION UNDER
 A SEPARATE MECHANICAL PERMIT. ADVICE IF THIS OPTION IS
 PREFERRED AT HIS TIME.
  
 *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-10-03 Cont ID  
Sent By jgomez Date 2017-10-03 Time 15:30 Rev Time 0.00
Received By jgomez Date 2017-10-03 Time 15:29 Sent To  
Notes
2017-10-03 15:32:01RESIDENTIAL (R3) ADDITION/ALTERATION SECOND MECHANICAL
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- PLANS SUBMITTED DON'T SHOW ANY MECHANICAL WORK, BUT
 A/C EQUIPMENT SIZING CALCULATIONS WERE SUBMITTED WITH
 THE ENERGY CALCULATIONS. CLARIFY IF DOING ANY
 MECHANICAL WORK. PROVIDE COMPLETE PLANS AND COMPLETE
 EQUIPMENT SIZING CALCULATIONS IF DOING ANY MECHANICAL
 WORK.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 NOTE: CONTRACTOR MAY PROVIDE COMPLETE INFORMATION UNDER
 A SEPARATE MECHANICAL PERMIT. ADVICE IF THIS OPTION IS
 PREFERRED AT HIS TIME.
  
 *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-08-28 Cont ID  
Sent By jgomez Date 2017-08-28 Time 18:58 Rev Time 0.00
Received By jgomez Date 2017-08-28 Time 18:57 Sent To  
Notes
2017-08-28 19:01:51RESIDENTIAL (R3) ADDITION/ALTERATION MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- PLANS SUBMITTED DON'T SHOW ANY MECHANICAL WORK, BUT
 A/C EQUIPMENT SIZING CALCULATIONS WERE SUBMITTED WITH
 THE ENERGY CALCULATIONS. CLARIFY IF DOING ANY
 MECHANICAL WORK. PROVIDE COMPLETE PLANS AND COMPLETE
 EQUIPMENT SIZING CALCULATIONS IF DOING ANY MECHANICAL
 WORK.
  
 *****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2017-11-30 Cont ID  
Sent By jgomez Date 2017-11-30 Time 12:04 Rev Time 0.00
Received By jgomez Date 2017-11-30 Time 12:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2017-11-06 Cont ID  
Sent By jgomez Date 2017-11-06 Time 16:09 Rev Time 0.00
Received By jgomez Date 2017-11-06 Time 16:09 Sent To  
Notes
2017-11-06 11:44:18NEW PLANS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-10-03 Cont ID  
Sent By jgomez Date 2017-10-03 Time 15:24 Rev Time 0.00
Received By jgomez Date 2017-10-03 Time 15:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-08-29 Cont ID  
Sent By jgomez Date 2017-08-28 Time 18:56 Rev Time 0.00
Received By jgomez Date 2017-08-28 Time 18:56 Sent To  
Notes
2017-08-28 09:25:41REVISED DRAWINGS SUBMITTED. JG.
  
 RESIDENTIAL (R3) ADDITION/ALTERATION PLUMBING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- PLANS SUBMITTED NEED TO HAVE ARCHITECT'S ORIGINAL
 SEAL AND SIGNATURE. PERMIT APPLICATION AND PLANS
 SUBMITTED ARE HARD COPIES NOT DIGITAL SUBMITTAL. PLANS
 SUBMITTED SHOW A DIGITAL SIGNATURE. THIS IS NOT ALLOWED
 ON HARD COPIES SUBMITTAL. SEC. 481.221 F.S.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-06-23 Cont ID  
Sent By gjohnson Date 2017-06-23 Time 09:41 Rev Time 0.00
Received By gjohnson Date 2017-06-21 Time 15:44 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-11-06 Cont ID  
Sent By jgomez Date 2017-11-06 Time 16:06 Rev Time 0.00
Received By jgomez Date 2017-11-06 Time 16:06 Sent To  
Notes
2017-11-06 16:07:42ASPHALT SHINGLES FL18355-R2.

Review Stop Z ZONING
Rev No 6 Status P Date   Cont ID  
Sent By AW Date 2017-12-12 Time   Rev Time 0.00
Received By ajones Date 2017-12-06 Time 16:01 Sent To  
Notes
2017-11-28 16:09:47NEW DRAWINGS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 5 Status P Date   Cont ID  
Sent By   Date 2017-11-09 Time   Rev Time 0.00
Received By   Date 2017-11-08 Time   Sent To  
Notes
2017-11-06 11:43:49NEW PLANS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 4 Status P Date   Cont ID  
Sent By   Date 2017-10-05 Time   Rev Time 0.00
Received By   Date 2017-10-05 Time   Sent To  
Notes
2017-10-04 16:56:29ROUTED TO ALANA WOOTEN
2017-10-03 15:27:25NEW DRAWINGS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 3 Status F Date 2017-09-05 Cont ID  
Sent By awooten Date 2017-09-05 Time 09:56 Rev Time 0.00
Received By awooten Date 2017-09-05 Time   Sent To E
Notes
2017-09-05 09:49:35**************ZONING REVIEW
 FAILED***************************
  
 PLESE ADDRESS THE COMMENTS FROM PLUMBING ABOUT THE
 PLANS BEING SIGNED AND SEALED.
  
 THANKS,
 ALANA WOOTEN
 ASSOCIATE PLANNER
 ZONING
 561-822-1449
 [email protected]
2017-08-28 09:25:59REVISED DRAWINGS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2017-07-13 Time   Rev Time 0.00
Received By awooten Date 2017-07-13 Time 10:31 Sent To B
Notes
2017-07-12 16:45:36ROUTED TO ALANA WOOTEN

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2017-06-13 Time   Rev Time 0.00
Received By awooten Date 2017-06-13 Time 11:45 Sent To  
Notes
2017-06-14 11:23:22*****************ZONING
 REVIEW****************************
  
 ENCLOSING CARPORT--PLEASE SUBMIT SURVEY.
  
 PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS.
  
 THANKS,
 ALANA WOOTEN
 ASSOCIATE PLANNER
 [email protected]
 561-822-1449