2017-06-05 07:19:01 | 2014 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17060101 |
| ADD: 5050 BROADWAY |
| CONT: THERMA SEAL ROOFING |
| TEL: 561-223-2096 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: MON. JUNE 05/2017 |
| ACTION: DENIED |
| |
| 1) CONTRACTOR SUBMITTED FL2948-R-11 FLORIDA PRODUCT |
| APPROVAL MODIFIED BITUMEN ROOF SYSTEMS FOR A FLAT ROOF |
| APPROVAL. THE SUB-SYSTEM THAT WAS IDENTIFIED IS ON PAGE |
| 5 OF 52 SYSTEM NUMBER W-2. PLEASE NOTE THIS SYSTEM IS |
| GOOD FOR -45.0 WITH ASTERISK(*) ALLOWING FOR ENHANCED |
| FASTENING IN ZONES 2 & 3. |
| |
| FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING |
| SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF |
| ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF |
| ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. |
| FASTENER DENSITIES SHALL BE INCREASED FOR BOTH |
| INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE |
| WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION |
| PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED |
| PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. |
| 1609.6.4.4.1 COMPONENTS & CLADDING. |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |