Plan Review Details - Permit 17050872
Plan Review Stops For Permit 17050872
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-07-03 Cont ID  
Sent By cthroop Date 2017-07-03 Time 11:53 Rev Time 0.00
Received By cthroop Date 2017-07-03 Time 11:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-01 Cont ID  
Sent By cthroop Date 2017-06-01 Time 09:05 Rev Time 0.00
Received By cthroop Date 2017-06-01 Time 09:04 Sent To  
Notes
2017-06-01 09:08:26BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SIGNED AND SEALED WIND LOAD CALCULATIONS BY
 A REGISTERED FLORIDA ENGINEER PER EXISTING POLE DETAIL
 ON PLAN SHEET PHM-2.
  
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-06-01 Cont ID  
Sent By jleahy Date 2017-06-01 Time 08:22 Rev Time 0.00
Received By jleahy Date 2017-06-01 Time 08:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-03 Cont ID  
Sent By cthroop Date 2017-07-03 Time 11:53 Rev Time 0.00
Received By cthroop Date 2017-06-27 Time 13:11 Sent To  
Notes
2017-06-28 13:11:42RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-06-01 Cont ID  
Sent By cthroop Date 2017-06-01 Time 09:04 Rev Time 0.00
Received By cthroop Date 2017-05-18 Time 13:11 Sent To  
Notes
2017-05-19 13:11:17ROUTED TO ZONING

Review Stop Z ZONING
Rev No 1 Status P Date 2017-05-22 Cont ID  
Sent By jroach Date 2017-05-22 Time 13:01 Rev Time 0.00
Received By jroach Date 2017-05-22 Time 13:01 Sent To E
Notes
2017-05-19 17:05:19ROUTED TO JOHN ROACH