Plan Review Details - Permit 17050794
Plan Review Stops For Permit 17050794 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-06-09 |
Time |
18:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-06-09 |
Time |
17:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-05-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-05-24 |
Time |
06:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-05-23 |
Time |
18:41 |
Sent To |
|
|
Notes |
2017-05-24 07:16:10 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE NEW SINGLE HUNG WINDOW FOR OPENING NUMBER 3 DOES | | NOT MEET THE REQUIREMENTS OF FBC R310 FOR EMERGENCY AND | | RESCUE OPENINGS. INDICATE IF THERE IS ANOTHER OPENING | | IN THIS BEDROOM THAT MEETS THE REQUIREMENTS OF R310. IF | | THERE IS NO OTHER CODE COMPLIANT OPENING TO THE | | EXTERIOR IN THE BEDROOM, THEN INDICATE THE EXISTING | | WINDOW'S TYPE AND THE NET CLEAR OPENING SIZE OF IT. | | PROVIDE CALCULATIONS TO SHOW THAT THE NET CLEAR OPENING | | DIMENSIONS OF THE EXISTING WINDOW ARE NOT BEING REDUCED | | BY MORE THAN 5-PERCENT PER FBC EXISTING BUILDING | | SECTION 704.1. | | | | 2) INDICATE HOW AND WHERE THE MULLIONS WILL BE | | INSTALLED. FBC 107.2.1 | | | | 3) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | AND MAXIMUM DESIGN PRESSURES FOR THE IMPACT SLIDING | | GLASS DOOR. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-06-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-06-09 |
Time |
18:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-06-01 |
Time |
17:06 |
Sent To |
|
|
Notes |
2017-06-01 17:06:53 | RMCDOUGAL'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-05-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-05-24 |
Time |
06:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-05-17 |
Time |
10:45 |
Sent To |
|
|
Notes |
2017-05-18 10:45:38 | BLDG MISC 1 |
|
|
|