Plan Review Details - Permit 17050694
Plan Review Stops For Permit 17050694 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-07-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-07-05 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-07-05 |
Time |
11:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-05-26 |
Time |
07:04 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-05-26 |
Time |
07:04 |
Sent To |
FIRE |
|
Notes |
2017-05-26 07:13:34 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | FBC-107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | CONSTRUCTION DOCUMENTS - | | THE CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | REGISTERED DESIGN PROFESSIONAL | | WHERE REQUIRED BY CHAPTER 471, FLORIDA STATUTES& 61G15 | | FLORIDA ADMINISTRATIVE CODE | | OR CHAPTER 481, FLORIDA STATUTES& 61G1 FLORIDA | | ADMINISTRATIVE CODE, THEN HE OR SHE | | SHALL AFFIX HIS OR HER OFFICIAL SEAL TO SAID DRAWINGS, | | SPECIFICATIONS AND | | ACCOMPANYING DATA, AS REQUIRED BY FLORIDA STATUTE | | | | | | 471.003?QUALIFICATIONS FOR PRACTICE; EXEMPTIONS. | | | | (H)?ANY ELECTRICAL, PLUMBING, AIR-CONDITIONING, OR | | MECHANICAL CONTRACTOR WHOSE PRACTICE INCLUDES THE | | DESIGN | | AND FABRICATION OF ELECTRICAL, PLUMBING, | | AIR-CONDITIONING, OR MECHANICAL SYSTEMS, RESPECTIVELY, | | WHICH SHE OR HE | | INSTALLS BY VIRTUE OF A LICENSE ISSUED UNDER CHAPTER | | 489, UNDER PART I OF CHAPTER 553, OR UNDER ANY SPECIAL | | ACT | | OR ORDINANCE WHEN WORKING ON ANY CONSTRUCTION PROJECT | | WHICH: | | | | 1.? REQUIRES AN ELECTRICAL OR PLUMBING OR | | AIR-CONDITIONING AND REFRIGERATION SYSTEM WITH A VALUE | | OF $125,000 | | OR LESS; AND | | 2.A.?REQUIRES AN AGGREGATE SERVICE CAPACITY OF 600 | | AMPERES (240 VOLTS) OR LESS ON A RESIDENTIAL ELECTRICAL | | SYSTEM OR 800 AMPERES (240 VOLTS) OR LESS ON A | | COMMERCIAL OR INDUSTRIAL ELECTRICAL SYSTEM; | | | | PROVIDE 2 COPIES OF CUT SHEETS FOR THE GENERATOR AND | | TRANSFER SWITCH. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-06-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-06-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-06-30 |
Time |
10:16 |
Sent To |
E |
|
Notes |
2017-06-30 11:24:07 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) INSTALL, TEST AND INSPECT PER NFPA 110, STANDARD FOR | | EMERGENCY AND STANDBY POWER SYSTEMS, 2010 EDITION | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-05-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-05-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-05-30 |
Time |
11:48 |
Sent To |
PC |
|
Notes |
2017-05-30 13:29:24 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET E 1 - THERE ARE INCORRECT EDITIONS DATES | | REFERENCES TO THE FIRE CODES INDICATED. | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | APPLICABLE CODES OR STANDARDS. | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 13, 2010 EDITION. | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 72, 2010 EDITION. | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | | | | | 2) SHEET E 1 - THIS INSTALLATION APPEARS TO FUNCTION AS | | THE BACKUP TO THE LIFE SAFETY SYSTEMS. | | | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL COMPLY WITH | | NFPA 110, 2013 EDITION. | | | | PLEASE ENSURE COMPLIANCE AND PROVIDE AN APPLICABLE | | NOTE. | | | | | | | | 3) THE SCOPE OF WORK DOES NOT ADDRESS HOW LONG THE | | INSTALLTION WILL TAKE AND/OR FOR PROVIDING APPLICABLE | | ASSURANCES OF MAINTAINING THE EXISTING LIFE SAFETY | | PROTECTION. | | | | PLEASE PROVIDE. | | | | | | | | 4) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE | | DONE UNDER SEPARATE SHOP DRAWING BY CERTIFIED LIFE | | SAFETY CONTRACTORS. | | | | PLEASE PROVIDE AN APPLICABLE NOTE. | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-07-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-07-05 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-06-21 |
Time |
13:21 |
Sent To |
|
|
Notes |
2017-06-22 13:21:52 | RESUB ROUTED TO KMARTIN VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-06-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-06-22 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-05-15 |
Time |
08:30 |
Sent To |
|
|
Notes |
2017-05-16 08:30:33 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-06-29 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-06-29 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2017-06-29 |
Time |
13:51 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-05-23 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-05-23 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2017-05-23 |
Time |
10:30 |
Sent To |
E |
|
Notes |
2017-05-19 16:22:42 | ROUTED TO ERIC SCHNEIDER |
|
|
|
Account Summary | Usage Policy | Privacy Policy