Plan Review Details - Permit 17041240
Plan Review Stops For Permit 17041240
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-05 Cont ID  
Sent By jwitmer Date 2017-06-05 Time 09:38 Rev Time 0.00
Received By jwitmer Date 2017-06-05 Time 09:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-06 Cont ID  
Sent By jwitmer Date 2017-05-06 Time 09:58 Rev Time 0.00
Received By jwitmer Date 2017-05-06 Time 09:32 Sent To  
Notes
2017-05-06 09:58:512014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17041240
 ADD: 1645 PALM BEACH LAKES BLVD. SUITE # 600
 CONT: CHANDLER CONSTRUCTION
 TEL: 561-791-6934
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. MAY 06/2017
 ACTION: DENIED
  
 1) MISSING INFORMATION:
 1A) ONE SET OF PLANS IS MISSING SHEETS A5 THE FINISH
 FLOOR PLAN & A6 THE LIFE SAFETY PLAN. 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.
 1B) SHEET A6 THE OCCUPANCY LOAD IS NOT PROVIDED FOR
 THIS SPACE, TRAINING ROOMS ARE TO BE TAKEN AT 20 NET
 TABLE 1004.1.2 (EDUCATIONAL, LOOK AT THE USAGE OF
 TRAINING) .
 1C) SHEET A2 THE DIMENSIONAL FLOOR PLAN. IT APPEARS
 THAT THE HORIZONTAL DIMENSIONS (LEFT TO RIGHT) ARE
 MISSING FOR ROOMS 101 RECEPTION, 103 OFFICE & 104 CAF?.
 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-05-12 Cont ID  
Sent By jleahy Date 2017-05-12 Time 11:34 Rev Time 0.00
Received By jleahy Date 2017-05-12 Time 11:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-05-02 Cont ID  
Sent By scaldero Date 2017-05-02 Time 09:59 Rev Time 0.00
Received By scaldero Date 2017-05-02 Time 09:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-06-05 Cont ID  
Sent By jwitmer Date 2017-06-05 Time 09:38 Rev Time 0.00
Received By jwitmer Date 2017-06-01 Time 16:13 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-12 Cont ID  
Sent By jleahy Date 2017-05-12 Time 12:12 Rev Time 0.00
Received By jleahy Date 2017-04-27 Time 13:24 Sent To  
Notes
2017-04-28 13:24:40B06

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-05-06 Cont ID  
Sent By jwitmer Date 2017-05-06 Time 09:47 Rev Time 0.00
Received By jwitmer Date 2017-05-06 Time 09:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-06-01 Cont ID  
Sent By jwitmer Date 2017-06-05 Time 09:38 Rev Time 0.00
Received By ccole Date 2017-06-01 Time 17:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-05-02 Cont ID  
Sent By ccole Date 2017-05-02 Time 11:16 Rev Time 0.00
Received By ccole Date 2017-05-02 Time 11:16 Sent To  
Notes
2017-05-02 11:21:261ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17041240
 5/2/17
  
 1) REFER TO SECTIONS 809.1 & 809.2 FBC-14 EXISTING
 BUILDING CODE AND PROVIDE MINIMUM VENTILATION
 CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE 403.3
 FBC-14 MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES
 THE REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR.
  
 2) SHOW COMPLIANCE WITH C403.2.7.5 FBC-14 ENERGY
 CONSERVATION CODE FOR AIR DISTRIBUTION, AND DUCT SYSTEM
 SIZING.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-05-08 Cont ID  
Sent By gjohnson Date 2017-05-08 Time 16:28 Rev Time 0.00
Received By gjohnson Date 2017-05-08 Time 15:56 Sent To  
Notes
***NONE***