Plan Review Stops For Permit 17041233 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-08-02 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-08-02 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-08-01 |
Time |
09:27 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-05-26 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-05-26 |
Time |
08:16 |
Sent To |
|
|
Notes |
2017-05-26 09:40:41 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SEPERATE PERMIT REQUIRED FOR EACH STRUCTURE. | | 2. ALL SUBMITTAL DOCUMENTS SHALL BE SUBMITTED IN | | DUPLICATE. | | 3. PROVIDE GEOTECHNICAL SOILS REPORT FOR EACH BUILDING | | PAD. | | 4. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | 5. ROOFING PERMIT REQUIRED FOR EACH STRUCTURE. | | 6. PROVIDE NOA FOR ROOFING SYSTEM COMPONENTS | | (UNDERLAYMENT). | | 7. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | APPLICATION. | | | | R401.4 SOIL TESTS. | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | APPROVED METHOD. | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW MULLION | | SUBMITTALS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-09-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-09-19 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-09-19 |
Time |
14:38 |
Sent To |
|
|
Notes |
2017-09-19 14:08:13 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ATTACHED THE FOLLOWING ITEMS TO PLAN AS PROVISO: | | | | MAIN HOUSE: | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC | | RE3706.2, RE3902 | | 2. MAIN BREAKER REQUIRED AT SERVICE FOR EACH PANEL. | | PROVIDE CORRECTION. NEC 230.70(A); FBC RE 3601.6.2 | | 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. NEC 250.94; FBC RE3609.3 | | 4. SERVICE GROUNDING ELECTRODE TO BE AUGMENTED BY AN | | ADDITIONAL ELECTRODE 6 FEET AWAY OR PROVIDE EVIDENCE OF | | RESISTANCE TO GROUND OF 25 OHMS OR LESS. NEC 250.56; | | FBC RE 3608.4 | | 5. INCLUDE ALL GROUNDING ELECTRODES PRESENT TO BE | | BONDED AT SERVICE. NEC 250.50; FBC RE 3608.1 | | 6. SMOKE/CO ALARMS OUTSIDE OF BEDROOM SHOULD BE IN THE | | IMMEDIATE VICINITY OF THE SLEEPING ROOM AND INSTALLED | | AT THE HIGHEST POINT IN THE ROOM, AT LEAST 3 FEET FROM | | ANY MECHANICAL VENT OR CEILING FAN. PROVIDE CORRECTION. | | FBC RE 314.3; NFPA 72; 11.8.3.5 | | 7. LOAD CALCULATION FOR SERVICE SHOULD INCLUDE ALL | | LOADS, INCLUDING THE DETACHED GARAGE. A DISPOSAL IS NOT | | INCLUDED IN THE GENERAL LIGHTING LOAD. PROVIDE | | CORRECTED LOAD CALCULATION. NEC 220.82; FBC RE 3602.2 | | DETACHED GARAGE: | | 8. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC | | RE3706.2, RE3902 | | 9. PROVIDE GROUNDING ELECTRODE SYSTEM AT DETACHED | | GARAGE AS REQUIRED FOR A BUILDING OR STRUCTURE SUPPLIED | | BY A FEEDER OR BRANCH CIRCUIT. NEC 250.32; FBC RE3607.3 | | 10. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER FOR PANEL IN DETACHED GARAGE IN ADDITION | | TO THE MAIN BREAKER FEEDING THE PANEL. PANEL MUST BE | | SIZED FOR MAIN BREAKER FEEDING THIS PANEL FROM SERVICE. | | NEC 225.31, 225.32; FBC RE 3706.3 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-07-18 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-07-18 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-05-18 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-05-18 |
Time |
11:29 |
Sent To |
|
|
Notes |
2017-05-18 12:42:06 | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | ONLY ONE SET OF MAIN HOUSE PLANS JLEAHY |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-09-19 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-09-19 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2017-07-18 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-18 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-18 |
Time |
10:46 |
Sent To |
|
|
Notes |
2017-07-18 11:19:11 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. THE TANKLESS WATER HEATER ON DETACHED BUILDING IS | | NOT SHOWN ON GAS RISER DIAGRAM PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | | | 2. THE BTU LOAD FOR RANGE APPEARS A LITTLE LOW PLEASE | | PROVIDE MANUFACTURE SPECS FOR ALL THE GAS APPLIANCES TO | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | FBC-2014 FUEL GAS SEC. 402.2 | | | | 3. PROVIDE SIZING TABLES USED TO SIZE GAS SYSTEM. PER | | WPB AMEND TO FBC 107.2.1 | | | | 4. PLEASE SHOW SHUT OFF VALVES REGULATOR AND DRIP LEGS | | ON THE GAS RISER. PER WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2017-05-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-05-12 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-05-12 |
Time |
11:32 |
Sent To |
|
|
Notes |
2017-05-12 11:33:14 | GAS PLAN REVIEW | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | 107.2.1. | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | FBC-R, SEC. G2404.3. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2017-07-06 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-07-06 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-07-06 |
Time |
14:05 |
Sent To |
B |
|
Notes |
2017-07-06 14:06:40 | 7/6/2017 - REVISIONS MATCH HPB CONDITIONS FOR APPROVAL | | PER HPB CASE NO. 17-17. DLE |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2017-05-05 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-05-05 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-05-05 |
Time |
14:52 |
Sent To |
B |
|
Notes |
2017-05-05 14:57:49 | 5/5/2017 - PLANS NOT REVISED AFTER HPB (CASE NO. 17-17) | | GRANTED APPROVAL WITH CONDITIONS. REVISED PLANS SHOULD | | REFLECT 6/6-LIGHT SHS WINDOW CONFIGURATIONS (WITH | | SMALLER DIVISIONS FOR SMALLER OPENINGS), GABLE VENTS IN | | THE FRONT FACING GABLES TO THE EAST AND WEST (BUT NOT | | CENTER), REMOVAL OF STUCCO BANDING AROUND WINDOWS, AND | | CHANGE THE METAL BARREL TILE ROOFING MATERIAL TO MATCH | | THE PRODUCT APPROVALS FOR CLAY TILE. OTHERWISE, | | PROPOSED MATERIALS FOR CONSTRUCTION MATCH HPB-APPROVED | | PLANS. DLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-09-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-29 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-27 |
Time |
14:17 |
Sent To |
|
|
Notes |
2017-09-28 14:18:01 | RESUB ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-09-22 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-08-25 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-08-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-08-06 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-06-30 |
Time |
15:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-05-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-05-26 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-04-27 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2017-09-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-09-29 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-09-29 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-05-26 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-05-26 |
Time |
08:16 |
Sent To |
|
|
Notes |
2017-05-26 09:39:50 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
N |
Date |
2017-07-06 |
|
|
Cont ID |
|
Sent By |
rcaranci |
Date |
2017-07-06 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
rcaranci |
Date |
2017-07-06 |
Time |
16:56 |
Sent To |
|
|
Notes |
2017-07-06 16:56:43 | SEPARATE LANDSCAPE PERMIT IS REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-08-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-08-06 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-08-06 |
Time |
11:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-05-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-05-24 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-05-24 |
Time |
10:27 |
Sent To |
|
|
Notes |
2017-05-24 11:38:46 | PLAN DENIED | | ONLY ONE SET OF PLANS FOR MAIN HOUSE SUBMITTED | | TWO ARE REQUIRED. PER SECTION 107 FBC. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2017-09-19 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-09-19 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-09-19 |
Time |
15:31 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2017-07-18 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-18 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-18 |
Time |
09:57 |
Sent To |
|
|
Notes |
2017-07-18 10:46:34 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. A CLEANOUT IS REQUIRED ON THE BUILDING SEWER SERVING | | DETACHED BUILDING. PER FBC PL 708.3.5 | | | | 2. PLEASE PROVIDE A SITE PLAN SHOWING THE BUILDING | | DRAIN AND BUILDING SEWER INCLUDING CLEANOUTS. PER WPB | | AMEN TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-05-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-05-12 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-05-12 |
Time |
11:31 |
Sent To |
|
|
Notes |
2017-05-12 11:32:06 | IRRIGATION PLAN APPROVED | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-05-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-05-12 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-05-12 |
Time |
09:04 |
Sent To |
|
|
Notes |
2017-05-12 11:28:22 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. ON THE SANITARY RISER FOR DETACHED OFFICE THE SINK | | SHALL CONNECT TO BUILDING DRAIN SEPARATELY AND DOWN | | STREAM OF THE BATHROOM GROUP. FBC RES P3108.1 | | | | 2. PLEASE PROVIDE TWO COPY'S OF THE PLAN FOR THE MAIN | | HOUSE ONLY ONE WAS SUPPLIED WITH THE SUBMITTAL PACKAGE. | | WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2017-08-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-08-02 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-08-01 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-05-26 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-05-26 |
Time |
10:38 |
Sent To |
|
|
Notes |
2017-05-26 10:40:23 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOFING UNDERLAYMENT. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-09-01 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-09-01 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-09-01 |
Time |
13:31 |
Sent To |
B |
|
Notes |
2017-09-01 13:32:02 | 9/1/2017 - LANDSCAPE PERMIT SUBMITTED (#17081223). DLE |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2017-07-07 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-07-06 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-07-07 |
Time |
12:18 |
Sent To |
B |
|
Notes |
2017-07-06 14:07:38 | 7/7/2017 - NEW CONSTRUCTION APPLICANTS MUST SUBMIT A | | SEPARATE PERMIT FOR LANDSCAPING. PLEASE REMOVE | | LANDSCAPE PLANS IN CURRENT PERMIT AND SUBMIT | | SEPARATELY. ONCE SEPARATE LANDSCAPE PERMIT IS PULLED, | | THIS EXISTING PERMIT CAN PASS ZONING REVIEW. PLEASE | | DIRECT QUESTIONS TO RAY CARANCI, LANDSCAPE PLANNER AT | | 822-1462. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-05-05 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-05-05 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-05-05 |
Time |
14:52 |
Sent To |
B |
|
Notes |
2017-05-05 15:00:14 | 5/5/2017 - LANDSCAPE PLAN SHOULD BE SUBMITTED | | SEPARATELY UNDER A NEW PERMIT, PER RAY CARANCI, | | LANDSCAOPE PLANNER. DLE |
|
|