Plan Review Details - Permit 17041226
Plan Review Stops For Permit 17041226
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2017-07-18 Cont ID  
Sent By shill Date 2017-07-18 Time 15:45 Rev Time 0.00
Received By shill Date 2017-07-18 Time 15:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2017-07-11 Cont ID  
Sent By shill Date 2017-07-11 Time 16:27 Rev Time 0.00
Received By shill Date 2017-07-11 Time 16:27 Sent To  
Notes
2017-07-11 16:29:07BUILDING REVIEW WILL BE PASSED AFTER IMPACT FEE
 ASSESSMENT HAS BEEN COMPLETED.
 IMPACT FEE PLANS AND RECEIPT, IF APPLICABLE, MAY BE
 SENT VIA EMAIL OR MAY BE PROVIDED AS A RESUBMITTAL.
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-26 Cont ID  
Sent By shill Date 2017-06-26 Time 12:51 Rev Time 0.00
Received By shill Date 2017-06-26 Time 12:27 Sent To  
Notes
2017-06-26 12:51:58PROVISO - DRAINS IN THE ACCESSIBLE ROUTE ARE TO COMPLY
 WITH FBC 2014 ACCESSIBILITY A302.3.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-19 Cont ID  
Sent By shill Date 2017-05-19 Time 14:00 Rev Time 0.00
Received By shill Date 2017-05-16 Time 17:05 Sent To  
Notes
2017-05-19 14:04:49****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. PROVIDE A DETAIL FOR THE DRAINS LOCATED AT THE END
 OF THE ACCESS AISLE, A302 AND OTHER SHEETS. IF THE
 DRAIN HAS GRATES, REVISE PLANS TO NOTE GRATE
 ORIENTATION FBC A 302.3.
  
 2. FBC A 404.2.6, SHEET A311, REVISE PLAN TO SHOW
 DISTANCE BETWEEN DOORS 1102 AND 1102A (48" MIN.)
  
 3. FBC 107, PROVIDE A TOTAL OCCUPANT LOAD, TOTAL SF
 AREA, FOR THE BUILDING. A205 (AND POSSIBLY OTHER
 SHEETS) HAS A REVISED OCCUPANT LOAD AND SF AREA. THIS
 INFORMATION IS REQUIRED FOR CO.
  
 BUILDING INFORMATION SHOULD BE ON A SUMMARY PAGE, BUT
 IT DOES NOT APPEAR THAT THE PAGE WAS SUBMITTED; PLEASE
 UPDATE.
  
 4. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS
 REQUIRED DUE TO THE INCREASE IN SQUARE FOOT AREA. THE
 PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING FEES
 DUE, IF APPLICABLE, WERE PAID. 561-233-5025 FOR MORE
 INFORMATION.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-06-12 Cont ID  
Sent By jleahy Date 2017-05-24 Time 12:07 Rev Time 0.00
Received By jleahy Date 2017-05-24 Time 12:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-07-14 Cont ID  
Sent By pleduc Date 2017-07-14 Time   Rev Time 0.00
Received By pleduc Date 2017-06-21 Time 11:06 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-05-19 Cont ID  
Sent By pleduc Date 2017-05-19 Time   Rev Time 0.00
Received By pleduc Date 2017-05-19 Time 11:40 Sent To  
Notes
2017-05-19 13:52:08THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1 ) SHEET M201 - GENERATOR ROOM - IT APPEARS THAT THE
 DUCTING, INTAKE AND EXHAUST DOES NOT MEET THE
 REQUIRMENTS OF NFPA 110, EMERGENCY AND STANDBY POWER
 SYSTEMS. CHAPTER 7, INSTALLATION AND ENVIRONMENTAL
 CONSIDERATIONS
  
 THERE APPEARS TO BE A DAMPER WITHIN THE 2 HR INTERIOR
 WALL, RADIATOR INTAKE.
  
 7.7.2.1 FOR EPS SUPPLYING LEVEL 1 EPSS, VENTILATION AIR
 SHALL BE SUPPLIED DIRECTLY FROM A SOURCE OUTSIDE THE
 BUILDING BY AN EXTERIOR WALL OPENING OR FROM A SOURCE
 OUTSIDE THE BUILDING BY A 2-HOUR FIRE-RATED AIR
 TRANSFER SYSTEM.
 7.7.2.2 FOR EPS SUPPLYING LEVEL 1 EPSS, DISCHARGE AIR
 SHALL BE DIRECTED OUTSIDE THE BUILDING BY AN EXTERIOR
 WALL OPENING OR TO AN EXTERIOR OPENING BY A 2-HOUR
 FIRE-RATED AIR TRANSFER SYSTEM.
 7.7.2.3 FIRE DAMPERS, SHUTTERS, OR OTHER SELF-CLOSING
 DEVICES SHALL NOT BE PERMITTED IN VENTILATION OPENINGS
 OR DUCTWORK FOR SUPPLY OR RETURN/DISCHARGE AIR TO EPS
 EQUIPMENT FOR LEVEL 1 EPSS.
 7.7.3 VENTILATION AIR SUPPLY SHALL BE FROM OUTDOORS OR
 FROM A SOURCE OUTSIDE THE BUILDING BY AN EXTERIOR WALL
 OPENING OR FROM A SOURCE OUTSIDE THE BUILDING BY A
 2-HOUR FIRE-RATED AIR TRANSFER SYSTEM.
 7.7.4 VENTILATION AIR SHALL BE PROVIDED TO SUPPLY AND
 DISCHARGE COOLING AIR FOR RADIATOR COOLING OF THE EPS
 WHEN RUNNING AT RATED LOAD.
  
 7.7.4.1 VENTILATION AIR SUPPLY AND DISCHARGE FOR
 RADIATOR-COOLED EPS SHALL HAVE A MAXIMUM STATIC
 RESTRICTION OF 125 PA (0.5 IN. OF WATER COLUMN) IN THE
 DISCHARGE DUCT AT THE RADIATOR OUTLET.
  
 7.7.4.2 RADIATOR AIR DISCHARGE SHALL BE DUCTED OUTDOORS
 OR TO AN EXTERIOR OPENING BY A 2-HOUR RATED AIR
 TRANSFER SYSTEM.
  
 7.7.5 MOTOR-OPERATED DAMPERS, WHEN USED, SHALL BE
 SPRING OPERATED TO OPEN AND MOTOR CLOSED. FIRE DAMPERS,
 SHUTTERS, OR OTHER SELF-CLOSING DEVICES SHALL NOT BE
 PERMITTED IN VENTILATION OPENINGS OR DUCTWORK FOR
 SUPPLY OR RETURN/DISCHARGE AIR TO EPS EQUIPMENT FOR
 LEVEL 1 EPSS.
  
 PLEASE REVIEW, CLARIFY AND/OR CORRECT.
  
  
  
  
  
 2) SHEET M201 - GENERATOR ROOM - THERE APPEARS TO BE AN
 INTAKE FROM THE GENERATOR ROOM INTO THE THE FIRE PUMP
 ROOM THROUGH A RATED WALL.
  
 7.2 LOCATION.
 7.2.1 THE EPS SHALL BE INSTALLED IN A SEPARATE ROOM FOR
 LEVEL 1 INSTALLATIONS. EPSS EQUIPMENT SHALL BE
 PERMITTED TO BE INSTALLED IN THIS ROOM.
 7.2.1.1 THE ROOM SHALL HAVE A MINIMUM 2-HOUR FIRE
 RATING OR BE LOCATED IN AN ADEQUATE ENCLOSURE LOCATED
 OUTSIDE THE BUILDING CAPABLE OF RESISTING THE ENTRANCE
 OF SNOW OR RAIN AT A MAXIMUM WIND VELOCITY REQUIRED BY
 LOCAL BUILDING CODES.
 7.2.1.2 NO OTHER EQUIPMENT, INCLUDING ARCHITECTURAL
 APPURTENANCES, EXCEPT THOSE THAT SERVE THIS SPACE,
 SHALL BE PERMITTED IN THIS ROOM.
  
 THE PROPOSED IN NOT RELATED TO THE USE OF THE THIS ROOM
 OR ITS EQUIPMENT. PLEASE ALSO REVIEW/PROVIDE
 MANUFACTURES SPEC SHEETS FOR APPLICABLILITY.
  
 PLEASE REVIEW, CLARIFY AND/OR CORRECT.
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-17 Cont ID  
Sent By lmarchan Date 2017-07-17 Time 07:49 Rev Time 0.00
Received By lmarchan Date 2017-06-16 Time 08:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-06-09 Cont ID  
Sent By lmarchan Date 2017-06-09 Time 11:58 Rev Time 0.00
Received By lmarchan Date 2017-05-04 Time 15:34 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2017-07-18 Cont ID  
Sent By shill Date 2017-07-18 Time 15:46 Rev Time 0.00
Received By shill Date 2017-07-18 Time 15:46 Sent To  
Notes
2017-07-18 15:46:50LIFE SAFETY NUMBERS WERE CORRECTED; NO SQUARE FOOT AREA
 INCREASE
 LETTER FROM ARCHITECT RECEIVED VIA EMAIL.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-05-18 Cont ID  
Sent By shill Date 2017-05-18 Time 10:02 Rev Time 0.00
Received By shill Date 2017-05-18 Time 10:02 Sent To  
Notes
2017-05-18 10:03:19IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED
 DUE TO THE INCREASE IN SQUARE FOOT AREA. THE PLANS ARE
 TO BE STAMPED AND THE RECEIPT SHOWING FEES DUE WERE
 PAID (IF APPLICABLE) IS TO BE PROVIDED. 561-233-5025
 FOR MORE INFORMATION.
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-07-13 Cont ID  
Sent By ccole Date 2017-07-13 Time 12:49 Rev Time 0.00
Received By ccole Date 2017-07-13 Time 12:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-06-28 Cont ID  
Sent By ccole Date 2017-06-28 Time 13:36 Rev Time 0.00
Received By ccole Date 2017-06-28 Time 12:09 Sent To  
Notes
2017-06-28 13:41:31PROVISO:
  
 A REVISION TO THE PLANS MAY BE REQUIRED PER FIRE REVIEW
 COMMENT REGARDING THE LOCATION OF THE OUTSIDE AIR
 INTAKE OPENING IN THE GENERATOR ROOM/OPEN GARAGE COMMON
 WALL.
  
 CCOLE- 6/28/17

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-05-18 Cont ID  
Sent By ccole Date 2017-05-18 Time 12:37 Rev Time 0.00
Received By ccole Date 2017-05-17 Time 11:40 Sent To  
Notes
2017-05-18 12:37:371ST REVIEW FBC-2014 MECHANICAL
 REVISION PERMIT #17041226
 MASTER #16070715
 5/18/17
  
 RESULTS: DENIED
  
 PLEASE ADDRESS THE COMMENTS LISTED BELOW.
  
 1) SHEET M201: IN ACCORDANCE WITH SECTION 7.7.2.3 NFPA
 110, THE FIRE DAMPER CANNOT BE INSTALLED TO PROTECT THE
 O/A GENERATOR INTAKE OPENING.
  
 2) SHEETS M204, 206, 207, 210, 211, 212: PROVIDE A
 CALCULATION AND A MEANS OF PROVIDING OUTSIDE AIR TO THE
 NEW FCU'S SERVING THE NEW ELEVATOR LOBBIES.
  
 3) M206: A MINIMUM 10' CLEARANCE IS REQUIRED BETWEEN
 THE O/A INTAKE AND EXHAUST OPENINGS AT THE FPL VAULT.
 PLEASE VERIFY WITH MEASUREMENTS ON THE PLAN- SECTION
 401.4.
  
 4) M210: THE NEW CU-2-2 IS MISLABELED AS CU-2-3 ON THE
 EAST LINER ROOF.
  
 5) M212: PROVIDE AN FSD AT THE PENETRATION OF THE
 PRESSURIZATION DUCT AT STAIR #3.
  
 6) M213: SHOW THE 12X8 O/A DUCT DROP AND FSD PER NOTE
 #3. PROVIDE A SUBMITTAL FOR THE FIRE WRAP.
  
 7) M214: PROVIDE AN FSD SYMBOL AT THE 20X10 EXHAUST
 DUCT DROP PER NOTE #2 ON THE PLAN.
  
 8) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW FCU'S- SECTION C403.2.1 FBC-14 ENERGY CONSERVATION.
  
 9) REVISE THE ENERGY CALCULATIONS TO INCLUDE THE NEW
 FCU'S.
  
  
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-07-12 Cont ID  
Sent By tklarge Date 2017-06-29 Time 07:46 Rev Time 0.00
Received By tklarge Date 2017-06-29 Time 10:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-06-09 Cont ID  
Sent By tklarge Date 2017-06-09 Time 11:37 Rev Time 0.00
Received By tklarge Date 2017-05-22 Time 13:49 Sent To  
Notes
2017-06-09 11:17:211) SHT. P312B - THE GAS LINE CHANGES PIPE SIZE FROM 1
 1/4" TO 2" UP TO A FIRE PIT. SEE GAS LINE ON GRIDLINE
 E.0 BETWEEN GRIDLINE 12-13. CLARIFY. THIS DOES NOT
 CORRELATE WITH THE RISER ON SHT. P717.
 2) SHT. P312B - SHOWS AN 1 1/4 " GAS LINE SUPPLYING A
 2" GAS LINE UP TO A FIRE PIT. CLARIFY. REFER TO GAS
 LINE BETWEEN GRIDLINES F.1 - G AND 11 - 12. THIS DOES
 NOT CORRELATE WITH THE RISER ON SHT. P717.
 3) SHT. P312B - THERE IS AN 1 1/2" GAS LINE BEING FEED
 FROM A 2 1/2 " GAS LINE. SEE GRIDLINES 10 -11 ON A
 LINE. THIS DOES NOT CORRELATE WITH THE RISER ON SHT.
 P717.
 4) THE NARRATIVE STATES THAT FIRE PITS HAVE BEEN
 DELETED BUT THE GAS DRAWINGS STILL CALL OUT AND SHOWS
 GAS PIPING TO THE FIRE PITS. CLARIFY.
 5) SHT. P313B - THE NARRATIVE NOTES THAT THE NATURAL
 GAS TO THE FIRE PITS HAS BEEN DELETED AND GAS TO THE
 FIRE TABLES HAS BEEN ADDED BUT THE FIRE PITS ARE STILL
 NOTED/SHOWN ON THE PLANS AND THE FIRE TABLES ARE NOT
 SHOWN ON THE PLANS. CLARIFY.
 6) SHT. P717 - SHOW THE TOTAL DEVELOPED LENGTH FROM THE
 OUTLET OF THE GAS METER TO THE MOST REMOTE OUTLET ON
 THE SYSTEM.FBC-FUEL GAS SEC. 402.4.1.
 7) SHT. P717 - THE NARRATIVE FOR THIS SHEET NOTES THE
 DELETION OF GAS TO THE FIRE PITS AND ADDING GAS TO THE
 FIRE TABLES BUT THE FIRE PITS ARE STILL SHOWN ON THE
 GAS RISER AND THERE ARE NO FIRE TABLES SHOWN. CLARIFY.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2017-07-18 Cont ID  
Sent By shill Date 2017-07-18 Time 15:45 Rev Time 0.00
Received By shill Date 2017-07-18 Time 15:45 Sent To  
Notes
2017-07-13 12:52:453RD MECH REVIEW- NEW PLANS SHEETS- DIG/SIGS APPROVED.
 CCOLE- 7/13/17
2017-06-29 12:50:182ND REVIEW MECHANICAL PLANS DIG/SIGS REVIEWED AND
 VERIFIED- CCOLE- 6/29/17
2017-06-09 11:51:17DIGITAL SIGNATURE ON PLUMBING SHEETS VERIFIED.
 TKL.6/9/17.
2017-05-18 12:46:44MECHANICAL DIG/SIGS VERIFIED- CCOLE- 5/18/17
2017-05-16 15:43:576/26/17 L, A, AND S SHEETS DIGITAL SIGNATURES OK (SH)
 5/16/17 L, A, AND S SHEETS DIGITAL SIGNATURES OK (SH)
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2017-06-01 Cont ID  
Sent By aaponte Date 2017-06-01 Time 10:23 Rev Time 0.00
Received By aaponte Date 2017-06-01 Time 10:23 Sent To  
Notes
2017-06-01 10:24:25REVISIONS TO LANDSCAPE SHALL BE PROCESS THROUGH THE
 LANDSCAPE PERMIT.