Plan Review Details - Permit 17041105
Plan Review Stops For Permit 17041105
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-05-18 Cont ID  
Sent By shill Date 2017-05-18 Time 08:07 Rev Time 0.00
Received By shill Date 2017-05-18 Time 08:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-04-27 Cont ID  
Sent By jwitmer Date 2017-04-27 Time 07:01 Rev Time 0.00
Received By shill Date 2017-04-27 Time 07:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-04-28 Cont ID  
Sent By vperez Date 2017-04-28 Time 10:31 Rev Time 0.00
Received By vperez Date 2017-04-28 Time 10:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-05-19 Cont ID  
Sent By pleduc Date 2017-05-19 Time   Rev Time 0.00
Received By pleduc Date 2017-05-19 Time 14:03 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-05-01 Cont ID  
Sent By pleduc Date 2017-05-01 Time   Rev Time 0.00
Received By pleduc Date 2017-05-01 Time 12:35 Sent To  
Notes
2017-05-01 13:04:16THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET T - A NOTE UNDER THE PROJECT CODE TABULAR
 SECTION INDICATES A OCCUPANY GROUP B (BUSINESS) - SELF
 SERVICE LAUNDRY. THE APPLICATION AND SCOPE OF WORK
 INDICATES A WHITE BOX.
  
 PLEASE CORRECT TO BUSINESS OCCUPANCY ONLY.
  
  
  
  
 2) SHEET T - A NOTE UNDER THE LIFE SAFETY SECTION
 INDICATES A NA ON THE LINE FOR EXIT REMOTENESS. THE
 CODE REFERENCE PROVIDED . 101 7.5.1.3 APPEARS TO BE AN
 INACCURATE CODE REFERENCE.
  
 PER NFPA 101, CHAPTER 39, EXISTING BUSINESS OCCUPANCIES
  
 39.2.4 NUMBER OF MEANS OF EGRESS.
  
 39.2.4.1 MEANS OF EGRESS SHALL COMPLY WITH ALL OF THE
 FOLLOWING, EXCEPT AS OTHERWISE PERMITTED BY 39.2.4.2
 THROUGH 39.2.4.6:
 (1) THE NUMBER OF MEANS OF EGRESS SHALL BE IN
 ACCORDANCE WITH 7.4.1.1 AND 7.4.1.3 THROUGH 7.4.1.6.
 (2) NOT LESS THAN TWO SEPARATE EXITS SHALL BE PROVIDED
 ON EVERY STORY.
 (3) NOT LESS THAN TWO SEPARATE EXITS SHALL BE
 ACCESSIBLE FROM EVERY PART OF EVERY STORY.
  
 39.2.4.2 EXIT ACCESS, AS REQUIRED BY 39.2.4.1(3), SHALL
 BE PERMITTED TO INCLUDE A SINGLE EXIT ACCESS PATH FOR
 THE DISTANCES PERMITTED AS COMMON PATHS OF TRAVEL BY
 39.2.5.3.
  
 39.2.4.3 A SINGLE EXIT SHALL BE PERMITTED FOR A ROOM OR
 AREA WITH A TOTAL OCCUPANCY LOAD OF LESS THAN 100
 PERSONS PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE
 MET:
 (1) THE EXIT SHALL DISCHARGE DIRECTLY TO THE OUTSIDE AT
 THE LEVEL OF EXIT DISCHARGE FOR THE BUILDING.
 (2) THE TOTAL DISTANCE OF TRAVEL FROM ANY POINT,
 INCLUDING TRAVEL WITHIN THE EXIT, SHALL NOT EXCEED 100
 FT (30 M).
 (3) THE TOTAL DISTANCE OF TRAVEL SPECIFIED IN
 39.2.4.3(2) SHALL BE ON THE SAME STORY, OR, IF
 TRAVERSING OF STAIRS IS NECESSARY, SUCH STAIRS SHALL
 NOT EXCEED 15 FT (4570 MM) IN HEIGHT, AND BOTH OF THE
 FOLLOWING ALSO SHALL APPLY:
 (A) INTERIOR STAIRS SHALL BE PROVIDED WITH COMPLETE
 ENCLOSURES TO SEPARATE THEM FROM ANY OTHER PART OF THE
 BUILDING, WITH NO DOOR OPENINGS THEREIN.
 (B) A SINGLE OUTSIDE STAIR IN ACCORDANCE WITH 7.2.2
 SHALL BE PERMITTED TO SERVE ALL STORIES PERMITTED
 WITHIN THE 15 FT (4570 MM) VERTICAL TRAVEL LIMITATION.
  
 IF YOU BELIEVE YOUR OCCUPANCY MEETS ALL OF THE
 REQUIREMENTS PLEASE STATE IT AND CORRECT THE CODE
 REFERENCE.
  
  
  
  
 3) SHEET 1.0 & ALL OTHERS - THERE ARE NO DIMENSIONS
 PROVIDED ON ANY PLAN SHEET.
  
 PLEASE PROVIDE ACCURATE DIMENSION TO ALL AREAS.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2017-05-16 Time 15:05 Sent To  
Notes
2017-05-17 15:05:29B07

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-01 Cont ID  
Sent By gjohnson Date 2017-05-01 Time 18:24 Rev Time 0.00
Received By gjohnson Date 2017-04-25 Time 14:19 Sent To  
Notes
2017-04-26 14:17:10B08

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-05-23 Cont ID  
Sent By ccole Date 2017-05-23 Time 09:10 Rev Time 0.00
Received By ccole Date 2017-05-23 Time 09:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-05-01 Cont ID  
Sent By ccole Date 2017-05-01 Time 07:56 Rev Time 0.00
Received By ccole Date 2017-04-28 Time 17:08 Sent To  
Notes
2017-05-01 07:57:191ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17041105
 5/1/17
  
 1) PLEASE CLARIFY THE SCOPE OF WORK REGARDING THE
 AHU'S: DEMOLITON NOTE #1 ON SHEET M1.1 INDICATES THE
 UNITS ARE TO BE REMOVED, BUT THE CONDENSERS ON THE ROOF
 ARE TO REMAIN, AND THE ELECTRICAL PLANS ARE INDICATING
 THAT BOTH COMPONENTS ARE TO REMAIN.
  
 2) COVER SHEET T: CORRECT THE OCCUPANCY NOTE INDICATING
 "SELF-SERVICE LAUNDRY". THE PROJECT HAS BEEN CHANGED TO
 WHITE BOX.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-05-01 Cont ID  
Sent By tklarge Date 2017-05-01 Time 18:24 Rev Time 0.00
Received By gjohnson Date 2017-05-01 Time 15:28 Sent To  
Notes
***NONE***