Plan Review Details - Permit 17041097
Plan Review Stops For Permit 17041097
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-02 Cont ID  
Sent By shill Date 2017-05-02 Time 11:41 Rev Time 0.00
Received By shill Date 2017-05-02 Time 11:41 Sent To  
Notes
2017-05-02 11:54:11****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. SEE FIRE COMMENTS. A CHANGE OF OCCUPANCY IS REQUIRED
 PRIOR TO ISSUANCE OF AN EVENT PERMIT.
  
 SUBMIT AT THE BUILDING DIVISION:
  
 PERMIT APPLICATION
 PLANS WHICH SHOW EXISTING CONDITIONS
 PLANS WHICH SHOW PROPOSED IMPROVEMENTS WHICH ARE TO
 COMPLY WITH ALL REQUIREMENTS OF FBC 5TH EDITION
 EXISTING BUILDING CHAPTER 10 (CHANGE OF OCCUPANCY) AND
 ALTERATIONS AS APPLICABLE (LIKELY A LEVEL 2 ALTERATION)
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2017-05-04 Cont ID  
Sent By scaldero Date 2017-05-04 Time 15:43 Rev Time 0.00
Received By scaldero Date 2017-05-04 Time 15:40 Sent To  
Notes
2017-05-04 15:43:22PERMIT #17041097
  
 THIS OFFICE HAS REVIEWED THE INFORMATIO PROVIDED BY THE
 APPLICANT, VIA EMAIL, AS WELL AS THE INTENDED LOCATION
 (THE PARKING AREA BETWEEN THE TWO WAREHOUSES LISTED AS
 432 25TH STREET) . AT THIS TIME, OUR POSITION REMAINS
 UNCHANGED REGARDING THE DENIAL OF THE EVENT APPLICATION
 FOR NON-COMPLIANCE WITH THE REQUIREMENTS OF THE FLORIDA
 FIRE PREVENTION CODE FOR ASSEMBLY OCCUPANCIES, AS
 LISTED BELOW.
  
 PER NFPA 101, CHAPTER 12 - NEW ASSEMBLY OCCUPANCIES
 12.2.4.4 ?? A FENCED OUTDOOR ASSEMBLY OCCUPANCY SHALL
 HAVE NOT LESS THAN TWO REMOTE MEANS OF EGRESS FROM THE
 ENCLOSURE IN ACCORDANCE WITH 7.5.1.3.
 12.2.8 MEANS OF EGRESS, OTHER THAN FOR PRIVATE PARTY
 TENTS NOT EXCEEDING 1200 FT2, SHALL BE ILLUMINATED IN
 ACCORDANCE WITH SECTION 7.8.
 12.2.9.1 ?? EMERGENCY LIGHTING SHALL BE PROVIDED IN
 ACCORDANCE WITH SECTION 7.9.
  
 PER NFPA 101, CHAPTER 7 - MEANS OF EGRESS
 7.5.1.3.1 ?? WHERE MORE THAN ONE EXIT, EXIT ACCESS, OR
 EXIT DISCHARGE IS REQUIRED FROM A BUILDING OR PORTION
 THEREOF, SUCH EXITS, EXIT ACCESSES, OR EXIT DISCHARGES
 SHALL BE REMOTELY LOCATED FROM EACH OTHER AND BE
 ARRANGED TO MINIMIZE THE POSSIBILITY THAT MORE THAN ONE
 HAS THE POTENTIAL TO BE BLOCKED BY ANY ONE FIRE OR
 OTHER EMERGENCY CONDITION.
 7.5.1.3.2* ?? WHERE TWO EXITS, EXIT ACCESSES, OR EXIT
 DISCHARGES ARE REQUIRED, THEY SHALL BE LOCATED AT A
 DISTANCE FROM ONE ANOTHER NOT LESS THAN ONE-HALF THE
 LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE
 BUILDING OR AREA TO BE SERVED, MEASURED IN A STRAIGHT
 LINE BETWEEN THE NEAREST EDGE OF THE EXITS, EXIT
 ACCESSES, OR EXIT DISCHARGES, UNLESS OTHERWISE PROVIDED
 IN 7.5.1.3.3 THROUGH 7.5.1.3.5.
  
 ADDITIONALLY, THE FOLLOWING QUESTIONS AND/OR DETAILS
 HAVE NOT BEEN ADDRESSED BY NEITHER THE SUBMITTED HAND
 DRAWING NOR THE EMAIL BELOW.
  
 1) HOW WILL THE OCCUPANT LOAD OF 250 PERSONS (AS
 PROVIDED IN THE APPLICATION BY THE APPLICANT) BE
 ENFORCED?
  
 2) ASSEMBLY OCCUPANCIES ARE REQUIRED TO HAVE ONE
 PROPERLY TRAINED (1) CROWD MANAGER FOR EVERY 250
 PERSONS.
  
 3) THE INFORMATION BELOW, AS WELL AS THE DRAWING
 SUBMITTED WITH THE INITIAL APPLICATION INDICATES THAT
 THIS PROPERTY HAS 2 DOORS AND/OR GATES AT THE FRONT OF
 THE PROPERTY. A REVIEW OF THE PROPERTY SHOWS 1 MANUAL
 GATE DOOR, APPROXIMATELY, 10-15 FEET IN WIDTH. THE
 DETAILS PROVIDED ARE INACCURATE.
  
 4) WILL THERE BE ANY ACCESS TO THE INTERIOR OF THE
 NEIGHBORING WAREHOUSE SPACES BY STAFF OR THE GENERAL
 PUBLIC? HOW WILL THIS BE MONITORED?
  
 5) HOW IS THE ELECTRICAL SERVICE TO THE MUSIC STAGE AND
 THE FOOD TENT BEING SUPPLIED?
  
 6) THE FOOD TENT IS LABELED AS "FINGER FOODS".
 ADDITIONAL DETAILS REQUIRED? WILL THERE BE ANY COOKING
 AND/OR WARMING OF FOODS? IF SO, HOW WILL THIS BE
 ACCOMPLISHED?
  
 7) EMERGENCY NOTIFICATION IS REQUIRED, EVEN FOR OUTDOOR
 EVENTS. HOW WILL THIS BE ACCOMPLISHED IN A MANNER THAT
 IS IMMEDIATE, EFFICIENT, AND EFFECTIVE FOR THIS TYPE OF
 EVENT?
  
 8) DETAILS REGARDING QUANTITY AND LOCATION OF FIRE
 EXTINGUISHERS HAS NOT BEEN PROVIDED.
  
  
 SUE ELLEN CALDERON
 ASST. FIRE MARSHAL
 WPBFR
 [email protected]
 561-804-4751

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-04-27 Cont ID  
Sent By scaldero Date 2017-04-27 Time 14:42 Rev Time 0.00
Received By scaldero Date 2017-04-27 Time 14:36 Sent To  
Notes
2017-04-27 14:42:08PERMIT # 17041097
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 REVIEW FAILED COMMENTS:
  
 1) PROPERTY IS A WAREHOUSE AND NOT APPROVED FOR USE AS
 AN ASSEMBLY SPACE. A CHANGE OF USE REQUEST/APPLICATION
 IS REQUIRED.
  
 2) NOT ENOUGH DETAILS HAVE BEEN PROVIDED TO DETERMINE
 COMPLIANCE WITH NFPA REQUIREMENTS FOR ASSEMBLY
 OCCUPANCIES.
  
 3) PROPERTY SHALL COMPLY WITH ALL NFPA REQUIREMENTS, TO
 INCLUDE NFPA 101, CHAPTER 12 - NEW ASSEMBLY
 OCCUPANCIES.
  
 4) IT IS UNKNOWN IF THE PROPERTY IS EQUIPPED WITH ANY
 LIFE SAFETY SYSTEMS, TO INCLUDE A FIRE ALARM SYSTEM
 AND/OR A FIRE SPRINKLER SYSTEM.
  
 5) EMERGENCY EXITING PROVIDED IN DRAWING DOES NOT
 APPEAR TO COMPLY WITH NFPA 1 AND NFPA 101 REQUIREMENTS
 FOR THE NUMBER OF EXPECTED ATTENDEES.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-02 Cont ID  
Sent By ajones Date 2017-05-02 Time 15:21 Rev Time 0.00
Received By ajones Date 2017-04-27 Time 10:20 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-05-02 Cont ID  
Sent By ajones Date 2017-05-02 Time 15:21 Rev Time 0.00
Received By ajones Date 2017-05-02 Time 15:21 Sent To  
Notes
2017-05-02 15:21:505/2/17- FAILED ADDRESS FIRE AND BUILDING COMMENTS