Plan Review Stops For Permit 17041058 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-06-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-05 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-05 |
Time |
10:08 |
Sent To |
|
|
Notes |
2017-06-05 10:44:03 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17041058 | | ADD: 525 S. FLAGLER DR. SUITE # 18C | | CONT: BUTLER | | TEL: 561-832-9700 | | E-MAIL: | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MON. JUNE 05/ 2017 | | ACTION: BUILDING PROVISO | | | | BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B | | 2014) | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-05-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-05 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-05-05 |
Time |
10:23 |
Sent To |
|
|
Notes |
2017-05-05 10:36:54 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17041058 | | ADD: 525 S. FLAGLER DR. SUITE # 18C | | CONT: BUTLER | | TEL: 561-832-9700 | | E-MAIL: ??????????????? | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. MAY 05/ 2017 | | ACTION: DENIED | | | | 1) THE PLANS MAY BE DRAWN TO AT LEAST 1/8 INCH SCALE | | BUT THE WORDING IS TOO SMALL TO BE LEGIBLE WHEN | | SCANNING IN FOR RECORD RETENTION. | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.2.1.4 QUALITY OF BUILDING PLANS. | | BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH | | SCALE. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | OTHER ITEMS RELATED TO RECORDS MANAGEMENT. | | | | 2) THE DESIGNER OF RECORD NEEDS TO ADD THEIR LICENSE | | NUMBER TO THE PLANS THEY HAVE CREATED. | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.3.4 DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE. | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-06-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-06-22 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-06-22 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-06-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-06-07 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-06-07 |
Time |
08:56 |
Sent To |
|
|
Notes |
2017-06-07 09:13:08 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | ELECTRICAL REVIEW COMMENTS: | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW. ELECTRICAL PLAN | | REQUIRED TO BE SIGNED BY ELECTRICAL QUALIFIER OR DESIGN | | PROFESSIONAL. FBC 107.3.5, FS 471.003(2)(H), 471.025 | | 2. PROVIDE FLOOR PLAN INDICATING LOCATION OF REQUIRED | | SMOKE ALARMS. IF NONE ARE EXISTING, OR NOT TO CODE, | | SHOW AS NEW INSTALLATION. FBC 907.2.11 | | 3. PROVIDE LOCATION ON PLAN OF ALL OUTLETS IN KITCHEN | | PER CODE. SHOW AS EXISTING OR NEW AS REQUIRED. NEC | | 210.52 | | 4. PROVIDE PANEL SCHEDULE, INDICATE ANY NEW OR ALTERED | | CIRCUITS, AFCI OR GFCI PROTECTION WHERE APPLICABLE. NEC | | 408.4, 210.8, 210.12(B) | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-05-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-05-08 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-05-08 |
Time |
14:53 |
Sent To |
|
|
Notes |
2017-05-08 14:55:02 | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | COMPLY WITH FIRE DEPT COMMENTS. | | IF YOU ARE RELOCATING OR DELETING ITEMS PLEASE NOTE ON | | DRAWINGS |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-06-05 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-06-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-06-05 |
Time |
11:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-04-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-04-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-04-27 |
Time |
09:49 |
Sent To |
|
|
Notes |
2017-04-27 14:55:08 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) THE IS NO TITLE BLOCK ON THE SUBMITTED SHEET THAT | | INCLUDE THE ADDRESS, APT # AND DESIGN PROFESSIONAL. | | | | PLEASE CORRECT. | | | | | | | | | | 2) THE PRINT IS TOO SMALL AND UNREADABLE IN SOME AREAS. | | | | PLEASE ENLARGE | | | | | | | | | | 3) THERE IS APPEARS TO WALLS BEING REMOVED AND CEILING | | WORK PROPOSED IN THE KITCHEN AREA. | | | | IT IS UNCLEAR WHAT IS EXSITING AND WHAT IS NEW. | | | | PLEASE CLARIFY OR PROVIDE BETTER DETAIL. | | | | | | | | | | 4) ANY REMOVAL OR CONSTRUCTION OF NEW WALLS OR CEILING | | SPACES REQUIRES AN EVALUATION OF THE FIRE SPRINKLER | | COVERAGE AND PROTECTION. THERE IS NO INDICATION OF | | EXISTING SPRINKLERS OR ANY WORK BEING DONE. | | | | ANY FIRE SPRINKLER OR FIRE ALARM WORK SHALL BE DONE | | UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | CONTRACTORS. | | | | PLEASE PROVIDE AN APPLICABLE NOTE OF ALL APPLICABLE | | INFORMATION AND COMPLIANCE. | | | | | | | | | | 5) THERE APPEAR TO BE BE NEW WORK IN THE BATHROOM | | CEILING AREA. | | | | IT IS UNCLEAR WHAT IS EXSITING AND WHAT IS NEW. | | | | PLEASE CLARIFY OR PROVIDE BETTER DETAIL. | | | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-06-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-06-22 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-06-20 |
Time |
12:56 |
Sent To |
|
|
Notes |
2017-06-21 12:56:39 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-06-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-06-13 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-01 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-05-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-05-08 |
Time |
07:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-24 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2017-05-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-05 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-05-05 |
Time |
10:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2017-08-28 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-08-28 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-08-28 |
Time |
16:17 |
Sent To |
|
|
Notes |
2017-08-28 16:17:25 | ROUTE TO ME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-06-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-06-13 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-13 |
Time |
12:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-05-08 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-05-08 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-05-08 |
Time |
08:09 |
Sent To |
|
|
Notes |
2017-05-08 09:33:13 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. PLEASE COMPLY WITH BUILDING AND FIRES COMMENTS. PER | | WPB AMEND TO FBC 107.2.1 | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|