Plan Review Details - Permit 17040865
Plan Review Stops For Permit 17040865 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-07-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-07-14 |
Time |
06:42 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-07-14 |
Time |
06:17 |
Sent To |
|
|
Notes |
2017-07-24 15:42:36 | 7/24/2017 RAMP SUBMITTED UNDER PERMIT 17070240 PASSED | | BY C. TROOP MAKING A ACCESSIBLE FRONT ENTRY AND SAME | | PATH TO THE RECEPTIONIST. JW. | 2017-07-14 06:44:13 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17040865 | | ADD: 101 N. CLEMATIS ST. SUITE: 110 | | CONT: TBD TO BE DETERMINED | | TEL: [email protected] | | E-MAIL: 954-914-9848 | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: FRI. JULY 14/ 2017 | | ACTION: DENIED. | | | | 1E) REQUESTED AS A DEFERRED SUBMITTAL. SHEET A-110.00 | | SHOWS A PROPOSED NEW ACCESSIBLE RAMP LOCATION THAT WILL | | SATISFY BOTH COMMENTS 1E & COMMENT 2. THIS RAMP | | LOCATION WILL ALSO NEED ZONING APPROVAL. THE DESIGNER | | OF RECORD HAS NOT MET THE ZONING REQUIREMENT THAT THE | | RAMP HAS NOT MET THE MINIMUM 16 FOOT SETBACK AS | | MEASURED FROM THE BACK OF THE EXISTING CURB ALONG | | CLEMATIS ST. | | | | 1F) PLEASE NOTE THE PROPOSED RAMP DESIGN WILL NEED TO | | SHOW COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE | | 405.7.4 CHANGE IN DIRECTION. | | 405.7.4 CHANGE IN DIRECTION. RAMPS THAT CHANGE | | DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR | | LANDING 60 INCHES (1525 MM) MINIMUM BY 60 INCHES (1525 | | MM) MINIMUM. | | | | 1ST ROUND OF COMMENTS. EGRESS REQUIREMENTS INDICATE (2) | | ARE REQUIRED AND 4 ARE PROVIDED. IN THE SCOPING | | REQUIREMENTS CHAPTER 2 OF THE ACCESS. CODE SECTION | | 206.4.1. PUBLIC ENTRANCES. IN ADDITION TO ENTRANCES | | REQUIRED BY 206.4.2 THROUGH 206.4.9, AT LEAST 60 | | PERCENT OF ALL PUBLIC ENTRANCES SHALL COMPLY WITH 404. | | BARRIERS AT COMMON OR EMERGENCY ENTRANCES AND EXITS OF | | BUSINESS ESTABLISHMENTS CONDUCTING BUSINESS WITH THE | | GENERAL PUBLIC THAT ARE EXISTING, UNDER CONSTRUCTION, | | OR UNDER CONTRACT FOR CONSTRUCTION WHICH WOULD PREVENT | | A PERSON FROM USING SUCH ENTRANCES OR EXITS SHALL BE | | REMOVED. PLEASE NOTE IN SPEAKING WITH THE BUILDING | | OFFICIAL WE ARE CONSIDERING THE FRONT ENTRY DOORS AS | | ONE ENTRANCE, 3 X 0.6 = 1.8 OR (2) ACCESSIBLE MEANS OF | | EGRESS ARE REQUIRED, PLEASE SHOW ON THE PLANS . | | | | 2) NOT SATISFIED UNTIL COMMENT (1E) IS SATISFIED. SHEET | | A-110.00 PLEASE REVIEW THE LAYOUT OF THE FRONT ENTRY, | | RECEPTION AND WAITING AREAS AND SHOW HOW COMPLIANCE | | WITH SECTION 206.3 OF THE ACCESS. CODE IS TO BE | | COMPLIED WITH. 206.3 LOCATION. | | ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN | | THE SAME AREA AS GENERAL CIRCULATION PATHS. WHERE | | CIRCULATION PATHS ARE INTERIOR, REQUIRED ACCESSIBLE | | ROUTES SHALL ALSO BE INTERIOR. | | ADVISORY 206.3 LOCATION. THE ACCESSIBLE ROUTE MUST BE | | IN THE SAME AREA AS THE GENERAL CIRCULATION PATH. THIS | | MEANS THAT CIRCULATION PATHS, SUCH AS VEHICULAR WAYS | | DESIGNED FOR PEDESTRIAN TRAFFIC, WALKS, AND UNPAVED | | PATHS THAT ARE DESIGNED TO BE ROUTINELY USED BY | | PEDESTRIANS MUST BE ACCESSIBLE OR HAVE AN ACCESSIBLE | | ROUTE NEARBY. ADDITIONALLY, ACCESSIBLE VERTICAL | | INTERIOR CIRCULATION MUST BE IN THE SAME AREA AS STAIRS | | AND ESCALATORS, NOT ISOLATED IN THE BACK OF THE | | FACILITY. | | | | 3) COMPLIED. | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-06-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-23 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-23 |
Time |
06:58 |
Sent To |
|
|
Notes |
2017-06-23 08:38:06 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17040865 | | ADD: 101 N. CLEMATIS ST. SUITE: 110 | | CONT: TBD TO BE DETERMINED | | TEL: [email protected] | | E-MAIL: 954-914-9848 | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: FRI. JUNE 23/ 2017 | | ACTION: BUILDING PROVISO/ PLANS TO BE STAMPED AFTER | | ZONING APPROVAL. | | | | 1) BUILDING PROVISO: COMMENT 1E) REQUESTED AS A | | DEFERRED SUBMITTAL. SHEET A-110.00 SHOWS A PROPOSED NEW | | ACCESSIBLE RAMP LOCATION THAT WILL SATISFY BOTH | | COMMENTS 1E & COMMENT 2. THIS RAMP LOCATION WILL ALSO | | NEED ZONING APPROVAL. PLEASE NOTE THE PROPOSED RAMP | | DESIGN WILL NEED TO SHOW COMPLIANCE WITH 2014 | | FBC-ACCESSIBILITY CODE 405.7.4 CHANGE IN DIRECTION. | | 405.7.4 CHANGE IN DIRECTION. RAMPS THAT CHANGE | | DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR | | LANDING 60 INCHES (1525 MM) MINIMUM BY 60 INCHES (1525 | | MM) MINIMUM. | | | | 1ST ROUND OF COMMENTS. EGRESS REQUIREMENTS INDICATE (2) | | ARE REQUIRED AND 4 ARE PROVIDED. IN THE SCOPING | | REQUIREMENTS CHAPTER 2 OF THE ACCESS. CODE SECTION | | 206.4.1. PUBLIC ENTRANCES. IN ADDITION TO ENTRANCES | | REQUIRED BY 206.4.2 THROUGH 206.4.9, AT LEAST 60 | | PERCENT OF ALL PUBLIC ENTRANCES SHALL COMPLY WITH 404. | | BARRIERS AT COMMON OR EMERGENCY ENTRANCES AND EXITS OF | | BUSINESS ESTABLISHMENTS CONDUCTING BUSINESS WITH THE | | GENERAL PUBLIC THAT ARE EXISTING, UNDER CONSTRUCTION, | | OR UNDER CONTRACT FOR CONSTRUCTION WHICH WOULD PREVENT | | A PERSON FROM USING SUCH ENTRANCES OR EXITS SHALL BE | | REMOVED. PLEASE NOTE IN SPEAKING WITH THE BUILDING | | OFFICIAL WE ARE CONSIDERING THE FRONT ENTRY DOORS AS | | ONE ENTRANCE, 3 X 0.6 = 1.8 OR (2) ACCESSIBLE MEANS OF | | EGRESS ARE REQUIRED, PLEASE SHOW ON THE PLANS . | | | | 2) BUILDING PROVISO: NOT SATISFIED UNTIL COMMENT (1E) | | IS SATISFIED. SHEET A-110.00 PLEASE REVIEW THE LAYOUT | | OF THE FRONT ENTRY, RECEPTION AND WAITING AREAS AND | | SHOW HOW COMPLIANCE WITH SECTION 206.3 OF THE ACCESS. | | CODE IS TO BE COMPLIED WITH. 206.3 LOCATION. | | ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN | | THE SAME AREA AS GENERAL CIRCULATION PATHS. WHERE | | CIRCULATION PATHS ARE INTERIOR, REQUIRED ACCESSIBLE | | ROUTES SHALL ALSO BE INTERIOR. | | ADVISORY 206.3 LOCATION. THE ACCESSIBLE ROUTE MUST BE | | IN THE SAME AREA AS THE GENERAL CIRCULATION PATH. THIS | | MEANS THAT CIRCULATION PATHS, SUCH AS VEHICULAR WAYS | | DESIGNED FOR PEDESTRIAN TRAFFIC, WALKS, AND UNPAVED | | PATHS THAT ARE DESIGNED TO BE ROUTINELY USED BY | | PEDESTRIANS MUST BE ACCESSIBLE OR HAVE AN ACCESSIBLE | | ROUTE NEARBY. ADDITIONALLY, ACCESSIBLE VERTICAL | | INTERIOR CIRCULATION MUST BE IN THE SAME AREA AS STAIRS | | AND ESCALATORS, NOT ISOLATED IN THE BACK OF THE | | FACILITY. | | | | 3) COMPLIED. | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-05-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-15 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-05-15 |
Time |
10:00 |
Sent To |
|
|
Notes |
2017-05-15 14:00:53 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17040865 | | ADD: 101 N. CLEMATIS ST. SUITE: 110 | | CONT: TBD TO BE DETERMINED | | TEL: [email protected] | | E-MAIL: 954-914-9848 | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MON. MAY 15/ 2017 | | ACTION: DENIED | | | | 1) THE SHEET G-0400.00 CODE SUMMARY SHEET: | | 1A) UNDER THE HEADING APPLICABLE CODES, MISSING THE 5TH | | EDITION OF THE FLORIDA EXISTING BUILDING CODE. | | | | 1B) THE DESIGNER OF RECORD HAS NOT INDICATED UNDER THE | | 2014 EXISTING BUILDING CODE WHICH COMPLIANCE METHOD WAS | | USED IN DEVELOPING THE PLANS. EXISTING BLDG. CODE THE | | CHANGE OF OCCUPANCY OF ALL EXISTING BUILDINGS SHALL | | COMPLY WITH ONE OF THE METHODS LISTED IN SECTIONS | | 301.1.1 THROUGH 301.1.3 AS SELECTED BY THE APPLICANT. | | FOR THIS REVIEW THE BUILDING PLAN REVIEWER WILL USE THE | | WORK AREA METHOD SINCE 99 % OF ALL DESIGNERS USE THIS | | DESIGN METHOD FOR ALTERATIONS, CHANGE OF OCCUPANCY, | | ADDITION OR RELOCATION OF EXISTING BUILDINGS. CHANGE OF | | OCCUPANCY, 2014 FBC-EXISTING BUILDING CODE CHAPTER 10. | | 1001.3.1 PARTIAL CHANGE OF OCCUPANCY CLASSIFICATION. | | WHERE A PORTION OF AN EXISTING BUILDING IS CHANGED TO A | | NEW OCCUPANCY CLASSIFICATION, SECTION 1012 SHALL APPLY. | | | | 1C) UNDER THE HEADING OF OCCUPANCY TYPE: THE PLANS | | INDICATE BUSINESS. PLEASE PROVIDE A MORE DESCRIPTIVE | | USE OF THIS SPACE TO DETERMINE IF THIS TENANT IS TO BE | | CLASSIFIED AS A GENERAL DOCTORS OFFICE, OR SPECIALIZING | | IN THE TREATMENT OF CONDITIONS THAT AFFECT MOBILITY OR | | ONE OF THE SPECIALTY OCCUPANCIES FOUND UNDER CHAPTER 4 | | OF THE FBC-B. | | | | 1D) UNDER THE HEADING CONSTRUCTION TYPE THE PLANS STATE | | CONFIRM AND CODE SECTION, THIS SECTION IS NOT FOUND IN | | EITHER THE 2014 FBC-B NOR EXISTING BUILDING CODE. THE | | OTHER ISSUE WITH TRYING TO IDENTIFY A BUILDING | | CONSTRUCTION TYPE WE CAN GO TO FBC-B TABLE 601 FIRE | | RESISTANCE RATINGS BUT THE RATINGS DO NOT MATCH ANY OF | | THE BUILDING TYPES. THE CLOSEST IS A BUILDING TYPE | | CONSTRUCTION IA BUT MORE RESTRICTIVE WITH 3 HOUR FIRE | | RATING ON THE EXTERIOR BEARING WALLS. 107.2.1.3 | | ADDITIONAL INFORMATION IS REQUIRED. | | | | 1E) EGRESS REQUIREMENTS INDICATE (2) ARE REQUIRED AND 4 | | ARE PROVIDED. IN THE SCOPING REQUIREMENTS CHAPTER 2 OF | | THE ACCESS. CODE SECTION 206.4.1. PUBLIC ENTRANCES. IN | | ADDITION TO ENTRANCES REQUIRED BY 206.4.2 THROUGH | | 206.4.9, AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES | | SHALL COMPLY WITH 404. BARRIERS AT COMMON OR EMERGENCY | | ENTRANCES AND EXITS OF BUSINESS ESTABLISHMENTS | | CONDUCTING BUSINESS WITH THE GENERAL PUBLIC THAT ARE | | EXISTING, UNDER CONSTRUCTION, OR UNDER CONTRACT FOR | | CONSTRUCTION WHICH WOULD PREVENT A PERSON FROM USING | | SUCH ENTRANCES OR EXITS SHALL BE REMOVED. PLEASE NOTE | | IN SPEAKING WITH THE BUILDING OFFICIAL WE ARE | | CONSIDERING THE FRONT ENTRY DOORS AS ONE ENTRANCE, 3 X | | 0.6 = 1.8 OR (2) ACCESSIBLE MEANS OF EGRESS ARE | | REQUIRED, PLEASE SHOW ON THE PLANS . | | 2) SHEET A-110.00 PLEASE REVIEW THE LAYOUT OF THE FRONT | | ENTRY, RECEPTION AND WAITING AREAS AND SHOW HOW | | COMPLIANCE WITH SECTION 206.3 OF THE ACCESS. CODE IS TO | | BE COMPLIED WITH. 206.3 LOCATION. | | ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN | | THE SAME AREA AS GENERAL CIRCULATION PATHS. WHERE | | CIRCULATION PATHS ARE INTERIOR, REQUIRED ACCESSIBLE | | ROUTES SHALL ALSO BE INTERIOR. | | | | ADVISORY 206.3 LOCATION. THE ACCESSIBLE ROUTE MUST BE | | IN THE SAME AREA AS THE GENERAL CIRCULATION PATH. THIS | | MEANS THAT CIRCULATION PATHS, SUCH AS VEHICULAR WAYS | | DESIGNED FOR PEDESTRIAN TRAFFIC, WALKS, AND UNPAVED | | PATHS THAT ARE DESIGNED TO BE ROUTINELY USED BY | | PEDESTRIANS MUST BE ACCESSIBLE OR HAVE AN ACCESSIBLE | | ROUTE NEARBY. ADDITIONALLY, ACCESSIBLE VERTICAL | | INTERIOR CIRCULATION MUST BE IN THE SAME AREA AS STAIRS | | AND ESCALATORS, NOT ISOLATED IN THE BACK OF THE | | FACILITY. | | | | 3) DISCREPANCY IN PLANS SHEET S-301 DETAIL # 5 | | INDICATING THE NEW ROOF TOP A/C UNIT TO SIT ON A NEW | | W4X13 BEAM PER THE MANUFACTURERS REQUIREMENT. THE PLANS | | SHOW THE NEW BEAM TO BE WELDED TO AN EXISTING BEAM. THE | | M1.2 NOTE # 1 INDICATES THE NEW ROOF TOP UNIT IS TO SIT | | ON TOP OF A NOA APPROVED ROOF RACK TO BE DESIGNED BY | | THE STRUCTURAL ENGINEER? 107.2.1.3 ADDITIONAL | | INFORMATION IS REQUIRED. | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-07-21 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-07-21 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-07-21 |
Time |
07:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-06-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-06-23 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-06-23 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-05-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-05-23 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-05-23 |
Time |
10:37 |
Sent To |
|
|
Notes |
2017-05-23 11:06:46 | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | 1ST REVIEW: FBC 2014 | | | | PAGE E0.1, E1.1, E1.2 | | | | NEED A REFERENCE TO NEC CODE SECTION 517.13(B)(C) FOR | | INSULATED EQUIPMENT GROUNDING IN PATIENT CARE AREAS | | FOR ALL WIRING IN THESE AREASUP TO7-1/2' FROM THE | | FLOOR. | | | | PAGE E0.2 RISER DIAGRAM | | | | PROVIDE THE FAULT CURRENT CALCULATION FOR ALL NEW | | PANELS "H", "LA", "LB", AND "IDF" PER 110.24 (A)(B) |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-07-12 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-07-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-07-11 |
Time |
15:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-06-16 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-06-16 |
Time |
09:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-04-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-04-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-04-27 |
Time |
09:46 |
Sent To |
|
|
Notes |
2017-04-27 11:21:21 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) SHEET G 010.00 - THE SUITE # (110) IS NOT INDICATED | | IN THE TITLE BLOCK. | | | | THE PROPER ADDRESS IS REQUIRED IN THE TITLE BLOCK. | | PLEASE CORRECT. | | | | | | | | 2) SHEET G 030.00 - THE OCCUPANCY IS INDICATED AS | | BUSINESS; HOWEVER, THERE IS NO SCOPE PROVIDED FOR THE | | SERVICES PROVIDED. | | | | 3.3.188.1* AMBULATORY HEALTH CARE OCCUPANCY. AN | | OCCUPANCY USED TO PROVIDE SERVICES OR TREATMENT | | SIMULTANEOUSLY TO FOUR OR MORE PATIENTS THAT PROVIDES, | | ON AN OUTPATIENT BASIS, ONE OR MORE OF THE FOLLOWING: | | (1) TREATMENT FOR PATIENTS THAT RENDERS THE PATIENTS | | INCAPABLE OF TAKING ACTION FOR SELFPRESERVATION UNDER | | EMERGENCY CONDITIONS WITHOUT THE ASSISTANCE OF OTHERS; | | (2) ANESTHESIA THAT RENDERS THE PATIENTS INCAPABLE OF | | TAKING ACTION FOR SELF-PRESERVATION UNDER EMERGENCY | | CONDITIONS WITHOUT THE ASSISTANCE OF OTHERS; (3) | | EMERGENCY OR URGENT CARE FOR PATIENTS WHO, DUE TO THE | | NATURE OF THEIR INJURY OR ILLNESS, ARE INCAPABLE OF | | TAKING ACTION FOR SELF-PRESERVATION UNDER EMERGENCY | | CONDITIONS WITHOUT THE ASSISTANCE OF OTHERS. | | | | 6.1.6 AMBULATORY HEALTH CARE. FOR REQUIREMENTS, SEE | | CHAPTERS 20 AND 21. | | 6.1.6.1* DEFINITION ? AMBULATORY HEALTH CARE OCCUPANCY. | | AN OCCUPANCY USED TO PROVIDE SERVICES OR TREATMENT | | SIMULTANEOUSLY TO FOUR OR MORE PATIENTS THAT PROVIDES, | | ON AN OUTPATIENT BASIS, ONE OR MORE OF THE FOLLOWING: | | (1) TREATMENT FOR PATIENTS THAT RENDERS THE PATIENTS | | INCAPABLE OF TAKING ACTION FOR SELF-PRESERVATION UNDER | | EMERGENCY CONDITIONS WITHOUT THE ASSISTANCE OF OTHERS | | (2) ANESTHESIA THAT RENDERS THE PATIENTS INCAPABLE OF | | TAKING ACTION FOR SELF-PRESERVATION UNDER EMERGENCY | | CONDITIONS WITHOUT THE ASSISTANCE OF OTHERS | | (3) EMERGENCY OR URGENT CARE FOR PATIENTS WHO, DUE TO | | THE NATURE OF THEIR INJURY OR ILLNESS, ARE INCAPABLE OF | | TAKING ACTION FOR SELF-PRESERVATION UNDER EMERGENCY | | CONDITIONS WITHOUT THE ASSISTANCE OF OTHERS | | | | A.6.1.6.1 AMBULATORY HEALTH CARE OCCUPANCY. IT IS NOT | | THE INTENT THAT OCCUPANTS BE CONSIDERED TO BE INCAPABLE | | OF SELFPRESERVATION JUST BECAUSE THEY ARE IN A | | WHEELCHAIR OR USE ASSISTIVEWALKING DEVICES, SUCH AS A | | CANE, A WALKER, OR CRUTCHES. | | RATHER, IT IS THE INTENT TO ADDRESS EMERGENCY CARE | | CENTERS THAT RECEIVE PATIENTS WHO HAVE BEEN RENDERED | | INCAPABLE OF SELFPRESERVATION DUE TO THE EMERGENCY, | | SUCH AS BEING RENDERED UNCONSCIOUS AS A RESULT OF AN | | ACCIDENT OR BEING UNABLE TO MOVE DUE TO SUDDEN ILLNESS. | | | | 6.1.11.1* DEFINITION ? BUSINESS OCCUPANCY. AN OCCUPANCY | | USED FOR THE TRANSACTION OF BUSINESS OTHER THAN | | MERCANTILE. | | A.6.1.11.1 BUSINESS OCCUPANCY. BUSINESS OCCUPANCIES | | INCLUDE THE FOLLOWING: | | (1) AIR TRAFFIC CONTROL TOWERS (ATCTS) | | (2) CITY HALLS | | (3) COLLEGE AND UNIVERSITY INSTRUCTIONAL BUILDINGS, | | CLASSROOMS UNDER 50 PERSONS, AND INSTRUCTIONAL | | LABORATORIES | | (4) COURTHOUSES | | (5) DENTISTS? OFFICES | | (6) DOCTORS? OFFICES | | (7) GENERAL OFFICES | | (8) OUTPATIENT CLINICS (AMBULATORY) | | (9) TOWN HALLS | | | | PLEASE PROVIDE A DETAILED DESCRIPTION OF THE SERVICES | | PROVIDED TO ENSURE APPLICABLE OCCUPANCY CLASSIFICATION. | | | | | | | | | | 3) SHEET A 110.00 & A 610.00 - THE IT ROOM DOOR, A-11 | | IS INDICATED AS BEING RATED, HOWEVER, THE WALLS OF THE | | IT ROOM ARE NOT. THIS IS CONFUSING. | | | | PLEASE REVIEW, CORRECT OR CLARIFY. | | | | | | | | 4) SHEET M 1.1 - IF THE IT ROOM DOOR AND WALLS ARE | | PROPOSED TO BE RATED, THE A/C VENT DUCT IS REQUIRED TO | | BE PROVIDED WITH A FIRE OR SMOKE DAMPER ? | | | | PLEASE REVIEW, CORRECT OR CLARIFY. | | | | | | | | 5) SHEET A 610.00 - THE DOOR SCHEDULE INDICATES NUMERIC | | HARDWARE SETS. A HARDWARE SET TABLE COULD NOT BE | | READIDLY LOCATED. | | | | PLEASE PROVIDE THE APPLICABLE TABLE AND ENSURE | | COMPLIANCE WITH NFPA 101, CHAPTER 7, MEANS OF EGRESS | | AND/OR THE APPLICABLE OCCUPANCY CHAPTER FOR ALL OTHER | | DOORS. | | | | | | | | 6) SHEET A 130.00 - THERE ARE NO NOTES OR MAUNUFACTURES | | SPECIFICATION SHEETS INDICATING COMPLIANCE WITH THE | | INTERIOR FINISH RATINGS PER THE APPLICABLE OCCUPACNY | | CHAPTER. | | | | PER NFPA 101, CHAPTER 38, NEW BUSINESS OCCUPANCIES | | 38.3.3 INTERIOR FINISH. | | 38.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN | | ACCORDANCE WITH SECTION 10.2. | | 38.3.3.2 INTERIOR WALL AND CEILING FINISH. | | 38.3.3.2.1 INTERIOR WALL AND CEILING FINISH MATERIAL | | COMPLYING WITH SECTION 10.2 SHALL BE CLASS A OR CLASS B | | IN EXITS AND IN EXIT ACCESS CORRIDORS. | | 38.3.3.2.2 INTERIOR WALL AND CEILING FINISHES SHALL BE | | CLASS A, CLASS B, OR CLASS C IN AREAS OTHER THAN THOSE | | SPECIFIED IN 38.3.3.2.1. | | 38.3.3.3 INTERIOR FLOOR FINISH. | | 38.3.3.3.1 INTERIOR FLOOR FINISH SHALL COMPLY WITH | | SECTION 10.2. | | 38.3.3.3.2 INTERIOR FLOOR FINISH IN EXIT ENCLOSURES | | SHALL BE CLASS I OR CLASS II. | | 38.3.3.3.3 INTERIOR FLOOR FINISH SHALL COMPLY WITH | | 10.2.7.1 OR 10.2.7.2, AS APPLICABLE. | | | | | | PLEASE PROVIDE ALL APPLICABLE NOTES OR SPEC SHHETS IN | | COMPLIANCE WITH THE ABOVE CODE OR OTHER APPLICABLE CODE | | PER # 1 ABOVE. | | | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-07-31 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-07-31 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-07-07 |
Time |
13:26 |
Sent To |
|
|
Notes |
2017-07-28 15:32:40 | TO CAROLINE FOR PROCESSING. | 2017-07-10 13:27:02 | C33 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-07-10 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-06-29 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-06-13 |
Time |
13:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-06-05 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-06-05 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-04-19 |
Time |
13:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2017-05-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-15 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-05-15 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2017-07-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-07-19 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-07-19 |
Time |
09:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-06-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-06-20 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-06-20 |
Time |
14:19 |
Sent To |
|
|
Notes |
2017-06-20 15:15:30 | | | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #17040865 | | 6/20/17 | | | | COMMENT #6 FROM THE 1ST REVIEW STILL EXISTS. I HAVE | | REPRINTED IT BELOW. IF THE INTENTION IS TO MODIFIY THE | | EXISTING SUPPORT STRUCTURE ON THE ROOF TO SUPPORT THE | | NEW CONDENSER, PLEASE PROVIDE COMPLETE DETAILS AND EDIT | | THE NOTE ON M3.0 THAT IS SPECIFYING A NEW STAND. | | | | 6) THE ARCHITECTURAL AND STRUCTURAL PLANS ARE | | CONFLICTING WITH THE MECHANICAL PLAN AS TO HOW THE NEW | | ACCU-1 WILL BE MOUNTED ON THE ROOF- SEE A-111.00, | | S-301, AND M3.0. IF USING THE STAND, PLEASE PROVIDE TWO | | COPIES OF THE NOA BEARING THE APPROVAL STAMP OF THE | | EOR. THE EOR SHALL ALSO CIRCLE, HIGHLIGHT, OR OTHERWISE | | MARK ALL APPLICABLE NOTES, DETAILS, FASTENERS , AND | | DESIGN | | | | PRESSURE TABLES ETC.THAT PERTAIN TO THE INSTALLATION. | | SEE ALSO TABLE 1509.6.5 FBC-14 BUILDING AND SHOW THE | | CLEARANCE HEIGHT FROM THE ROOM SURFACE TO THE BOTTOM OF | | THE CU. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-04-25 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-04-25 |
Time |
07:26 |
Sent To |
|
|
Notes |
2017-04-25 11:50:19 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17040865 | | 4/25/17 | | | | 1) SHEET G-040.00: THE PROPOSED PROJECT IS CLASSIFIED | | AS A CHANGE OF OCCUPANCY AS DEFINED BY SECTION 202 | | FBC-14 EXISTING BUILDING CODE. PLEASE ADD THE REQUIRED | | CODE DATA TO THE GENERAL PROJECT INFORMATION. | | | | 2) REVISE THE ENERGY CALCULATIONS TO INDICATE CHANGE OF | | OCCUPANCY UNDER BUILDING CLASSIFICATION. | | | | 3) M0.1: PROVIDE EXHAUST VENTILATION CALCULATIONS FOR | | THE TOILET ROOMS AND THE ELECTRICAL AND SOILED ROOMS. | | PLEASE INDICATE HOW THE FANS WILL OPERATE- CONTINUOSLY | | OR INTERMITTENTLY. | | | | 4) SHEET M1.1: IT APPEARS RETURN GRILLS ARE MISSING IN | | THE CEILINGS OF OFFICES # 25, 26, 27, 32, 33 & STAFF | | LOUNGE #41. | | | | 5) M1.1: PLEASE LABEL THE CONDENSER SHOWN IN THE 2ND | | FLOOR PLAN. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR | | THE CONDENSER THAT INDICATE IT CAN BE INSTALLED ON THE | | INTERIOR OF THE BUILDING. | | | | 6) THE ARCHITECTURAL AND STRUCTURAL PLANS ARE | | CONFLICTING WITH THE MECHANICAL PLAN AS TO HOW THE NEW | | ACCU-1 WILL BE MOUNTED ON THE ROOF- SEE A-111.00, | | S-301, AND M3.0. IF USING THE STAND, PLEASE PROVIDE TWO | | COPIES OF THE NOA BEARING THE APPROVAL STAMP OF THE | | EOR. THE EOR SHALL ALSO CIRCLE, HIGHLIGHT, OR OTHERWISE | | MARK ALL APPLICABLE NOTES, DETAILS, FASTENERS , AND | | DESIGN | | | | PRESSURE TABLES ETC.THAT PERTAIN TO THE INSTALLATION. | | SEE ALSO TABLE 1509.6.5 FBC-14 BUILDING AND SHOW THE | | CLEARANCE HEIGHT FROM THE ROOM SURFACE TO THE BOTTOM OF | | THE CU. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-07-20 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-20 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-20 |
Time |
06:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-06-21 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-21 |
Time |
08:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-05-17 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-05-17 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-05-17 |
Time |
15:51 |
Sent To |
|
|
Notes |
2017-05-17 16:40:45 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. SHOW KNEE AND TOE CLEARANCE FOR LAVATORY. PER FBC | | ACC 606.2 | | | | 2. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | POSITION, 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 | | MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP | | OF THE GRIPPING SURFACE. PER FBC ACC 609.4 | | | | 3. ROOM 28 P-TLT THE TOP FOR THE LAVATORY CAN NOT | | ENCROACH INTO THE CLEAR FLOOR SPACE OF THE TOILET. PER | | FBC ACC 604.3.1, 604.3.2, | | | | 4. SHT. P0.1 DETAIL P1 A VACUUM RELIEF VALVE IS | | REQUIRED ON A BOTTOM FED WATER HEATER .PER FBC PL 504.2 | | | | 5. THE BREAKROOM SINK, THE SINK IN THE WAITING ROOM AND | | A MIN OF ONE SINK IN ONE OF THE EXAM ROOMS SHALL COMPLY | | WITH FBC ACC 606, 212.3 SINKS. | | WHERE SINKS ARE PROVIDED, AT LEAST 5 PERCENT, BUT NO | | FEWER THAN ONE, OF EACH TYPE PROVIDED IN EACH | | ACCESSIBLE ROOM OR SPACE SHALL COMPLY WITH 606. | | | | 6. THE WATER FOUNTAIN SHALL COMPLY WITH FBC ACC 602. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-07-28 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2017-07-28 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2017-07-28 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2017-06-29 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2017-06-29 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2017-06-29 |
Time |
15:21 |
Sent To |
|
|
Notes |
2017-06-29 15:25:42 | COMMENT ON PREVIOUS REVIEW HAS NOT BEEN ADDRESSED. SEE | | BELOW. | | COMMENT DATED 6/1/17 :PLEASE INCLUDE A DRAWING | | INDICATING THE PROPOSEDL OFFICE FRONTAGE ALONG CLEMATIS | | STREET, AND ITS PERCENTAGE IN RELATION TO THE ENTIRE | | BUILDING FRONTAGE TO CONFIRM COMPLIANCE WITH THE | | MINIMUM RETAIL ACTIVE USE FRONTAGE (SEE TABLE IV:25 FOR | | PERCENTAGE REQUIRED) | | PLEASE CONTACT ANA MARIA APONTE AT 561-822-1439 FOR | | FURTHER INFORMATION. | | | | IF RAMP IS PROPOSED ALONG SIDEWALK PLEASE INCLUDE | | INFORMATION TO CONFIRM COMPLIANCE WITH MINIMUM 16' | | SETBACKS AS MEASURED FROM BACK OF EXISTING CURB ALONG | | CLEMATIS STREET. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-06-01 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2017-06-01 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2017-06-01 |
Time |
14:19 |
Sent To |
|
|
Notes |
2017-06-01 14:24:22 | PLEASE INCLUDE A DRAWING INDICATING THE PROPOSEDL | | OFFICE FRONTAGE ALONG CLEMATIS STREET, AND ITS | | PERCENTAGE IN RELATION TO THE ENTIRE BUILDING FRONTAGE | | TO CONFIRM COMPLIANCE WITH THE MINIMUM RETAIL ACTIVE | | USE FRONTAGE (SEE TABLE IV:25 FOR PERCENTAGE REQUIRED) |
|
|
|