Plan Review Details - Permit 17040656
Plan Review Stops For Permit 17040656
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-05-22 Cont ID  
Sent By jwitmer Date 2017-05-22 Time 15:22 Rev Time 0.00
Received By jwitmer Date 2017-05-22 Time 15:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-04-20 Cont ID  
Sent By jwitmer Date 2017-04-20 Time 13:53 Rev Time  
Received By jwitmer Date 2017-04-20 Time   Sent To  
Notes
2017-04-20 13:53:29BUILDING PLAN REVIEW
 W. P. B. REVISION: 17040656
 W. P. B. PERMIT: 16070262
 ADD: 6501 S. DIXIE HWY. SUITE # 103
 CONT: RESTORATION OF THE PALM BEACHES CGC060332
 TEL: 561-891-8163
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. APRIL 23/ 2017
 ACTION: DENIED
  
 1) THE SUBMITTED REVISION TO THE PLAN WAS NOT DRAWN BY
 THE DESIGNER OF RECORD P. E. JOE SPASOVSKI # 76217 WHO
 IS THE DESIGNER OF RECORD. PLEASE PROVIDE DOCUMENTATION
 FOR SUCCESSOR ENGINEER UNDER 61G15-27.001(2) FOR
 ENGINEERS AND OR 61G1-18.002 PROCEDURES FOR A SUCCESSOR
 ARCHITECT.
 IN THE TITLEBLOCK ZIAJA INTERNATIONAL ASSOCIATES
 ARCHITECTURAL MANAGEMENT WHICH IS ACTING AS AN
 ARCHITECT BY USING THE WORD ARCHITECT IN THE FICTITIOUS
 NAME IT APPEARS THAT YOU ARE ADVERTISING AS BEING A
 LICENSED ARCHITECT. EXCEPTIONS . THE EXCEPTION BELOW
 DOES ALLOW FOR OTHER THAN A ARCHITECT FOR BUILDINGS
 LESS THAN $25,000 DOLLARS IN VALUE. THIS IS ANOTHER
 ISSUE THE PICTURES TAKEN FORM THE JOBSITE VISIT APPEAR
 TO BE MORE WORK THAN STATED IN THE PERMIT APPLICATION
 AND THE SCOPE OF WORK.
 481.229 EXEMPTIONS TO LICENSURE (1) ( C ) ANY OTHER
 TYPE OF BUILDING COSTING LESS THAN $25,000, EXCEPT A
 SCHOOL, AUDITORIUM, OR OTHER BUILDING INTENDED FOR
 PUBLIC USE, PROVIDED THAT THE SERVICES OF A REGISTERED
 ARCHITECT SHALL NOT BE REQUIRED FOR MINOR SCHOOL
 PROJECTS PURSUANT TO S. 1013.45.
  
 NO MEP PLANS WERE SUBMITTED AND WOULD NEED TO BE
 UPDATED SINCE THERE IS A REVISION TO THE ORIGINAL
 BUILDING CONFIGURATION. 2014 FLORIDA BUILDING CODE W
 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.3.5.1.1 MINIMUM
 REQUIREMENTS FOR COMMERCIAL BUILDING PLAN REVIEWS.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. / WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-05-22 Cont ID  
Sent By jleahy Date 2017-05-22 Time 13:14 Rev Time 0.00
Received By jleahy Date 2017-05-22 Time 13:14 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-04-25 Cont ID  
Sent By vperez Date 2017-04-25 Time 09:17 Rev Time 0.00
Received By vperez Date 2017-04-25 Time 09:17 Sent To  
Notes
2017-04-25 09:19:19PER CONVERSATION WITH CONTRACTOR, THESE PLANS SUBMITTED
 ARE TO BE VIODED AS THEY DO NOT REFLECT SCOPE OF WORK.
 CONTRACTOR IS SUBMITTING NEW SET. NO ADDITIONAL REVIEWS
 ARE TO BE PERFORMED UNDER THIS PERMIT
  
 V. PEREZ
 *6717

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status N Date 2017-05-22 Cont ID  
Sent By wjolin Date 2017-05-22 Time 15:23 Rev Time 0.00
Received By jwitmer Date 2017-05-22 Time 15:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2017-04-25 Cont ID  
Sent By wjolin Date 2017-04-25 Time 09:19 Rev Time 0.00
Received By vperez Date 2017-04-25 Time 09:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-05-22 Cont ID  
Sent By jwitmer Date 2017-05-22 Time 15:23 Rev Time 0.00
Received By jwitmer Date 2017-05-11 Time 09:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-04-25 Cont ID  
Sent By vperez Date 2017-04-25 Time 09:19 Rev Time 0.00
Received By vperez Date 2017-04-25 Time 09:19 Sent To  
Notes
2017-04-25 09:20:37PER CONVERSATION WITH CONTRACTOR, THESE PLANS SUBMITTED
 ARE TO BE VIODED AS THEY DO NOT REFLECT SCOPE OF WORK.
 CONTRACTOR IS SUBMITTING NEW SET. NO ADDITIONAL REVIEWS
 ARE TO BE PERFORMED UNDER THIS PERMIT
  
 V. PEREZ
 *6717
2017-04-20 10:38:01SENT TO B09
2017-04-17 07:54:07REVISION GIVEN TO SKENNEDY

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-05-19 Cont ID  
Sent By ccole Date 2017-05-19 Time 11:22 Rev Time 0.00
Received By ccole Date 2017-05-19 Time 11:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-04-21 Cont ID  
Sent By ccole Date 2017-04-21 Time 12:32 Rev Time 0.00
Received By ccole Date 2017-04-21 Time 12:32 Sent To  
Notes
2017-04-21 12:41:241ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES
 REVISION #17040656
 PERMIT #16070262
 4/21/17
  
 1) THE REVISED FLOOR PLAN INDICATES ROOM CONFIGURATION
 CHANGES AND CHANGES IN ROOM IDENTIFICATIONS (SEE FLOOR
 PLAN SUBMITTED UNDER PERMIT #16070262). PLEASE PROVIDE
 MECHANICAL PLANS SHOWING ALL REQUIRED ALTERATIONS TO
 THE EXISTING HVAC SYSTEMS TO ACCOMODATE THE NEW FLOOR
 PLAN LAYOUTS AND CHANGES OF ROOM USES.
  
 2) REFER TO SECTIONS 809.1 & 809.2 FBC-14 EXISTING
 BUILDING CODE AND PROVIDE MINIMUM VENTILATION
 CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE 403.3
 FBC-14 MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES
 THE REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR AND/OR
 EXHAUST AIR.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2017-05-22 Cont ID  
Sent By gjohnson Date 2017-05-22 Time 13:38 Rev Time 0.00
Received By gjohnson Date 2017-05-22 Time 13:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2017-04-25 Cont ID  
Sent By gjohnson Date 2017-04-25 Time 09:19 Rev Time 0.00
Received By vperez Date 2017-04-25 Time 09:19 Sent To  
Notes
***NONE***