Plan Review Details - Permit 17040620
Plan Review Stops For Permit 17040620 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2017-06-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-28 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-28 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2017-06-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-06-15 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-06-12 |
Time |
08:26 |
Sent To |
|
|
Notes |
2017-06-15 10:20:16 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 5TH REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. 4X FEE HAS BEEN ASSESSED. | | F.S. 553.80 (2) (B) | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | 2. PROVIDE TEST REPORT FOR SURFACE BURNING | | CHARACTERISTICS OF BUILDING MATERIALS PER ASTM E-84 FOR | | THE PROPOSED LVT FLOORING. | | FBC 603.1 FLAME SPREAD ? ASTM E-84 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2017-06-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-01 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-01 |
Time |
08:07 |
Sent To |
|
|
Notes |
2017-06-01 08:35:35 | 2014 FBC- BUILDING PLAN REVIEW BUILDING | | W. P. B. PERMIT: 17040620 | | ADD: 780 S. SAPODILLA AVE. SUITE # 214 | | CONT: LOWES HOME CENTERS | | TEL: 561-721-5611 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 4 X FEE HAS BEEN ADDED TO PERMIT!!!!!!! | | ************ 4X FEE NOTICE!!!!! FLORIDA STATUTE | | 553.80(2)(B) ************* WITH RESPECT TO EVALUATION | | OF DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL | | GOVERNMENT FINDS IT NECESSARY, IN ORDER TO ENFORCE | | COMPLIANCE WITH THE FLORIDA BUILDING CODE AND ISSUE A | | PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY THE CODE | | THREE OR MORE TIMES FOR FAILURE TO CORRECT A CODE | | VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH | | REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE | | PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | 4TH REVIEW | | DATE: THURS. JUNE 01/ 2017 | | ACTION: DENIED | | | | THIS REVIEW A SALES BROCHURE FOR SMARTCORE ENGINEERED | | LUXURY FLOORS WAS SUBMITTED. PLEASE SHOW COMPLIANCE | | WITH: | | BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B | | 2014) | | FOR TILE, STONE, MARBLE, WOOD FLOORING AND VINYL | | FLOORING ALL NEED TO HAVE HAD THE SOUND UNDERLAYMENT | | TESTED FLOOR ASSEMBLIES TO THE FOLLOWING STANDARDS AND | | MEET THE QUALIFICATIONS LISTED UNDER EACH OF THE | | STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ NO | | DROPPED CEILING: | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | 1A) 4TH REQUEST. FBC-B 2014 1207.3 STRUCTURE-BORNE | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | 1B) 4TH REQUEST. FBC-B 2014 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 1C) 4TH REQUEST. FLAME SPREAD- FBC-B 2014 603.1. | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-18 |
Time |
07:17 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-05-18 |
Time |
07:01 |
Sent To |
|
|
Notes |
2017-05-18 07:17:53 | 2014 FBC- BUILDING PLAN REVIEW BUILDING | | W. P. B. PERMIT: 17040620 | | ADD: 780 S. SAPODILLA AVE. SUITE # 214 | | CONT: LOWES HOME CENTERS | | TEL: 561-721-5611 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | | | ************ 4X FEE NOTICE!!!!! FLORIDA STATUTE | | 553.80(2)(B) ************* WITH RESPECT TO EVALUATION | | OF DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL | | GOVERNMENT FINDS IT NECESSARY, IN ORDER TO ENFORCE | | COMPLIANCE WITH THE FLORIDA BUILDING CODE AND ISSUE A | | PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY THE CODE | | THREE OR MORE TIMES FOR FAILURE TO CORRECT A CODE | | VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH | | REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE | | PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | 3RD REVIEW | | DATE: THURS. MAY 18/ 2017 | | ACTION: DENIED | | | | THE SUBMITTED TEST REPORTS FOR FLOOR SOUND INSULATION | | SELITBLOCK 2 TEST ASTM E 492-09 & ASTM E 90 BOTH ARE | | CODE COMPLIANT FOR A 6 INCH CONCRETE SLAB. | | MISSING IS THE FLAME SPREAD TESTING REPORT. | | BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B | | 2014) | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | 3RD REQUEST!!!!! C) FLAME SPREAD- FBC-B 2014 603.1. | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | COMPLIED. FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | COMPLIED. FBC-B 2014 1207.2 AIR-BORNE SOUND. WALLS, | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | 90. | | | | | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-04 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-05-04 |
Time |
|
Sent To |
|
|
Notes |
2017-05-04 14:09:14 | 2014 FBC- BUILDING PLAN REVIEW BUILDING | | W. P. B. PERMIT: 17040620 | | ADD: 780 S. SAPODILLA AVE. SUITE # 214 | | CONT: LOWES HOME CENTERS | | TEL: 561-721-5611 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | | | ************ 4X FEE NOTICE!!!!! FLORIDA STATUTE | | 553.80(2)(B) ************* WITH RESPECT TO EVALUATION | | OF DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL | | GOVERNMENT FINDS IT NECESSARY, IN ORDER TO ENFORCE | | COMPLIANCE WITH THE FLORIDA BUILDING CODE AND ISSUE A | | PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY THE CODE | | THREE OR MORE TIMES FOR FAILURE TO CORRECT A CODE | | VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH | | REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE | | PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | 2ND REVIEW | | DATE: THURS. MAY 04/ 2017 | | ACTION: DENIED | | | | THE SUBMITTED TEST REPORTS FOR FLOOR SOUND INSULATION | | SELITBLOCK 2 TEST ASTM E 492-09 & ASTM E 90 BOTH ARE | | FOR DROPPED CEILINGS WITH INSULATION, NOT CODE | | COMPLIANT, THAT IS NOT HOW SOUTH FLORIDA BUILDS | | HIGHRISES. | | NO FLAME SPREAD TESTING SUBMITTED. | | | | BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B | | 2014) | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | B) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-04-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-04-18 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-04-18 |
Time |
10:00 |
Sent To |
|
|
Notes |
2017-04-18 10:07:44 | 2014 FBC- BUILDING PLAN REVIEW BUILDING | | W. P. B. PERMIT: 17040620 | | ADD: 780 S. SAPODILLA AVE. SUITE # 214 | | CONT: LOWES HOME CENTERS | | TEL: 561-721-5611 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: | | ACTION: DENIED | | | | BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B | | 2014) | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | B) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-06-28 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-06-26 |
Time |
13:35 |
Sent To |
|
|
Notes |
2017-06-27 13:35:39 | RESUB ROUTED TO JWITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-06-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-06-15 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-06-08 |
Time |
14:03 |
Sent To |
|
|
Notes |
2017-06-09 14:12:25 | RESUB ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-06-01 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-05-30 |
Time |
10:51 |
Sent To |
|
|
Notes |
2017-05-31 10:52:10 | RESUB ROUTED TO JWITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-05-18 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-05-15 |
Time |
10:50 |
Sent To |
|
|
Notes |
2017-05-16 10:50:30 | RESUB ROUTED TO JWITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-05-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-04 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-04-26 |
Time |
13:07 |
Sent To |
|
|
Notes |
2017-04-27 13:07:31 | RESUB ROUTED TO JWITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-04-18 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-04-13 |
Time |
10:44 |
Sent To |
|
|
Notes |
2017-04-14 10:44:12 | BLDG <5K |
|
|
|