Plan Review Stops For Permit 17040423 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2018-03-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-03-21 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-03-21 |
Time |
11:51 |
Sent To |
I |
|
Notes |
2018-03-21 14:20:19 | APPROVED WITH PROVISO | | THE FIRST FLOOR OF THE GARAGE APARTMENT IS TO BE | | CONVERTED BACK TO NON-HABITABLE STORAGE SPACE. IT IS TO | | REMAIN NON-HABITABLE SPACE, UNTIL SUCH TIME AS PROPER | | PERMITS HAVE BEEN OBTAINED AND REQUIRED INSPECTIONS | | HAVE BEEN APPROVED FOR CONVERSION TO LIVING SPACE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-28 |
Time |
17:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-28 |
Time |
16:23 |
Sent To |
I |
|
Notes |
2017-11-28 17:49:01 | PLAN | | REVIEW COMMENTS | | | | 4TH REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | BASED ON THE RESEARCH THAT I HAVE DONE, IT APPEARS THAT | | THIS STRUCTURE WAS ORIGINALLY A GARAGE APARTMENT BUILT | | IN 1925. THE SECOND FLOOR WAS LIVING SPACE AND THE | | FIRST FLOOR WAS A GARAGE. THE GARAGE HAD A 3 FIXTURE | | BATH ROOM. THERE ARE NOT ANY RECORDS ON FILE WITH THE | | CITY TO INDICATE THAT THE GARAGE WAS CONVERTED TO | | LIVING AREA WITH THE PROPER PERMITS AND INSPECTIONS. | | THERE IS A 4 TIMES THE FEE HOLD NOTE IN THE FILE FOR | | WORKING WITHOUT PERMITS FROM 2016 FOR CONVERTING THE | | GARAGE TO LIVING SPACE. A PERMIT WAS NEVER ATTAINED. | | THE WORK TO THE FIRST FLOOR GARAGE THAT IS SHOWN ON THE | | PLANS THAT WERE SUBMITTED WAS DONE WITHOUT THE PROPER | | PERMITS AND INSPECTIONS. PLEASE BE ADVISED THE | | INSPECTOR MAY REQUIRE PREVIOUSLY COMPLETED WORK TO BE | | MADE ACCESSIBLE AND OPEN FOR INSPECTION OR REQUIRE | | ADDITIONAL DOCUMENTATION FOR ALL CONCEALED WORK | | PREVIOUSLY COMPLETED PURSUANT TO FBC 110 & FBC 117. | | FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | PURPOSES UNTIL APPROVED. | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE | | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN | | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. | | | | NOTE: IN ORDER TO LEGALLY CONVERT THE GARAGE TO LIVING | | SPACE, THE APPROVED PLANS WILL BE REQUIRED TO BE | | REVIEWED BY PALM BEACH COUNTY TO DETERMINE IF ANY | | IMPACT FEES ARE DUE. | | | | DENIED BY BUILDING - THE COMMENTS FROM THE LAST REVIEW | | HAVE NOT BEEN ADDRESSED. PLEASE ADDRESS THE ITEMS NOTED | | BELOW: | | | | | | 1) SUBMIT TWO SETS OF ARCHITECTURAL DRAWINGS THAT SHOW | | THE EXISTING FLOOR PLANS AND THE PROPOSED FLOOR PLANS. | | FBC 107.2.1 | | | | 2) PROVIDE THE COMPLETE SCOPE OF WORK THAT IS PROPOSED | | TO BE DONE ON THE FLOOR PLANS. FBC 107.2.1 | | | | 3) THE ENERGY FORM R405-2014 IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER/AGENT. FBC ENERGY CONSERVATION | | SECTION R103.1.1.2 | | | | 4) THE ENERGY FORM R405-2014 CONTAINS ERRORS. THE FORM | | HAS ONE BEDROOM AND THERE ARE 2 BEDROOMS. THERE IS NO | | WHOLE HOUSE FAN SHOWN ON THE PLANS. THE FORM SPECIFIES | | TWO DUCTLESS A/C UNITS AND ONE DUCTED SPLIT A/C SYSTEM. | | THE PLANS SHOW TWO DUCTED SPLIT A/C SYSTEMS AND ONE | | WINDOW UNIT. PLEASE REVIEW THE FORM AND MAKE | | CORRECTIONS SO THAT THE PLANS AND FORM MATCH. FBC | | ENERGY CONSERVATION SECTION R405 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-10-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-10-30 |
Time |
18:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-10-30 |
Time |
18:22 |
Sent To |
|
|
Notes |
2017-10-30 18:58:45 | PLAN | | REVIEW COMMENTS | | | | 3RD REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT TWO SETS OF ARCHITECTURAL DRAWINGS THAT SHOW | | THE EXISTING FLOOR PLANS AND THE PROPOSED FLOOR PLANS. | | FBC 107.2.1 | | | | 2) PROVIDE THE COMPLETE SCOPE OF WORK THAT IS PROPOSED | | TO BE DONE ON THE FLOOR PLANS. FBC 107.2.1 | | | | 3) THE ENERGY FORM R405-2014 IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER/AGENT. FBC ENERGY CONSERVATION | | SECTION R103.1.1.2 | | | | 4) THE ENERGY FORM R405-2014 CONTAINS ERRORS. THE FORM | | HAS ONE BEDROOM AND THERE ARE 2 BEDROOMS. THERE IS NO | | WHOLE HOUSE FAN SHOWN ON THE PLANS. THE FORM SPECIFIES | | TWO DUCTLESS A/C UNITS AND ONE DUCTED SPLIT A/C SYSTEM. | | THE PLANS SHOW TWO DUCTED SPLIT A/C SYSTEMS AND ONE | | WINDOW UNIT. PLEASE REVIEW THE FORM AND MAKE | | CORRECTIONS SO THAT THE PLANS AND FORM MATCH. FBC | | ENERGY CONSERVATION SECTION R405 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-08-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-01 |
Time |
18:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-01 |
Time |
17:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-05-10 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-05-10 |
Time |
13:07 |
Sent To |
M |
|
Notes |
2017-05-10 14:03:27 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) NO STRUCTURAL PLANS WERE SUBMITTED. SUBMIT TWO SETS | | OF CONSTRUCTION DOCUMENTS THAT LISTS THE COMPLETE SCOPE | | OF WORK THAT IS PROPOSED TO BE PREFORMED. FBC 107.2.1 | | | | 2) THE VALUATION FOR THE MECHANICAL, ELECTRICAL AND | | PLUMBING WORK THAT IS SHOWN ON THE PLANS OF $2,500.00 | | IS VERY LOW. PROVIDE AN ACCURATE VALUATION FOR THE | | PROPOSED WORK. FBC 109.3 BUILDING PERMIT VALUATION. FOR | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-03-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-03-20 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-20 |
Time |
15:05 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-04-24 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-04-24 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-04-24 |
Time |
09:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2017-11-28 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-11-28 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-11-28 |
Time |
08:01 |
Sent To |
|
|
Notes |
2017-11-28 08:09:39 | PROVISO: | | | | 1. PROVIDE APPROVED, REVISED GAS RISER DIAGRAM SHOWING | | TYPE OF PIPING AND SIZING ALSO INDICATE NEW AND | | EXISTING PIPING ON PLAN SHALL BE ON JOBSITE FOR FIRST | | INSPECTION. | | 2. THE WATER HEATER ON THE EXTERIOR OF THE BUILDING WAS | | NOT SHOWN ON ANY PREVIOUS PERMITS SO IT SHALL COMPLY | | WITH EXISTING PLUMBING CODE FBC RES 2014 AND BE LISTED | | TO BE INSTALLED IN WET LOCATIONS PLEASE PLACE NOTE ON | | PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2017-10-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-29 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-10-29 |
Time |
10:13 |
Sent To |
|
|
Notes |
2017-10-29 11:16:58 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | GAS COMMENTS: | | | | 1. SHT. P-3 SHOWS A KITCHEN WITH SINK AND GAS STOVE ALL | | OTHER PLAN SHEETS SHOW ONLY A LIVING ROOM PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 2. THE MECHANICAL AND ELECTRICAL SHEETS SHOW A WATER | | HEATER IN THE LAUNDRY ROOM THE PLUMBING PLANS DO NOT | | SHOW IT CONNECTED IS THIS WATER HEATER BEING ELIMINATED | | REMOVE IT FROM THE PLAN OR PUT A NOTE ON THE PLUMBING | | SHEETS. PER WPB AMEND TO FBC 107.2.1 | | | | 3. THE KITCHEN SINK AND GAS STOVE ARE SHOWN ON THE | | PLUMBING FLOOR PLAN SHT. P-3 BUT THEIR NOT SHOWN ON THE | | RISERS SHT P-4 IF THEY ARE BEING REMOVE PLACE NOTE ON | | PLAN AND SHOW CAPS ON THE RISERS. PER WPB AMEND TO FBC | | 107.2.1 | | | | 4. SHT. P-3 AND E-1 SHOW 2 BEDROOMS ON THE FIRST FLOOR | | THE REST OF THE PLAN SHOWS A STORAGE ROOM IN THE SAME | | LOCATION PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 5. THE WATER HEATER ON THE EXTERIOR OF THE BUILDING WAS | | NOT SHOWN ON ANY PREVIOUS PERMITS SO IT SHALL COMPLY | | WITH EXISTING PLUMBING CODE FBC RES 2014 AND BE LISTED | | TO BE INSTALLED IN WET LOCATIONS PLEASE PLACE NOTE ON | | PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2017-07-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-19 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-19 |
Time |
16:41 |
Sent To |
|
|
Notes |
2017-07-19 16:54:15 | 2ND REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: | | | | 1. THE FIRST BRANCH DOWN STREAM OF THE FIRST WATER | | HEATER HAS 2 DIFFERENT SIZES ON IT 1' AND 11/4" PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 2. WHAT TYPE AND SIZE IS THE NEW PIPING FROM METER TO | | EXISTING PIPING GALV PIPING IS NOT ALLOWED UNDER GROUND | | . PER FBC FG 404.11 | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-04-27 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-27 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-04-27 |
Time |
17:36 |
Sent To |
|
|
Notes |
2017-04-27 17:40:15 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | PSI. | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | SEC. 502 THRU 505. | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2018-05-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-05-02 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-04-20 |
Time |
14:26 |
Sent To |
I |
|
Notes |
2018-04-23 14:26:15 | RESUB ROUTED TO HMOSER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2018-03-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-03-21 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-03-12 |
Time |
15:30 |
Sent To |
|
|
Notes |
2018-03-13 15:30:39 | RESUB ROUTED TO HMOSER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-11-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-28 |
Time |
17:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-22 |
Time |
15:13 |
Sent To |
|
|
Notes |
2017-11-22 15:14:03 | RESUB ROUTED TO GJOHNSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-10-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-10-30 |
Time |
18:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-10-13 |
Time |
10:21 |
Sent To |
|
|
Notes |
2017-10-16 10:21:35 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-08-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-08-06 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-06-30 |
Time |
09:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-05-18 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-05-18 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-04-10 |
Time |
12:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
N |
Date |
2018-05-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-05-02 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-05-02 |
Time |
13:13 |
Sent To |
|
|
Notes |
2018-05-02 13:17:00 | THE FIRST FLOOR OF THE GARAGE APARTMENT IS BEING | | CHANGED BACK TO STORAGE SPACE, NO HABITABLE SPACE IS | | BEING ADDED. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-28 |
Time |
18:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-28 |
Time |
18:36 |
Sent To |
|
|
Notes |
2017-11-28 18:41:20 | THE PLANS SHOW A LIVING ROOM WHERE THE GARAGE ONCE WAS. | | THEREFORE, BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. UPON | | APPROVAL, ONE SET OF PLANS SHALL BE SIGNED OUT AND | | SUBMITTED TO PALM BEACH COUNTY FOR AN IMPACT FEE | | REVIEW. THE PLANS WITH THE IMPACT FEE STAMP AND A COPY | | OF THE PAID RECEIPT MUST BE RETURNED TO THE CITY | | BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN BE | | ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY IMPACT | | FEES AT (561) 233-5025. | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
N |
Date |
2017-08-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-08-01 |
Time |
18:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-08-01 |
Time |
18:43 |
Sent To |
|
|
Notes |
2017-08-01 18:44:08 | NO NEW LIVING AREA IS BEING ADDED. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-05-10 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-05-10 |
Time |
14:04 |
Sent To |
|
|
Notes |
2017-05-10 14:31:31 | IT IS NOT CLEAR FROM THE DOCUMENTS THAT WERE SUBMIT | | WHETHER OR NOT ANY LIVING SPACE HAS BEEN ADDED. | | INDICATE ON THE PLANS IF ANY STORAGE OR OTHER | | NON-HABITABLE SPACES WILL BE CONVERTED TO LIVING SPACE | | AND IF SO PROVIDE AREA TABULATIONS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2018-04-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-04-24 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-04-24 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-03-19 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-03-19 |
Time |
14:15 |
Sent To |
|
|
Notes |
2018-03-19 14:34:03 | PLAN DENIED | | 1) REFER TO SECTION R1602.2.4 AIR HANDLING | | UNITS 2014 RESIDENTIAL CODE. | | 2) REFER TO SECTION M1602.4 BALANCED | | RETURN AIR 2014 RESIDENTIAL CODE | | 3) PROVIDE AHRI WITH PLAN. | | 4) PROVIDE COMPLETE MODEL NUMBERS | | OF EQUIPMENT (AIR HANDLER, COALS AND | | CONDENSERS) PROVIDE SEER ON EQUIPMENT SCHEDULE. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-08-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-08-06 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-08-06 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-05-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-05-15 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-05-15 |
Time |
09:02 |
Sent To |
Z |
|
Notes |
2017-05-15 10:12:10 | PLAN DENIED | | 1) PROVIDE EQUIPMENT SCHEDULE ON PLAN. PER | | SECTION 107 FBC | | 2) PROVIDE ENERGY CALCULATION WITH PLANS. PER | | SECTION R403.6.1 2014 FLORIDA ENERGY CODE. | | 3) REFER TO SECTION R403.2.4 AIR HANDLING UNITS. | | 2014 FLORIDA ENERGY CODE | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2017-11-28 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-11-28 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-11-28 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2017-10-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-29 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-10-29 |
Time |
09:47 |
Sent To |
|
|
Notes |
2017-10-29 10:13:14 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. SHT. P-3 SHOWS A KITCHEN WITH SINK AND GAS STOVE ALL | | OTHER PLAN SHEETS SHOW ONLY A LIVING ROOM PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 2. THE MECHANICAL AND ELECTRICAL SHEETS SHOW A WATER | | HEATER IN THE LAUNDRY ROOM THE PLUMBING PLANS DO NOT | | SHOW IT CONNECTED IS THIS WATER HEATER BEING ELIMINATED | | REMOVE IT FROM THE PLAN OR PUT A NOTE ON THE PLUMBING | | SHEETS. PER WPB AMEND TO FBC 107.2.1 | | | | 3. THE KITCHEN SINK AND GAS STOVE ARE SHOWN ON THE | | PLUMBING FLOOR PLAN SHT. P-3 BUT THEIR NOT SHOWN ON THE | | RISERS SHT P-4 IF THEY ARE BEING REMOVE PLACE NOTE ON | | PLAN AND SHOW CAPS ON THE RISERS. PER WPB AMEND TO FBC | | 107.2.1 | | | | 4. SHT. P-3 AND E-1 SHOW 2 BEDROOMS ON THE FIRST FLOOR | | THE REST OF THE PLAN SHOWS A STORAGE ROOM IN THE SAME | | LOCATION PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 5. THE WATER HEATER ON THE EXTERIOR OF THE BUILDING WAS | | NOT SHOWN ON ANY PREVIOUS PERMITS SO IT SHALL COMPLY | | WITH EXISTING PLUMBING CODE FBC RES 2014 AND BE LISTED | | TO BE INSTALLED IN WET LOCATIONS PLEASE PLACE NOTE ON | | PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-07-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-19 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-19 |
Time |
09:41 |
Sent To |
|
|
Notes |
2017-07-19 16:40:12 | 2ND REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: PREVIOUS COMMENT HAS NOT COMPLIED | | 2ND REQUEST | | | | | | 2. THE VALUATION OF THE PROJECT IS LOW PLEASE PROVIDE A | | CONTRACT OR PROPOSAL FOR ALL WORK BEING PERMITTED. PER | | WPB AMEND TO FBC 109.3 BUILDING PERMIT VALUATIONS. IF, | | IN THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED | | VALUATION OF | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | BUILDING OFFICIAL. | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-04-27 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-27 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-04-27 |
Time |
15:26 |
Sent To |
|
|
Notes |
2017-04-27 17:35:50 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. YOUR KEY NOTES ARE UNCLEAR ON WHICH PIPING IS BEING | | REPLACED PLEASE PROVIDE A DETAILED SCOPE OF PLUMBING | | WORK BEING DONE FOR ALL WATER ,SANITARY AND GAS. PER | | WPB AMEND TO FBC 107.2.1 | | | | 2. THE VALUATION OF THE PROJECT IS LOW PLEASE PROVIDE A | | CONTRACT OR PROPOSAL FOR ALL WORK BEING PERMITTED. PER | | WPB AMEND TO FBC 109.3 BUILDING PERMIT VALUATIONS. IF, | | IN THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED | | VALUATION OF | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | BUILDING OFFICIAL. | | | | 3. PLEASE PROVIDE AN EXISTING PLAN FOR FIRST AND SECOND | | FLOOR. PER WPB AMEND TO FBC 107.2.1 | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-10-26 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2017-10-26 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2017-10-18 |
Time |
10:53 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2017-07-06 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-07-06 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-07-06 |
Time |
14:12 |
Sent To |
|
|
Notes |
2017-07-06 15:52:44 | 7/6/17- FAILED | | | | ENTIRE UNIT MUST BE ACCESSIBLE FROM THE INTERIOR | | DUPLEX IS NOT PERMITTED IN THIS ZONE | | CANNOT HAVE TWO(2)LIVING ROOMS | | CANNOT HAVE TWO(2)SEPORATE ELECTRICAL HOOKUPS | | | | | | PLEASE CONTACT | | NATHAN WIRA- ZONING TECHNICIAN | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING | | DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST. | | WEST PALM BEACH, FL 33402 | | OFFICE HOURS: M-F 8AM - 5PM | | (561)822-1442 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-05-18 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-05-16 |
Time |
16:58 |
Sent To |
I |
|
Notes |
2017-05-18 10:49:07 | 5/18/17- FAILED | | | | DUPLEX IS NOT PERMITTED IN THIS ZONE. | | | | | | PLEASE CONTACT | | NATHAN WIRA- ZONING TECHNICIAN | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING | | DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST. | | WEST PALM BEACH, FL 33402 | | OFFICE HOURS: M-F 8AM - 5PM | | (561)822-1442 | | [email protected] | | |
|
|