Plan Review Details - Permit 17040397
Plan Review Stops For Permit 17040397
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2017-07-21 Cont ID  
Sent By cthroop Date 2017-07-21 Time 08:26 Rev Time 0.00
Received By cthroop Date 2017-07-21 Time 08:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2017-07-05 Cont ID  
Sent By cthroop Date 2017-07-05 Time 11:01 Rev Time 0.00
Received By cthroop Date 2017-07-05 Time 08:16 Sent To  
Notes
2017-07-05 11:06:10BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 3RD REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. 4X FEE TO BE ASSESSED AT FINAL REVIEW.
 2. DESIGNER OF RECORD OR ELECTRICAL CONTRACTOR TO SIGN
 AND SEAL ELECTRICAL PLAN.
 3. REFER TO SCOPE OF WORK, PLAN PAGE (FLOOR PLAN PG. 1
 OF 2) - ADD "INSTALL 4 FLOOD VENTS IN ATTACHED GARAGE"
 AND "RAISE MECHANICAL EQUIPMENT TO 8.68' NGVD".
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-06-20 Cont ID  
Sent By cthroop Date 2017-06-20 Time 08:07 Rev Time 0.00
Received By cthroop Date 2017-06-16 Time 10:14 Sent To  
Notes
2017-06-20 08:30:31BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SQUARE FOOTAGE OF ATTACHED GARAGE STATED AS 300 SQ.
 FT. (SEE ELEVATION CERTIFCATE A9 A). THIS SHOULD BE 464
 SQ. FT.
 2. SCOPE OF WORK INCREASED TO INCLUDE THE INSTALLATION
 OF FLOOD VENTS.
 3. IF ENGINEERED VENTS ARE INSTALLED, PROVIDE DESIGN
 CERTIFIED BY A REGISTERED DESIGN PROFESSIONAL OR AN
 EVALUATION REPORT ISSUED BY THE INTERNATIONAL CODE
 COUNCIL (ICC) EVALUATION SERVICE, INC.
 4. IF NON-ENGINEERED OPENINGS ARE INSTALLED, REFER TO
 FEMA'S NON-ENGINEERED OPENING GUIDE, VOLUME 1 DATED
 JANUARY 2015.
 5. LOCATION OF PROPOSED VENTS ARE ON ONE WALL. REFER TO
 FEMA'S OPENINGS IN FOUNDATION WALLS AND WALLS OF
 ENCLOSURES TECHNICAL BULLENTIN 1 DATE AUGUST 2008. IT
 IS RECOMMENDED THAT OPENINGS BE REASONBLY DISTRIBUTED
 AROUND THE PEREMITER OF THE ENCLOSED AREA UNLESS THERE
 IS CLEAR JUSTIFICATION FOR PUTTING ALL OPENINGS ON JUST
 ONE OR TWO SIDES. THERE APPEARS TO BE AN AREA LOCATED
 ADJACENT TO THE FOYER EXTERIOR DOOR TO LOCATE AT LEAST
 ONE VENT.
 6. FINAL ELEVATION CERTIFCATE REQUIRED PRIOR TO FINAL
 INSPECTION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-04-24 Cont ID  
Sent By cthroop Date 2017-04-24 Time 13:36 Rev Time 0.00
Received By cthroop Date 2017-04-24 Time 11:34 Sent To  
Notes
2017-04-24 13:46:03BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. 4X FEE TO BE APPLIED FOR WORK WITHOUT PERMIT.
 2. PROVIDE SITE PLAN. LOCATE BUILDING ON SITE PLAN WITH
 REQUIRED SETBACKS.
 3. ROOFING PERMIT REQUIRED.
 4. PROPERTY IS LOCATED IN FLOOD ZONE A-5. BASE FLOOD
 ELEVATION IS 7.0 NGVD. AS OF OCTOBER 5, 2016, A
 FREEBOARD OF 12 INCHES SHALL BE REQUIRED. DESIGN FLOOD
 ELEVATION SHALL BE A MINUMUM OF 8.0 FEET NGVD.
 5. PROVIDE UPDATED ELEVATION CERTIFICATE.
 6. PROVIDE UPDATED SURVEY.
  
 THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS
 A5 WITH A BASE FLOOD ELEVATION (BFE) OF 7 FEET. THE
 CITY OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES A
 FREEBOARD OF 12 INCHES, REQUIRING THE DESIGN FLOOD
 ELEVATION (DFE) TO BE 8. 0 FEET. PLEASE NOTE THIS
 INFORMATION ON YOUR PLANS.
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
 NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS
 SITE ARE REQUIRED TO BE AT OR ABOVE 8.0 FEET NGVD.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
 2.2. CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT
 THAT THE BUILDING IS DESIGNED IN ACCORDANCE WITH ASCE
 24, INCLUDING THAT THE PILE OR COLUMN FOUNDATION AND
 BUILDING OR STRUCTURE TO BE ATTACHED THERETO IS
 DESIGNED TO BE ANCHORED TO RESIST FLOTATION, COLLAPSE
 AND LATERAL MOVEMENT DUE TO THE EFFECTS OF WIND AND
 FLOOD LOADS ACTING SIMULTANEOUSLY ON ALL BUILDING
 COMPONENTS, AND OTHER LOAD REQUIREMENTS OF CHAPTER 16.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2017-07-19 Cont ID  
Sent By jpearson Date 2017-07-19 Time 12:26 Rev Time 0.00
Received By jpearson Date 2017-07-19 Time 12:26 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2017-06-28 Cont ID  
Sent By jpearson Date 2017-06-28 Time 10:01 Rev Time 0.00
Received By jpearson Date 2017-06-28 Time 10:01 Sent To B
Notes
2017-06-28 10:06:08CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW COMMENTS:
  
 1. ALL CORRECTIONS WERE SUFFICIENT. HOWEVER, THE PLAN
 IS NOT SIGNED AND SEALED. PLAN IS REQUIRED TO BE SIGNED
 AND SEALED BY A DESIGN PROFESSIONAL OR THE ELECTRICAL
 CONTRACTOR QUALIFIER. FS 471.003(2)(H); 471.025
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-06-02 Cont ID  
Sent By jpearson Date 2017-06-02 Time 09:47 Rev Time 0.00
Received By jpearson Date 2017-06-02 Time 09:47 Sent To  
Notes
2017-06-02 10:00:06CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 REVIEW COMMENTS:
  
 1. PROVIDE CORRECTION FOR EXTERIOR LIGHTS. FOR DWELLING
 UNITS, ATTACHED GARAGES, AND DETACHED GARAGES WITH
 ELECTRIC POWER, AT LEAST ONE WALL SWITCH-CONTROLLED
 LIGHTING OUTLET SHALL BE INSTALLED ON THE EXTERIOR SIDE
 OF OUTDOOR ENTRANCES OR EXITS WITH GRADE LEVEL ACCESS.
 NEC 210.70(A)(2)(B), FBC RE3903.3
 2. PROVIDE CORRECTION FOR AFCI PROTECTION. ALL
 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH
 CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
 HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI
 PROTECTION. NEC 210.12, FBC RE3902.12
 3. PROVIDE CORRECTION FOR MASTER CLOSET LIGHTING.
 LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS AND
 PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE
 PERMITTED IN CLOSETS. NEC 410.16(B), FBC RE4003.12
 4. PROVIDE CORRECTION FOR LIGHT OVER JACUZZI. LIGHTING
 IN BATHTUB OR SHOWER AREAS SHALL BE SUITABLE FOR DAMP
 OR WET LOCATIONS AS REQUIRED. NEC 410.10(A), FBC
 RE4003.11
 5. PROVIDE CORRECTION FOR POWER TO JACUZZI.
 HYDROMASSAGE TUBS AND THEIR ASSOCIATED EQUIPMENT SHALL
 BE ON AN INDIVIDUAL BRANCH CIRCUIT(S) AND PROTECTED AND
 PROTECTED BY A READILY-ACCESSIBLE GFCI. NEC 680.71, FBC
 RE4209.1
 6. PROVIDE CORRECTION FOR MASTER BATH OUTLETS. A GFCI
 PROTECTED OUTLET IS REQUIRED WITHIN 36" OF EACH BASIN.
 NEC 210.52(D), FBC RE3901.6
 7. PROVIDE CORRECTION FOR KITCHEN PENINSULA. A GFCI
 PROTECTED OUTLET IS REQUIRED FOR THE COUNTER SPACE ON A
 PENINSULA. NEC 201.52(C)(3), FBC RE3901.4.3
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-04-21 Cont ID  
Sent By vperez Date 2017-04-21 Time 11:43 Rev Time 0.00
Received By vperez Date 2017-04-21 Time 11:43 Sent To  
Notes
2017-04-21 11:43:53ADDRESS ZONING COMMENTS FOR AN ELECTRICAL APPROVAL. FBC
 107.3.5
 V. PEREZ
 *6717

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-07-21 Cont ID  
Sent By cthroop Date 2017-07-21 Time 08:26 Rev Time 0.00
Received By cthroop Date 2017-07-17 Time 08:49 Sent To  
Notes
2017-07-19 08:49:56RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-07-05 Cont ID  
Sent By cthroop Date 2017-07-05 Time 11:01 Rev Time 0.00
Received By cthroop Date 2017-06-22 Time 15:57 Sent To  
Notes
2017-06-23 15:57:42R06

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-06-20 Cont ID  
Sent By cthroop Date 2017-06-20 Time 08:07 Rev Time 0.00
Received By cthroop Date 2017-05-23 Time 14:15 Sent To  
Notes
2017-05-24 14:16:07R18

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-04-25 Cont ID  
Sent By hmoser Date 2017-04-25 Time 17:29 Rev Time 0.00
Received By hmoser Date 2017-04-10 Time 14:58 Sent To  
Notes
2017-04-11 14:58:54R20

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2017-06-14 Cont ID  
Sent By hmoser Date 2017-06-14 Time 15:22 Rev Time 0.00
Received By hmoser Date 2017-06-14 Time 15:22 Sent To  
Notes
2017-06-14 15:24:16NO AIR CONDITIONING WORK BEING DON AT THIS TIME
 HM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-04-25 Cont ID  
Sent By hmoser Date 2017-04-25 Time 17:29 Rev Time 0.00
Received By hmoser Date 2017-04-25 Time 17:07 Sent To  
Notes
2017-04-25 17:29:08PLAN DENIED
 NO MECHANICAL PLAN SUBMITTED HM.
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status N Date 2021-07-22 Cont ID  
Sent By shill Date 2021-07-22 Time 05:39 Rev Time 0.00
Received By shill Date 2021-07-22 Time 05:39 Sent To  
Notes
2021-07-22 05:40:24NOT A SUBSTANTIAL IMPROVEMENT
 2016 STRUCTURE VALUE PER PAPA $154,193; VALUE OF WORK
 BEING PERFORMED CUMULATIVE 5 YEARS (NO OTHER PERMITS) =
 $20,000
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2017-07-05 Cont ID  
Sent By cthroop Date 2017-07-05 Time 11:06 Rev Time 0.00
Received By cthroop Date 2017-07-05 Time 11:06 Sent To  
Notes
2017-07-05 11:07:19UPDATED ELEVATION CERTIFICATE REQUIRED AT BLDG. FINAL.

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2017-04-24 Cont ID  
Sent By cthroop Date 2017-04-24 Time 13:47 Rev Time 0.00
Received By cthroop Date 2017-04-24 Time 13:47 Sent To  
Notes
2017-04-24 13:47:54 
 BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. FLOOD ZONE A-5. AS OF OCTOBER 5, 2017 THE BASE FLOOD
 ELEVATION OF FLOOD ZONE A-5 IS 7.5 NGVD. DESIGN FLOOD
 ELEVATION SHALL BE A MINUMUM OF 8.0 FEET NGVD.
 2. PROVIDE UPDATED ELEVATION CERTIFICATE.
 3. PROVIDE UPDATED SURVEY.
  
 THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS
 A5 WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. 6 INCHES.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE)
 REQUIRES AN ADDITIONAL 6 INCHES OF FREEBOARD REQUIRING
 THE DESIGN FLOOD ELEVATION (DFE) TO BE 8. 0 FEET.
 PLEASE NOTE THIS INFORMATION ON YOUR PLANS.
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
 NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS
 SITE ARE REQUIRED TO BE AT OR ABOVE 8.0 FEET NGVD.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
 2.2. CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT
 THAT THE BUILDING IS DESIGNED IN ACCORDANCE WITH ASCE
 24, INCLUDING THAT THE PILE OR COLUMN FOUNDATION AND
 BUILDING OR STRUCTURE TO BE ATTACHED THERETO IS
 DESIGNED TO BE ANCHORED TO RESIST FLOTATION, COLLAPSE
 AND LATERAL MOVEMENT DUE TO THE EFFECTS OF WIND AND
 FLOOD LOADS ACTING SIMULTANEOUSLY ON ALL BUILDING
 COMPONENTS, AND OTHER LOAD REQUIREMENTS OF CHAPTER 16.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-06-26 Cont ID  
Sent By gjohnson Date 2017-06-26 Time 18:26 Rev Time 0.00
Received By gjohnson Date 2017-06-26 Time 18:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-06-05 Cont ID  
Sent By gjohnson Date 2017-06-05 Time 16:37 Rev Time 0.00
Received By gjohnson Date 2017-06-05 Time 15:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-04-24 Cont ID  
Sent By gjohnson Date 2017-04-24 Time 16:38 Rev Time 0.00
Received By gjohnson Date 2017-04-24 Time 16:38 Sent To  
Notes
2017-04-24 16:56:331ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. MASTER BATH SHOWER ON RISER IS NOT SHOWN ON VENTED
 LINE IT SHOULD CONNECT TO THE WET VENT OF MASTERBATH
 AND BATH #3. PER FBC RES P3108.1
  
 2. WASHING MACHINE TRAP AND STAND PIPE SHALL BE MIN OF
 2". PER FBC RES TABLE P3201.7
  
  
 FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT
 THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL
 COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2017-06-20 Cont ID  
Sent By cthroop Date 2017-06-20 Time 08:06 Rev Time 0.00
Received By cthroop Date 2017-06-16 Time 10:14 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2017-04-24 Cont ID  
Sent By cthroop Date 2017-04-24 Time 13:32 Rev Time 0.00
Received By cthroop Date 2017-04-24 Time 13:32 Sent To  
Notes
2017-04-24 13:34:18BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOF SYSTEM
 COMPONENETS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2017-06-28 Time   Rev Time 0.00
Received By   Date 2017-06-28 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-06-08 Cont ID  
Sent By awooten Date 2017-06-08 Time 14:22 Rev Time 0.00
Received By awooten Date 2017-06-07 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2017-04-20 Time   Rev Time  
Received By   Date 2017-04-20 Time   Sent To  
Notes
2017-04-20 10:02:37***********************ZONING
 REVIEW****************************
  
 DOES THE SCOPE OF THE REMODELING CHANGE THE BUILDING
 FOOTPRINT?
  
 PLEASE INDICATE THE LOCATION OF THE GAZEBO, SQUARE
 FOOTAGE AND SETBACKS FROM THE PROPERTYLINES ON A
 SURVEY.
  
 ACCESSORY STRUCTURES IN RESIDENTIAL DISTRICTS.
  
 (1) MAXIMUM SQUARE FOOTAGE. THE TOTAL FLOOR AREA OF ALL
 ROOFED ACCESSORY BUILDINGS ON A PROPERTY SHALL NOT
 EXCEED 75 PERCENT OF THE GROSS FLOOR AREA OF THE
 PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF 1,000
 SQUARE FEET.
  
 (2) SETBACKS.
  
 FRONT: 25 FEET.
  
 SIDE: FIVE FEET FROM THE LOT LINES.
  
 REAR: FIVE FEET MINIMUM OR 15 FEET FROM THE CENTERLINE
 OF THE ALLEY TO A GARAGE DOOR FACING THE ALLEY,
 WHICHEVER IS GREATER.
  
 PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 561-822-1449
 [email protected]