2017-04-17 18:52:15 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- SPECIFY SIZE AND TYPE OF EXISTING WINDOWS TO BE | | REPLACED TO VERIFY COMPLIANCE WITH EGRESS REQUIREMENTS. | | SEC. 704 FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | | 2- SPECIFY SIZE OF EXISTING FRENCH DOORS TO BE REPLACED | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 3- CLEARLY SPECIFY SIZE OF WINDOW MULLIONS TO VERIFY | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301.1 | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 4- CLEARLY MARK WHICH ARE THE WINDOWS TO BE REPLACED. | | HIGHLIGHTED WINDOWS ON THE PLANS SUBMITTED DON'T ADD UP | | TO 23 WINDOWS AS SPECIFIED ON THE PERMIT APPLICATION. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS AND | | CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC. | | 109.3 CITY AMENDMENTS. UPDATE VALUATION AS REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2017-05-01 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-04-12 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-05-01 |
Time |
14:02 |
Sent To |
B |
|
Notes |
2017-05-01 14:02:59 | 5/1/2017 - APPLICANT PROVIDED UPDATED PRODUCT APPROVALS | | TO MATCH CONDITIONS OF HPB CASE NO. 17-21. DLE | 2017-04-12 15:52:26 | 4/12/17 - APPLICANT RECIEVED LEVEL 2 APPROVAL TO | | REPLACE EXISTING WOOD WINDOWS (WHICH WERE PROVEN BEYOND | | REPAIR), BUT MUST USE ALUMINUM IMPACT PRODUCTS. VINYL | | OR PVC WINDOWS ARE NOT PERMITTED IN HISTORIC DISTRICTS | | WITHOUT HISTORIC PRESERVATION BOARD APPROVAL. PLEASE | | REVISE PRODUCT APPROVALS TO AN ALUMINUM PRODUCT TO PASS | | AT PERMIT LEVEL. DLE | 2017-04-11 16:22:15 | ROUTED TO DESIREE ESTABROOK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-05-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-05-02 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-05-02 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-04-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-17 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-10 |
Time |
12:15 |
Sent To |
|
|
Notes |
2017-04-11 12:16:03 | ROUTED TO HISTORIC VIA ZONING INBOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |