Plan Review Details - Permit 17040313
Plan Review Stops For Permit 17040313 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-04-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-12 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-12 |
Time |
13:25 |
Sent To |
|
|
Notes |
2017-04-12 13:26:54 | YAILEN CALLED TO SAY THEY WILL USE SYSTEM W58 FOR ALL | | ROOF ZONES. | | W58 DESIGN PRESSURES IS -105.0 P.S.F. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-04-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-12 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-12 |
Time |
08:43 |
Sent To |
|
|
Notes |
2017-04-12 09:07:33 | RE-ROOF SECOND BUILDING REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- FLORIDA PRODUCT APPROVAL FL2533-R17 SUBMITTED: THE | | DESIGN PRESSURES FOR THE SELECTED ASSEMBLY W-57 ARE | | -75.0. THE DESIGN PRESSURES FOR THE CORNER AREAS OF | | THIS BUILDING ARE HIGHER. NEED TO SELECT ANOTHER | | ASSEMBLY THAT MEETS THE DESIGN PRESSURES FOR ALL ROOF | | ZONES OR NEED TO PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS AS REQUIRED BY NOTE #8 ON PAGE 2 OF 57 TO | | MEET THE DESIGN PRESSURES FOR THE CORNER AREAS. NEED | | THE CALCULATIONS TO COMPLY WITH THE DESIGN PRESSURES | | REQUIRED BY SEC. 1609.1 FBC, 5TH EDITION (2014). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-04-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-10 |
Time |
17:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-10 |
Time |
17:21 |
Sent To |
|
|
Notes |
2017-04-10 17:57:18 | RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- FLORIDA PRODUCT APPROVAL FL2533-R11 SUBMITTED IS TOO | | OLD. THIS PRODUCT APPROVAL HAVE BEING REVISED SEVERAL | | TIMES AND THE SELECTED ASSEMBLY W-52 IS NO LONGER THE | | SAME. THE CURRENT FLORIDA PRODUCT APPROVAL IS | | FL2533-R-17. PROVIDE CURRENT FLORIDA PRODUCT APPROVAL | | AND MARK PROPOSED ASSEMBLY TO BE INSTALLED TO VERIFY | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. 1609.1 | | FBC, 5TH EDITION (2014). | | | | 2- THIS IS A VERY LARGE BUILDING. THERE ARE SEVERAL | | FLAT ROOFS IN THIS BUILDING. PROVIDE SKETCH SHOWING | | LOCATION AND DIMENSIONS OF THE FLAT AREA TO BE | | RE-ROOFED. SEC. 107.2.1 AND SEC. 109.3 CITY AMENDMENTS | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-04-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-12 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-12 |
Time |
13:23 |
Sent To |
|
|
Notes |
2017-04-12 13:25:18 | YAILEN CALLED TO SAY THEY WILL USE SYSTEM W58 FOR ALL | | ROOF ZONES. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-04-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-12 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-12 |
Time |
08:42 |
Sent To |
|
|
Notes |
2017-04-12 08:43:36 | RECEIVED E-MAIL FROM YAILEN ENRIQUEZ. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-04-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-10 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-07 |
Time |
09:38 |
Sent To |
|
|
Notes |
2017-04-10 09:38:58 | JGOMEZ'S DESK |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |